현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정 (The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF

4전극 전기비저항 탐사장비의 개발 및 검증 (Development and Verification of 4-Electrode Resistivity Probe)

  • 김준한;윤형구;정순혁;이종섭
    • 대한토목학회논문집
    • /
    • 제29권3C호
    • /
    • pp.127-136
    • /
    • 2009
  • 본 연구의 목적은 포화지반의 전기적 특성파악을 위한 4전극 전기비저항 프로브(4-Electrode Resistivity Probe: 4ERP)의 개발과 검증이다. 4ERP는 웨너 배열을 적용하여 전극에서 분극작용 없이 전기비저항을 산정할 수 있도록 쐐기형과 평면형으로 제작되었다. 쐐기형은 지반속에 관입하기 위한 용도이며 평면형은 실내실험시 사용되는 셀등에 설치하기 위한 것이다. 크기가 다른 6종류의 글라스비드와 3종류의 모래를 사용하여 압밀시험을 수행한 결과, 간극률이 감소함에 따라 전기비저항이 증가하였으며, Arichie 공식에 사용되는 m값이 입자의 크기보다 형상에 영향을 받는 것으로 나타났다. 액상화 수조에서 수행된 실험결과 체적간극률과 유사한 전기비저항 간극률이 산정되었다. 대형 토조에서 수행된 관입실험으로부터 간극률 주상도를 얻을수 있었다. 본 논문에서 제시된 4ERP는 포화 지반의 간극률을 효과적으로 산정할 수 있는 장비가 될 수 있을것으로 판단된다.

친환경 지반안정재를 약액주입재로 사용하여 보강한 노후 저수지의 보강효과 분석 (Analysis of the Reinforcement Effect of Aging Reservoir Reinforced by Environmental Soil Stabilizer as Chemical Grouting Material)

  • 김세민;서세관;조대성
    • 한국지반신소재학회논문집
    • /
    • 제20권2호
    • /
    • pp.1-11
    • /
    • 2021
  • 본 연구에서는 산업부산물인 고로슬래그와 순환유동층 보일러의 연소재를 주재료로 사용하여 시멘트와 유사한 경화반응을 유도하도록 개발된 친환경 지반안정재를 약액주입재로 사용하기 위한 실내시험과 시험시공에 관련된 연구가 진행되었다. 이를 위해 실내시험에서는 규산소다 및 실리카졸을 A액, 친환경 지반안정재(또는 OPC)를 B액으로 사용하여 시편을 제작하고, 실내시험을 실시하여 공학적·환경적 성능을 분석하였다. 그리고 실제 노후저수지에 시험시공을 실시하고, 현장에서의 투수시험, 전기비저항탐사를 실시하여 적용성을 분석하였다. 실내시험 결과, 친환경 지반안정재를 B액으로 사용한 약액주입재의 호모겔 압축강도는 보통 포틀랜드 시멘트와 비교하여 약 2.88~3.23배 큰 값을 나타내었다. 또한 대부분의 중금속 용출량이 보통 포틀랜드 시멘트와 비교하여 적고, 어독성 시험에서의 생존율도 100%로 나타났다. 따라서 실내시험 결과를 토대로 판단할 때 OPC에 비해 강도적, 환경적으로도 우수한 것으로 분석되었다. 노후 저수지에서의 시험시공 결과에서는 친환경 지반안정재를 약액주입재의 B액으로 사용하여 보강한 경우, 저수지 내부에서의 투수계수는 1/50 수준까지 감소하였다. 그리고 전기비저항 탐사결과 노후 저수지 내부의 전기비저항은 시간이 경과함에 따라 증가하여 포화대는 사라졌으며, 전반적으로 보강되는 것으로 분석되었다.

울주에서 발생한 땅밀림 특성 (Analysis of Land Creep in Ulju, South Korea)

  • 박재현;이상현;강한별;김현;정은석
    • 한국산림과학회지
    • /
    • 제113권1호
    • /
    • pp.14-30
    • /
    • 2024
  • 본 연구는 한국의 울주군에서 발생한 땅밀림지의 지질, 지형, 유효 토심, 토양경도, 전기비저항탐사, 지반조사를 통해 땅밀림 위험지 특성을 파악하여 땅밀림에 의한 인적, 물적 피해를 완화하기 위한 기초자료를 제공하기 위해 실시하였다. 이 지역은 2022년 도로 확장공사의 영향으로 땅밀림이 발생하였는데, 하층식생이 크게 발달하지 않은 경사지로 상단부는 강우 시 집수가 잘 되는 요형 지형으로 나타났다. 땅밀림지의 주 구성 암석은 셰일, 사암, 역암으로 구성되어 있으며 땅밀림지의 토양은 대조구의 토양보다 점토함량이 약 3.6배 많은 것으로 분석되었으며, 모래와 점토가 많고, 실트가 적은 결과로 전형적인 땅밀림 토양으로 나타났으며, 전기비저항 탐사결과 저비저항이상대가 나타나 지하수대가 형성되는 것으로 나타났다. 토양 경도는 대조구보다 땅밀림지가 낮았으며, 땅밀림지의 평균토심은 30.4 cm로 대조구 24.7 cm보다 깊은 붕적토 지역이었다. 이러한 땅밀림의 특징을 파악하여 효과적인 선제적 대응 체계와 모니터링 시스템 구축이 필요하다.

Simulations of Frequency-dependent Impedance of Ground Rods Considering Multi-layered Soil Structures

  • Lee, Bok-Hee;Joe, Jeong-Hyeon;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.531-537
    • /
    • 2009
  • Lightning has a broad frequency spectrum from DC to a few MHz. Consequently, the high frequency performance of grounding systems for protection against lightning should be evaluated, with the distributed parameter circuit model in a uniform soil being used to simulate grounding impedances. This paper proposes a simulation method which applies the distributed parameter circuit model for the frequency-dependent impedance of vertically driven ground rods by considering multi-layered soil structures where ground rods are buried. The Matlab program was used to calculate the frequency-dependent ground impedances for two ground rods of different lengths. As a result, an increase of the length of ground rod is not always followed by a decrease of grounding impedance, at least at a high frequency. The results obtained using the newly proposed simulation method considering multi-layered soil structures are in good agreement with the measured results.

500[kV] 송전철탑 접지설계를 위한 다층토양구조의 균일매질 등가화에 관한 연구 (A Study on the Identification of Equivalent Uniform Soil Model for Grounding Design of 500[tV] Transmission Towers)

  • 최종기;이성두;이동일;정길조;김경철
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.22-28
    • /
    • 2005
  • 접지설계에 있어서 토양의 전기적 특성은 접지극의 형상과 더불어 가장 중요한 설계요소 중 하나이며 이러한 토양의 전기적 특성은 접지극이 매설될 지역의 고유한 저항률, 즉 고유저항률(specific earth resistivity)로 대표되어 왔다. 이처럼 고유저항률에 근거한 수작업 접지설계는 복잡한 구조와 특성을 갖는 실제 토양을 균일한 매질로 등가 화하는 절차를 필요로 한다. 본 논문에서는 미얀마 500[kV] 송전철탑 수작업 접지설계를 위하여 수평다층토양을 균일 매질로 등가화 하는 절차를 제시하였다.

모래의 수분함유량에 따른 비저항 및 비유전율의 주파수 의존성 (Frequency Dependent Resistivity and Relative Dielectric Constant with the Water Contents in Sand)

  • 이복희;차응석;최종혁;최영철;유양우;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2009
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than its ground resistance. Recently, some researches on the evaluation and modeling of the grounding impedances have been carried out but the results have not been yet sufficient. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of sand associated with water contents. As a result, the resistivity of sand is getting lower with increasing water content and it is nearly independent on the frequency in the range of less than 1MHz, and is decreased over the frequency range of above 1MHz. Also, the relative dielectric constant is rapidly decreased with the frequency in the range of less than 10kHz, but it is nearly not dependent on the frequency over the frequency range of 10kHz. It was found from this work that the frequency dependance of resistivity and relative dielectric constant of soil should be considered in designing the grounding systems for protection against lightning or surges.

  • PDF

사석 성토 지역의 비파괴 조사 기법 적용성 연구 (Study of Application for Using Nondestructive Method in Gravel Area)

  • 윤형구
    • 한국지반공학회논문집
    • /
    • 제39권7호
    • /
    • pp.49-56
    • /
    • 2023
  • 사석은 원지반의 지지력을 확보하고 구조물을 안정하게 지지할 수 있도록 다양한 목적으로 활용되고 있지만 사석이 적용된 지반의 특성을 관찰하기는 많은 어려움이 있다. 해당 연구에서는 전기비저항 탐사, 탄성파 탐사 그리고 지표 투과 레이더를 활용하여 사석이 포함된 지반의 해상도를 비교하고자 하였다. 사석으로 성토를 수행한 건설 현장에서 해당 비파괴 탐사 기법을 적용하였으며, 얕은 심도를 목적으로 실험하여 심도 2m까지 결과를 도시하였다. 전기비저항 탐사와 탄성파 탐사는 유사한 거동을 보여주었지만, 지표 투과 레이더는 상대적으로 사석이 포함된 지반의 특성을 관찰하기에 한계를 보였다. 해당 기법을 검증하기 위하여 동적 콘 관입 시험을 수행하였으며, 전기비저항 및 탄성파 탐사 결과와 국부적인 영역에서 유사한 거동을 보였다.

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.

에코콘 탐사시스템을 이용한 지반특성 및 지반환경 조사

  • 정하익;김영진;홍승서;강동우;이경국
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.67-70
    • /
    • 2004
  • The purpose of this study is to develop the investigation technology of ground characteristics and environments using eco cone penetration system. The underground environments of landfill was investigated and analyzed by this eco cone system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in eco cone penetration system. This eco cone penetration system provides a continuous profile of measurements in underground, and provides repeatable, reliable and cost effective results for investigation of clean and contaminated ground.

  • PDF