• Title/Summary/Keyword: Softening temperature

Search Result 405, Processing Time 0.027 seconds

The Prediction of Dynamic Recrystallization and Grain Size of 304 Stainless Steel during Hot Deformation (스테인레스 304의 열간동적재결정과 미세조직 예측)

  • Kwon Y. P.;Cho J. R.;Lee S. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • The flow stress of 304 stainless steel during high during hot forming process were determined by conducting hot compression tests at the range of 1273 K-1423 K and 0.05 /s-2.0 /s as these are typical temperature and strain rate in hot forging operation. Based on the observed phenomena, a constitutive model of flow stress was assumed as a function of strain, strain rate, temperature. Dynamic recrystallization was found to be the major softening mechanism with this conditions as previous studies. A finite element analysis was performed to predict the recrystallized volume fraction and the mean grain size in hot compression of 304 stainless steel.

  • PDF

The Prediction of Dynamic Recrystallization and Grain Size of 304 Stainless Steel during Hot Deformation (304 스테인리스강의 열간동적재결정과 미세조직 예측)

  • 권영표;조종래;이성열;이정환
    • Transactions of Materials Processing
    • /
    • v.10 no.7
    • /
    • pp.573-578
    • /
    • 2001
  • The flow stress of 304 stainless steel during hot forming process were determined by conducting hot compression tests at the range of 1273 K∼1423 K and 0.05 /s∼2.0 /s as these are typical temperature and strain rate in hot forging operation. In this material, Dynamic recrystallization was found to be the major softening mechanism with this conditions as Previous studies. Based on the observed phenomena, a constitutive model of flow stress was assumed as a function of strain, strain rate, temperature. In the constitutive model, the effects of strain hardening and dynamic recrystallization were taken into consideration. A finite element method connected to constitutive model was performed to predict the dynamic recrystallization behaviors and also stress-strain curves in hot compression of 304 stainless steel.

  • PDF

Optical properties of the glass fiber by adding Ga$_2$O$_3$ in the SiO$_2$-PbO-K$_2$O-Al$_2$O$_3$ system for Infrared sensor (Ga$_2$O$_3$ 첨가에 따른 SiO$_2$-PbO-K$_2$O-Al$_2$O$_3$계 적외선 센서용 Glass fiber의 광학적 특성)

  • 윤상하;강월호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.68-71
    • /
    • 1996
  • In the study, the thermal and optical properties of SiO$_2$-PbO-K$_2$O-Al$_2$O$_3$ g1asses were investigated. According to Ga$_2$O$_3$ addictions, the properties of bulk glass, transition temperature and softening temperature were increased, whereas thermal expansion coefficient was decreased; In the optical properties, refractive index was increased, and IR cut-off wavelength was enlarged from 4.64$\mu\textrm{m}$ to 5.22$\mu\textrm{m}$. But, the optical loss of fiber was decreased.

  • PDF

A Study on the Treeing Phenomenon due to the Post-Cure Conditions of the Thermo-Setting Epoxy Resin (열경화성 EPOXY수능의 2인경화촉진에 따른 Treeing 현상에 관한 연구)

  • 조정수;김종경;백선환;이종호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.6
    • /
    • pp.406-413
    • /
    • 1988
  • This paper is to investigate relationships between tree inception voltage, tree extension or treeing breakdown voltage and physical characteristics changing as parameter of the post-cured conditions of thermo-setting epoxy resin. According to the results in this paper, the optimal tree inception voltage and treeing breakdown voltage of the samples are obtained for the sample post cured for 15 hours at 100 'C. It can be noticed that these results are closely related with the state of interior molecule coupling and three-dimen sional cross-linked of thermo-setting epoxy resin. And tree inception, tree extension and treeing breakdown of the samples are affected significantly on the post-cured conditions and the cooling method after post-cured of thermo-setting epoxy resin. Moreover, the tree extension by ambient temperature are closely related with softening temperature of thermo-setting epoxy resin.

