• Title/Summary/Keyword: Soil Flushing System

Search Result 20, Processing Time 0.022 seconds

Evaluation of Remediation of Contaminated Soil Using PVDs (연직배수재를 이용한 오염도턍복원 특성 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun;Roh, Jeong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1400-1407
    • /
    • 2005
  • There are a number of approaches to in situ remediation that are used at contaminated sites for removing contaminants from the contaminated zone without excavating the soil. These include soil flushing, dual phase extraction, and soil vapor extraction. Of these techniques, soil flushing is the focus of the investigation in this paper. The concept of using prefabricated vertical drains(PVDs) for remediation of contaminated sites with fine-grained soils is examined. The PVD system is used to shorten the drainage path or the groundwater flow and promote subsurface liquid movement expediting the soil flushing process. The use of PVDs in the current state of practice has been limited to soil improvement. The use of PVDs under vacuum conditions is investigated using sample soil consisting of silty sand.

  • PDF

The Characteristics of Soil Remediation by Soil Flushing System Using PVDs (연직배수재를 이용한 토양세정시스템의 오염토양정화 특성)

  • Park, Jeong-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.5
    • /
    • pp.76-86
    • /
    • 2007
  • For the purpose of ground improvement by means of soil flushing systems. Incorporated technique with prefabricated vertical drains have been used for dewatering from fine-grained soils. The laboratory model tests were performed by using the flushing tracer solutions for silty soils and recorded the tracer concentration changes with the elapsed time and flow rates. A mathematical model for prediction of contaminant transport using the PVD technology has been developed. The clean-up times for the predictions on both soil condition indicate more of a sensitivity to the dispersivity parameter than to the extracted flow rate and vertical velocity parameters. Based on the results of the analyses, numerical analysis indicate that the most important factor to the in-situ soil remediation in prefabricated vertical drain system is the effective diameter of contaminated soil.

Ultrasonic flushing 기법에 의한 유류오염토양의 복원에 관한 실험연구

  • Jeong, Ha-Ik;Oh, In-Gyu;Kim, Sang-Geun;Lee, Yong-Su;Yoo, Jun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.13-17
    • /
    • 2002
  • Ultrasonic waves have several mechanical, chemical, and biological effects on a saturated soil medium. Their mechanical effects, popularly known as cavitation. Cavitation is the rapid and repeated formation, and resulting implosion, of imcrobubbles in a liquid, resulting in the propagation of microscopic shock waves. In a soil-liquid system, their mechanical effects generate high differntial fluid-particle velocities and microscopic shock waves. The velocity perturbations are capable of dislodging oil in the system by overcoming the forces binding oil to sand particles. In this study, a series of laboratory experiments involving the simple flushing and ultrasonic flushing were carried out. An increase in permeability and oil removal rate were observed in ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of ultrasonics.

  • PDF

Remediation of Copper-Contaminated Soil using Low Molecular Weight Organic Acid Flushing Technique (저분자량 유기산 세척을 이용한 오염토양으로부터의 Cu제거에 관한 연구)

  • 이기철;강순기;공성호
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.1
    • /
    • pp.30-36
    • /
    • 1998
  • For successful soil flushing process selection of appropriate flushing reagents is essential. Futhermore, obtaining operating parameters for site remediation application through various bench-scale tests is also important. In this research a series of organic acids (acetic, citric, oxalic, and succinic acids) were tested for flushing capability. Copper-contaminated natural soil was used as a test medium, and flushing experiments were performed with batch system. All the organic acids used did not provide effective flushing conditions at concentration of 1 mM. At the acid concentration of 50 and 100 mM copper was removed efficiently although 50 and 100 mM did not show any significant differences in removal efficiencies. Citric acid and oxalic acid removed copper more efficiently than the others, and especially, citric acid showed over 87% of removal efficiency of copper at near neutral pH of 5 to 7. Speciation of extracted copper using GEOCHEM simulation showed majority of extracted copper existed as complexed with organic acids and only small portion of organic acids were complexed with copper indicating promising application of soil flushing with organic acid to heavy metal-contaminated site remediation.

  • PDF

Electrokinetic Characteristic of Natural Soil with Flushing Agents (세척제에 따른 자연토의 동전기 특성)

  • 김익현;이정철;김병일;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.635-640
    • /
    • 2003
  • Electrokinetic characteristic of natural soil dependent on flushing agents is studied to determine the best agent used in the hybrid electrokinetic remediation system. The soil containing 7.6% Fe$_2$O$_3$is spiked with lead. The flushing agents to be inject into anode are HCl, Acetic acid, Citric acid, EDTA and SDS. Test results showed that the early electrical potential of EDTA is lower than the value of the others. And the pH in anode reservoir is higher. Elcetrokinetic characteristic of all the sample except for EDTA is about the same.

  • PDF

A Pilot Study for Remediation of Groundwater by Surfactant -Enhanced Soil Flushing

  • Park, Jong Oh;Lee, Dal-Heui
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.5
    • /
    • pp.1-7
    • /
    • 2016
  • The removal of non-aqueous phase liquids (NAPLs) from groundwater using pure water, via pump and treat, is quite ineffective due to their low solubility and hydrophobicity. Therefore, the objectives of pilot tests were to select potentially suitable surfactants that solubilize tetrachloroethylene (PCE) and trichloroethylene (TCE) present as contaminants and to evaluate the optimal range of process parameters that can increase the removal efficiency in surfactant-enhanced soil flushing (SESF). Used experimental method for surfactant selection was batch experiments. The surfactant solution parameters for SESF pilot tests were surfactant solution concentration, surfactant solution pH, and the flow rate of surfactant solution in the SESF pilot system. Based on the batch experiments for surfactant selection, DOSL (an anionic surfactant) was selected as a suitable surfactant that solubilizes PCE and TCE present as contaminants. The highest recovery (95%) of the contaminants was obtained using a DOSL surfactant in the batch experiments. The pilot test results revealed that the optimum conditions were achieved with a surfactant solution concentration of 4% (v/v), a surfactant solution pH of 7.5, and a flow rate of 30 L/min of surfactant solution (Lee and Woo, 2015). The maximum removal of contaminants (89%) was obtained when optimum conditions were simultaneously met in pilot-scale SESF operations. These results confirm the viability of SESF for treating PCE and TCE-contaminated groundwater.

Semi-pilot Study of Electrokinetic Process for Phenanthrene Removal from Kaolinite

  • Lee, You-Jin;Park, Ji-Yeon;Kim, Sang-Joon;Lee, Young-Cheol;Yang, Ji-Won
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.215-218
    • /
    • 2004
  • The electrokinetically enhanced soil flushing had a great potential to improve the removal efficiency of polycyclic aromatic hydrocarbons (PAHs) from low permeable soils. A semi-pilot study of surfactant-enhanced electrokinetic process was investigated for the removal of phenanthrene from kaolinite. A nonionic surfactant, Tergitol 15-S-12 at 10 g/L was introduced as a flushing agent and 0.001M of sodium chloride was used as an electrolyte. When the constant voltage of 100 V was applied to the system for 25 days, only 0.66 kWh of electric power was consumed and the amount of electroosmotic flow was 6.9 L. The removal efficiency of phenanthrene was about 40 % and it can be improved by increasing the ion concentration of the flushing solution or the applied voltage.

  • PDF

Study of Surfactant Enhanced Remediation Methods for Organic Pollutant(NAPL) Distributed over the Heterogeneous Medium (계면활성제를 이용한 불균질 매질에서 유기오염물(NAPL)의 정화효율에 관한 실험)

  • 서형기;이민희;정상용
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.51-59
    • /
    • 2001
  • Column and box tests were performed to investigate the removal efficiency of NAPL using the surfactant enhanced flushing In heterogeneous medium. Homogeneous Ottawa sand and heterogeneous soil were used to verify the increase of remediation efficiency for the surfactant enhanced flushing in column test. Box tests with two different heterogeneous sub-structure were performed to quantify the capability of the surfactant enhanced flushing as a remediation method to remove NAPL from the heterogeneous medium. Two different grain size sand layers were repeated in the box to simulate the heterogeneous layer formation and the modified fault structure was built to simulate the fault system in the box. O-xylene as a LNAPL and PCE as a DNAPL were used and oleamide as a non-ionic surfactant. The maximum NAPL effluent concentration with 1% oleamide flushing in the homogeneous column test increased about 460 times compared to that with only water flushing and about 250 times increased in the real soil column test. In heterogeneous medium, the maximum effluent concentration increased about 150 times in 1% oleamide flushing and most of NAPL were removed from the box within 8 pore volume flushing, suggesting that the removal efficiency increased very much compared to in only water flushing. Results investigated the capability of the surfactant enhanced remediation method to remove NAPL even in heterogeneous medium.

  • PDF

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF