• 제목/요약/키워드: Soil box boundary

검색결과 14건 처리시간 0.022초

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

A new way to design and construct a laminar box for studying structure-foundation-soil interaction

  • Qin, X.;Cheung, W.M.;Chouw, N.
    • Earthquakes and Structures
    • /
    • 제17권5호
    • /
    • pp.521-532
    • /
    • 2019
  • This paper describes the construction of a laminar box for simulating the earthquake response of soil and structures. The confinement of soil in the transverse direction does not rely on the laminar frame but is instead achieved by two acrylic glass walls. These walls allow the behaviour of soil during an earthquake to be directly observed in future study. The laminar box was used to study the response of soil with structure-footing-soil interaction (SFSI). A single degree-of-freedom (SDOF) structure and a rigid structure, both free standing on the soil, were utilised. The total mass and footing size of the SDOF and rigid structures were the same. The results show that SFSI considering the SDOF structure can affect the soil surface movements and acceleration of the soil at different depths. The acceleration developed at the footing of the SDOF structure is also different from the surface acceleration of free-field soil.

수평으로 경사진 박스암거 위 콘크리트 포장 슬래브의 최적 줄눈위치 (Optimal Joint Position in Concrete Pavement Slab over Skewed Box Culvert)

  • 염우성;정호성;연우;손덕수;이재훈;정진훈
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.47-55
    • /
    • 2013
  • PURPOSES : The purpose of this study is to investigate the optimal joint positions which can minimize distresses of concrete pavement containing box culvert with horizontally skewed angles. METHODS : The concrete pavement containing the box culvert with different skewed angles and soil cover depths was modeled by 3 dimensional finite element method. The contact boundary condition was used between concrete and soil structures in addition to the nonlinear material property of soil in the finite element model. A dynamic analysis was performed by applying the self weight of pavement, negative temperature gradient of slab, and moving vehicle load simultaneously. RESULTS : In case of zero skewed angle ($0^{\circ}$), the maximum tensile stress of slab was the lowest when the joint was positioned directly over side of box culvert. In case there was a skewed angle, the maximum tensile stress of slab was the lowest when the joint passed the intersection between side of the box culvert and longitudinal centerline of slab. The magnitude of the maximum tensile stress converged to a constant value regardless the joint position from 3m of soil cover depth at all of the horizontally skewed angles. CONCLUSIONS : More reasonable and accurate design of the concrete pavement containing the box culvert can be possible based on the research results.

1g 진동대시험에서 사면의 위치에 따른 경계조건 영향평가 (Effects of Slope Location on the Boundary Condition in the 1g Shaking Table Test)

  • 정수근;김용;김대현
    • 지질공학
    • /
    • 제32권4호
    • /
    • pp.535-545
    • /
    • 2022
  • 내진설계에서 지반의 안정성을 향상시키기 위해서는 지진하중을 받는 지반의 동적거동을 이해하는 것이 필수적이다. 따라서 지반의 동적거동을 이해하는데 진동대 시험은 중요한 실험 중 하나이다. 이러한 진동대 시험에서 가장 중요한 인자 중 하나인 경계조건에 대한 영향성을 확인하고자 하였다. 본 연구의 목적은 지진하중에 의한 모형사면의 위치별 경계조건의 영향성을 확인하고자 한다. 연성토조(laminar shear box, LSB)안에 모형사면을 제작하여 위치에 따라 경계조건의 영향을 확인하였다. 토조 벽면으로부터 100, 50, 25 cm 지점에 각각의 모형사면을 조성하여 동일한 크기의 정현파 지진하중을 입력하였다. 그 결과, 모형사면에 대한 진동대 실험 시 25 cm 지점에 위치한 경우는 경계조건의 영향을 크게 받아 가속도가 증폭하는 모습을 확인할 수 있었으며 50~100 cm 지점에 위치한 경우 경계조건의 영향이 감소하여 적합한 위치로 판단되었다.

측면 경계 조건이 다른 토조들의 동적거동 비교에 관한 연구 (A Comparative Study on Dynamic Behavior of Soil Containers that Have Different Side Boundary Conditions)

  • 김진만;류정호;손수원;나호영;손정웅
    • 한국지반공학회논문집
    • /
    • 제27권12호
    • /
    • pp.107-116
    • /
    • 2011
  • 1g 진동대 실험을 수행할 때, 양 벽면이 고정되어 있는 강성토조를 시용하기도 한다. 1g 진동대 실험에 강성토조를 사용하는 경우 양 쪽 벽면에서 파동이 반사가 되고 모형지반의 동적 전단 변형이 구속되어 위상차 및 가속도 증폭이 제대로 발생하지 않는 문제가 생긴다. 반면 토조를 얇은 층(Laminate)으로 구성하고 각 층 사이의 수평거동을 허용해 주는 특수형태의 토조(층 분할 토조, Laminar Shear Box)를 사용하면 이와 같은 문제를 상당부분 해결할 수 있다. 본 연구에서는 1g 진동대 실험을 통하여 경계 조건이 서로 다른 두 종류의 토조(강성토조; Rigid Box or Rigid container, 층 분할 토조; Laminar Shear Box or Laminar container)에 동적 특성이 동일한 연약한 모형 점토 지반을 조성하여 그 거동의 차이들을 정량적으로 분석하였다. 그 결과, 강성토조는 벽면의 강성으로 인해 지반내의 위상차가 적게 발생하였으며, 가속도 증폭 양상은 자유장 거동과 많이 다른 결과를 보였다. 이와 달리 층 분할 토조는 지반의 전단변위를 구속하지 않고 실제지반에서 발생하는 지반 내 위상차 및 가속도 증폭 현상을 상대적으로 잘 재현하는 것으로 나타났다. 결론적으로, 층 분할 토조(Laminar shear box)는 강성토조(Rigid Box)와 비교할 때 자유장 지반의 동적거동을 더 정확히 재현해 주는 것을 실험결과를 통해 분석할 수 있었다.

내진 연구를 위한 전단상자 제작기술 개발 (Development of Laminar Box Manufacturing Technique for Earthquake Engineering)

  • 이용재
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.100-107
    • /
    • 2001
  • One major problem in the model testing is the boundary effect and size effect caused by the limit in the size of the container. To overcome this problem, various types of laminar boxes are gradually manufactured and used in the shaking table test, which ideally has zero stiffness to horizontal shear. In this study, a small-scale laminar box is manufactured, which is composed of 6 thin aluminum rectangular hollow plates, and its inside dimensions are 300 mm length by 200 mm width by 350 mm depth. Shaking table tests are performed both with the laminar box and the rigid box under the same conditions, where displacements and accelerations are measured at various points of the box and model ground. As result of analyzing the measured data, during the propagation of input seismic motion from the bottom to the ground surface, the relative displacement of the model ground and the amplification of acceleration is hardly amplified in the rigid box. Because of the effect of stress waves reflecting from the rigid wall, the acceleration is slightly decreased at the edge in the rigid box. The laminar box, manufactured in this study, has a problem in that the soil behavior at the edge of ground surface is affected by the inertia force of the top layer due to its excessive self-weight.

  • PDF

연성토조의 경계조건 변화에 따른 가속도 증폭 분석 (Acceleration Amplification Analysis according to Changes in Laminar Shear Box Boundary Conditions)

  • 정수근;김용;박경호;김대현
    • 지질공학
    • /
    • 제32권1호
    • /
    • pp.143-155
    • /
    • 2022
  • 본 연구에서는 지진 모사실험을 진행하는 1 g 진동대 실험에 올라가는 연성토조(Laminar Shear Box, LSB)라고 하는 토조의 경계조건(Boundary effect)을 달리하여 다른 조건에 따른 응답가속도 증폭에 대한 분석하였다. LSB의 양 옆을 고정하여 경계조건을 달리하여 실험을 진행하였고, 가속도계를 각 동일한 위치에 설치하여 2가지 시료에 대하여 실험을 진행하였다. 또한, DEEPSOIL v7 프로그램을 이용하여 1차원 지반응답해석을 통하여 자유장 조건에서와 비교 분석하였다. 그 결과 가속도가 하층부에서 상층부로 올라갈수록 증폭하는 모습을 확인할 수 있었고, 지반응답해석과 비교한 결과, 자유장 조건에서 해석과 비슷하게 나오는 것을 확인할 수 있었다. SA분석결과, 지반응답해석과 유사한 결과를 얻을 수 있었으며, 고정한 경우는 PSA가 더욱 증폭하는 결과를 확인할 수 있었다.

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제29권2호
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동 (Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test)

  • 홍영호;변용훈;채종길;이종섭
    • 한국지반공학회논문집
    • /
    • 제31권3호
    • /
    • pp.51-62
    • /
    • 2015
  • 직접전단시험은 전단상자의 경계조건에 따라 흙의 전단거동이 달라지는 것으로 알려져있다. 본 연구의 목적은 Type-A 형태의 기존 직접전단시험기의 문제점에 대해 분석하고 Type-C 형태의 직접전단시험기의 개발을 통해 신뢰성 높은 직접전단결과를 도출하는데 있다. 기존 직전단시험기와 새로 개발된 직접전단시험기를 사용하여 상대밀도가 60%로 조성된 모래시료에 대해 초기 구속응력 50kPa, 100kPa, 200kPa, 300kPa, 400kPa에서 0.5mm/min의 일정한 전단속도로 직접전단시험을 수행하였다. 일정수직하중 조건에서 수행된 Type-A의 직접전단시험기와 Type-C 시험기의 결과를 비교하여 새로 개발된 시험기의 신뢰성을 평가하였다. 또한 새로 개발된 시험기를 사용하여 일정 수직하중 조건과 정압조건의 두 가지 구속조건에 대한 직접전단시험을 수행하여 그 결과를 비교, 분석하였다. 실험결과, Type-A의 직접전단시험기에서는 하중재하판과 상부 전단상자가 기울거나, 흙의 체적변화로부터 발생되는 시료와 전단상자 내부 벽면간의 마찰이 전단면에 작용하는 응력에 영향을 끼치게 되는 문제가 발생하였다. Type-A의 직접전단시험기에서는 전단상자 형태와 경계조건에 따라 전단강도가 과대 혹은 과소평가 되었다. Type-C의 직접전단시험기에서는 구속조건에 상관없이 일관성있는 실험결과를 나타내었다. 본 연구는 Type-C의 형태로 개발된 직접전단시험기를 통해 Type-A 직접전단시험법의 문제점을 해결하고 신뢰성있는 결과를 도출할 수 있음을 보여준다.

강우로 인한 조립토 사면에서의 토층 두께 변화에 따른 사면의 활동 분석: 실내 모형실험 (Analysis on the Rainfall Triggered Slope Failure with a Variation of Soil Layer Thickness: Flume Tests)

  • 사공명;유재호;이성진
    • 한국지반공학회논문집
    • /
    • 제25권4호
    • /
    • pp.91-103
    • /
    • 2009
  • 강우로 인하여 사면을 구성하는 흙의 상태는 복잡한 과정을 거치며, 이와 동반된 사면의 활동은 흙의 역학적 거동의 변화뿐만 아니라, 강우와 관계된 기상특성, 지층구조의 특성, 지형적 특성 등 다양한 요소에 의존적이다. 본 논문에서는 여러 요소 중 사면의 토층 두께의 변화에 따른 사면활동 양상 및 그와 수반되어 토체내에서 변화하는 흡입력과 체적함수비의 변화양상을 확인할 수 있다. 사면의 토층이 어느 정도 두꺼운 경우 침투선단의 하향이동이 관측되었으며, 침투선단이 도달한 위치에서는 일정한 크기의 흡입력이 감소하여 부의 간극수압이 영에 가까운 값을 보이는 것이 관측되었다. 침투선단이 불투수층인 토조 바닥에 도달한 이후 침투선단의 상향이동이 관측되었으며 이러한 관측결과는 다양한 크기의 공극의 존재에 의한 것으로 판단된다. 크기가 큰 공극이 존재하는 경우 모세관현상으로 인한 공극의 채움 효과는 다소 줄어들 수 있으며 하항 침투 시 덜 채워진 공극은 침투선단이 바닥면에 도달한 이후 다시 상향으로 이동할 경우 채워지는 것으로 판단된다. 이러한 가정은 체적함수비의 변화과정에서 확인되었다. 또한 조립토를 대상으로 하는 본 실험에서 토체의 두께가 두꺼운 경우(20cm) 사면의 활동은 침식에 의한 것으로 관측되었는데, 침식의 개시는 상부 표층의 흙이 완전히 포화된 경우 시작하는 것으로 확인되었다. 이에 비해 토층의 두께가 얇은 경우(10cm) 침식활동 보다는 사면전체가 덩어리로 활동하는 양상이 관측되었는데, 사면의 활동시점은 침투선단이 사면의 바닥에 도달한 시점으로 확인되었다. 이 경우 침투선단이 사면의 바닥면에 도달하면서 사면의 바닥면과 토조면 상에서의 마찰저항의 감수 침투로 인한 토체의 중량 증가 등의 요인이 상호 복합적으로 사면활동에 작용하는 것으로 판단된다.