  • PDF

The Effects of Molybdenum Content on the Dynamic Properties of Tungsten-based Heavy Alloys

  • Lee, Woei-Shyan;Chan, Tien-Yin
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1155-1156
    • /
    • 2006
  • Hopkinson bar dynamic test under strain rates ranging from 2000 $s^{-1}$ to 8000 $s^{-1}$ at room temperature revealed that the flow stress of tungsten heavy alloys depended strongly on the strain, strain rate, and the content of molybdenum. The variation of flow stress was caused by the competition between work hardening and heat softening in the materials at different strain rates. The high temperature strength of the matrix phase was increased by the addition of molybdenum, which enhanced the strength of the tungsten heavy alloys in high strain rate test.

  • PDF

Effect of Frit and Sintering Conditions on the Microstructure and Electrical Property in Ag and Ag/Pd Thick Film Conductors (프릿트 및 소결조건이 Ag 및 Ag/Pd계 후막도체의 미세구조와 전기적성질에 미치는 영향)

  • 구본급;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.6
    • /
    • pp.623-630
    • /
    • 1988
  • As a function of the composition and content of frit, the electrical property of Ag and Ag/Pd thick film conductors were investigated with microstructure. With increasing sintering temperature in Ag-frit thick film conductors, electrical sheet resistivity decreased, but again increased above 80$0^{\circ}C$. And when frit contents is 5wt%, compact and homogenious microstructure can be obtained, then electrical sheet resistivity has minimum value. In Ag/Pd-frit film conductor, the electrical sheet resistivity decreased with increasing sintering temperature. The system which having frit with low softing point has lower sheet resistivity then to add high softening point frit.

  • PDF

A comparative study on thermal, mechanical and dielectric characteristics of low density polyethylene crosslinked by radiation and chemical methodes (화학적방법과 방사선으로 가교된 저밀도 폴리에티렌의 열적 기계적 및 유전적 특성의 비교연구)

  • 김봉흡;강도열;김정수
    • 전기의세계
    • /
    • v.25 no.2
    • /
    • pp.100-106
    • /
    • 1976
  • A comparative study on thermal, static mechanical and dielectric characteristics were made over a temperature range of ca.20.deg.C to 320.deg.C and a frequency range of KHZ to MHZ band on low density polyethylene specimens crosslinked, respectively, by radiation and chemical method. The thermal property of both specimens shows that softening point appears to unchange by crosslinking, however, melting and liquidizing temperatures attain rapid increase at the imitiation of crosslinking. Mechanical properties show little difference to both specimens crosslinked by different method, further the behaviors were discussed in connection with the relaxation of molecular segments in amorphous phase. Dose dependent dielectric characteristics observed at ambient temperature under several fixed frequencies exhibit extremities at ca. 20 Mrad and the behaviors also were interpreted qualitatively by taking into consideration of dipole concentration change in amorphous phase together with the role of specimen geometry to the depth of oxidative layer. Observing frequency dependent dielectric characteristics, it was also proved that ionic conduction loss is appreciably greater in the specimen prepared by chemical method than that by radiation.

  • PDF

The Aging Behavior of Overhead Conductor due to Forest Fire (산불에 의한 가공송전선의 열화거동)

  • Kim, Byung-Geol;Kim, Shang-Shu;Han, Se-Won;Kim, Jin-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1105-1111
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about aging behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800\;^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90 %. The detailed results will be given in the text.

Expansion Characteristics of the Hydrated Sodium Silicate (수화된 규산소다의 팽창 특성)

  • Kong, Yang-Pyo;Cho, Ho-Yeon;Suhr, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • Hydrated sodium silicate with 25 wt% water contents was synthesized by hydrothermal reaction using anhydrous sodium silicate. The hydrated sodium silicate was expanded at $370^{\circ}C$ for 30 min. and then pulverized, classified (- 200 mesh) and press-formed. The samples were heat treated at $400{\sim}900^{\circ}C$ for 30 min. in order to study the expansion characteristics depending on heat treatment temperature. A porous body with closed pore was formed above $600^{\circ}C$. The volume expansion ratio and the pore size were increased and the specific gravity was decreased with increasing heat treatment temperature. However, the volume expansion ratio was decreased and the specific gravity was increased above $850^{\circ}C$ due to the softening of the sodium silicate.

The SAG Behavior of Overhead Conductor due to Forest Fire (산불에 의해 가열된 가공송전선의 이도거동)

  • Kim, Byung-Geol;Kim, Shang-Shu;Jun, Wan-Gi;Han, Se-Won;Kim, Jin-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF