• Title/Summary/Keyword: Soft-start technique

Search Result 8, Processing Time 0.019 seconds

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Design and Control of SRM For LSEV Drive

  • Lee, Hee-Chang;Lee, Man-Hyung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.96-101
    • /
    • 2004
  • This paper presents an application of SRM drive for LSEV(Low Speed Electric Vehicle). In this paper, a 5〔㎾〕 SRM for a traction of a LSEV is to design and investigate the characteristics of the drive system. The main design parameters and control strategy are given. In the control method, a current control, for the soft-starting technique at a starting operation, is adopted. In the high speed range, an angle control technique is implemented, for a high efficiency drive of SRM. Some experimental tests are executed to find the drive performances.

A Design of Battery Charger using Phase-Lock technique (Phase-Lock 기법을 이용한 Battery 충전기 설계)

  • Song, Eui-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.456-458
    • /
    • 1997
  • The phase-lock technique is applied to a three-phase semi-bridge type battery charger system. Using an inner fast dynamic loop, the phase-locked voltage control (PLVC) technique of three-phase semi-bridge converter is proposed to give a frequency synchronism and to reduce the subharmonics due to the unbalance of transformer or power line. To protect the power devices, the two stage soft-start, function with softly locking the phase and softly increasing the current is presented. As limiting the reference voltage of the inner voltage control loop, muti-lock phenomena are removed on the PLVC loop. A current limit function is also proposed to limit the current of battery and converter. The proposed controller is confirmed through experiment results.

  • PDF

Soft Load Balancing Using the Load Sharing Over Heterogeneous Wireless Networks (이기종 무선 환경에서 Load sharing을 이용한 Soft Load Balancing 기술)

  • Son, Hyuk-Min;Lee, Sang-Hoon;Kim, Soo-Chang;Shin, Yeon-Seung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7A
    • /
    • pp.757-767
    • /
    • 2008
  • Start Ongoing next generation networks are expected to be deployed over current existing networks, in the form of overlayed heterogeneous networks, in particular, in hot spot areas. Therefore, it will be necessary to develop an interworking technique such as load balancing, to achieve increased overall resource utilization in the various heterogeneous networks. In this paper, we present a new load balancing mechanism termed 'soft' load balancing where the IP(Internet Protocol) traffic of a user is divided into sub-traffic, each of which flows into a different access network. The terminology of soft load balancing involves the use of both load sharing and handover techniques. Through a numerical analysis, we obtain an optimal LBR (Load Balancing Ratio) for determining the volume of traffic delivered to each network over an overlayed multi-cell environment. Using the optimal LBR, a more reliable channel transmission can be achieved by reducing the outage probability efficiently for a given user traffic.

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.

Development of Dimming control system for 400W Metal Halide Lamp by Electronic Ballast and Power Line Modem (전력선모뎀 및 조광제어 안정기를 이용한 400W Metal Halide Lamp의 조광제어 시스템 개발)

  • Park, Chong-Yeon;Choi, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.193-198
    • /
    • 2009
  • In this paper, we developed remote dimming control system of electronic ballast for 400W metal halide lamp. This ballast could limit ignition current and soft start-up technique by the inverter with LCsCp resonance tank. The dimming circuit can dim from 400W to 200W by varying of the inverter switching frequency. The PLM consists of coupling circuit, BPF(Band-Pass Filter), FSK(Frequency Shift Keying) Modem and ${\mu}$-controller(Micro Controller). By coupling electronic ballast with PLM, the system that able to dimming the lamp through PLM is demonstrated by experimental results.

  • PDF

Donor Muscle Flap Harvest with Endoscopic Assistance (내시경을 이용한 공여 근피판의 채취)

  • Ahn, Hee-Chang;Park, Bong-Kweon
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.124-130
    • /
    • 2001
  • Both of latissimus dorsi and rectus abdominis muscles are workhorse for various reconstructive surgeries. These muscle flaps have been used widely for soft tissue coverage, tissue augmentation, and functional muscle transfer. However, the traditional method for muscle harvest requires a long incision that often results in an unsightly scar and becomes the main concern of the patient. The purpose of this study is to introduce our clinical experience of endoscopic harvest of latissimus dorsi muscle and rectus abdominis muscle, and to make comparison with traditional harvest of these two muscle flaps. Of the 13 rectus abdominis muscles free flaps, 6 muscles were harvested traditionally and 7 muscles were harvested with endoscopic assistance. Of the 21 latissimus dorsi muscle free flaps, 12 muscles were harvested traditionally and 9 muscles were harvested with endoscopic assistence. Follow up period was between 6 months and 24 months. The patients age ranged from 7 to 70 years old. The result revealed no statistically significant differences in the amount of intraoperative bleeding, incidence of postoperative hematoma and seroma, and the incidence of donor-site wound infection. However, patients feel less pain and start earlier and better movement after the operation with endoscopically assisted harvest. This technique is easy to learn, is safe, and can reduce substantially the donor site morbidity comparing traditional harvesting technique.

  • PDF