• Title/Summary/Keyword: Soft-Tip

Search Result 143, Processing Time 0.026 seconds

Blade Type Field Vs Probe for Evaluation of Soft Soils (연약지반 평가를 위한 블레이드 타입 현장 전단파 속도 프로브)

  • Yoon, Hyung-Koo;Lee, Chang-Ho;Eom, Yong-Hun;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.33-42
    • /
    • 2007
  • The assessment of shear wave velocity($V_s$) in soft soils is extremely difficult due to the soil disturbances during sampling and field access. After a ring type field $V_s$ probe(FVP) has been developed, it has been applied at the southern coastal area of the Korean peninsular. This study presents the upgraded FVP "blade type FVP", which minimizes soil disturbance during penetration. Design concerns of the blade type FVP include the tip shape, soil disturbance, transducers, protection of the cables, and the electromagnetic coupling between transducers and cables. The cross-talking between cables is removed by grouping and extra grounding of the cables. The shear wave velocity of the FVP is simply calculated by using the travel distance and the first arrival time. The large calibration chamber tests are carried out to investigate the disturbance effect due to the penetration of FVP blade and the validity of the shear waves measured by the FVP. The blade type FVP is tested in soils up to 30m in depth. The shear wave velocity is measured every 10cm. This study suggests that the upgraded blade type FVP may be an effective device for measuring the shear wave velocity with minimized soil disturbance in the field.

Evaluation of Taste in the Patients with Recurrent Aphthous Ulceration by Electrogustometer (전기미각측정기를 이용한 재발성 아프타성 궤양 환자의 미각평가)

  • Jun, Jin-Yong;Ahn, Yong-Woo;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study was to investigate whether there were any changes in taste sensitivity with recurrent aphthous ulceration. Nintyseven subjects(25 males and 72 females) were included for the study and they were categorized into 2 groups(recurrent aphthous ulceration 27 persons, control 70 persons), recurrent aphthous ulceration group was investigated in the department of Oral Medicine, College of Dentistry, Pusan National University from April, 2005 to August, 2006 and control group was investigated in the clinic at Incheon city from June, 2006 to August, 2006. The electrical taste thresholds were measured using an electrogustometer of the 4 different sites(tongue tip, tongue lateral, circumvallate papilla and soft palate) in oral cavity. The results were as follows ; 1. The electrical taste threshold showed significant lower in the RAU group. 2. The electrical taste threshold showed significant lower in female group, and showed significant lower except soft palate in male group of the RAU group. 3. The electrical taste threshold showed a tendency to increase in all site of the multiple RAU group, but there were no significant differences. 4. The electrical taste threshold showed a tendency to increase in tongue lateral of the acute RAU group, and showed a tendency to increase in tongue tip, circumvallate papilla, soft palate of the chronic RAU group. 5. After treatment, electrical taste threshold was significant increase than initial visit in the RAU group. 6. After treatment, NAS showed a tendency to decrease in the RAU group.

The effects of mandibular setback osteotomy on the oropharyngeal airway space in mandibular prognathic patients (하악전돌 환자에서 하악골 후퇴수술이 기도공간에 미치는 영향)

  • Kim, Hyo-Young;Choi, Hyun-Gue;Kim, Eun-Kyung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.733-741
    • /
    • 1997
  • As a result of surgical orthodontic treatment of mandibular prognathism, changes take place in the skeletal and soft orofacial components. Although some investigators had stated that permanent reduction of airway space was observed after mandibular setback surgery, it was not clear that this permanent reduction was sustained during long-term follow-up. The purpose of this study was to assess the changes in oropharyngeal airway space and soft tissue orofacial component following the mandibular setback surgery and during the follow-up period. The correlation between the changes of the oropharyngeal airway space and the changes of other soft tissue orofacial component was also assessed. The findings of this study were as follows ; 1. The oropharyngeal airway space area decreased following mandibular setback surgery for mandibular prognathism and continued to decrease during the follow-up period(p<0.05). 2. The pharyngeal depth at Xi point level and the 2nd cervical vertebra point level decreased after the surgery and remained during the follow-up period(p<0.05). The decrease of these pharyngeal depth was correlated with the decrease of oropharyngeal airway space area(p<0.01). 3. The decrease of pharyngeal depth at the 3rd and 4th cervical vertebra point level was not significant after the surgery and during the follow up period. 4. The hyoid bone moved downward after the surgery(p<0.05), but returned to its original position during the follow-up period. 5. The length & height of tongue and the Position of epiglottis base did not change significantly(p>0.05). 6. The soft palate was displaced posteriorly after the surgery and remained to its changed position during the follow-up period(p<0.05) due to posterior displacement of tongue. The changes of soft palate were significantly correlated with the decrease of oropharyngeal airway space area(p<0.01). 7. The narrowing of oropharyngeal airway space was due to the posterior displacement of tongue above the level of epiglottis tip. The posterior displacement of tongue following mandibular setback osteotomy remained during the follow-up period.

  • PDF

A Study of Esthetic Facial Profile Preference In Korean (한국인의 연조직측모 선호경향에 대한 연구)

  • Choi, Jun-Gyu;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.327-342
    • /
    • 2002
  • Soft tissue profile is a critical area of interest in the development of an orthodontic treatment and diagnosis. The purpose of this study was to determine the facial profile preference of diversified group and to investigate the relationship between most Preferred facial Profile and existing soft tissue reference lines. A survey instrument of constructed facial silhouettes was evaluated by 894 lay person. The silhouettes had varied nose, lips, chin and soft tissue subnasale point. Seven sets of facial type were computer-generated by an orthodontist to represent distinct facial types. The varied facial profiles were graded on the basis of most preferred to least preferred. Every facial profile were measured by soft tissue reference lines(Ricketts E-line, Burstone B-line) to observe the most preferred facial profile. The results as follows: 1. In reliability test, the childhood group showed lower value than other groups, which means that this group has no concern on facial profile preference. 2. It appears that sexual and age difference made no significant difference in selecting the profile 3. An agreement to least preferred facial profile was higher than an agreement to most preferred facial profile. 4. Coefficient of concordance (Kendall W) was higher in the twentieth group. It means that a profile preference of the twentieth is distinct. 5. A lip protrusion (to Ricketts E-line and Burstone B-line) of most preferred facial profile was similar to measurements of previous study that investigate skeletal and soft tissue of esthetic facial profile of young Korean. So these reference lines can be used valuably in clinics. 6. Profile of excessive lip protrusion or retrusion to E-line & B-line was least preferred. 7. Most preferred profile of all respondents group was straight profile. Profile that showing convex profile was not pre(erred and the least preferred profile was concave profile.

Resistance Factor and Target Reliability Index Calculation of Static Design Methods for Driven Steel Pipe Pile in Gwangyang (광양지역에 적합한 항타강관말뚝의 목표신뢰성지수 및 저항계수 산정)

  • Kim, Hyeon-Tae;Kim, Daehyeon;Lim, Jae-Choon;Park, Kyung-Ho;Lee, Ik-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8128-8139
    • /
    • 2015
  • Recently, the necessity of developing the load and resistance factor design(LRFD) for soft ground improvement method has been raised, since the limit state design is requested as international technical standard for the foundation of structures. In this study, to develop LRFD codes for foundation structures in Korea, target reliability index and resistance factor for static bearing capacity of driven steel pipe piles were calibrated in the framework of reliability theory. The 16 data(in Gwangyang) and the 57 data(Korea Institute of Construction Technology, 2008) sets of static load test and soil property tests conducted in the whole domestic area were collected along with available subsurface investigation results. The resistance bias factors were evaluated for the tow static design methods by comparing the representative measured bearing capacities with the expected design values. Reliability analysis was performed by two types of advanced methods : the First Order Reliability Method (FORM), and the Monte Carlo Simulation (MCS) method using resistance bias factor statistics. As a result, when target reliability indices of the driven pipe pile were selected as 2.0, 2.33, 2.5, resistance factor of two design methods for SPT N at pile tip less than 50 were evaluated as 0.611~0.684, 0.537~0.821 respectively, and STP N at pile tip more than 50 were evaluated as 0.545~0.608, 0.643~0.749 respectively. The result from this research will be useful for developing various foundations and soil structures under LRFD.

A CLINICAL STUDY OF THE NASAL MORPHOLOGIC CHANGES FOLLOWING LEFORT I OSTEOTOMY (상악골 수평골절단술 후 비외형 변화에 관한 임상적 연구)

  • Bae, Jun-Soo;You, Jun-Young;Lyoo, Jong-Ho;Kim, Yong-Kwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.25 no.4
    • /
    • pp.324-329
    • /
    • 1999
  • The facial esthetics are much affected by nasal changes due to especially its central position in relation to facial outline and so appropriately evaluated should be the functional and esthetic aspects of the nose associated with the facial appearance. Generally, a maxillary surgical movement is known to induce the changes of nasolabial morphology secondary to the skeletal repositioning accompanied by muscular retraction. These changes can be desirable or undesirable to individuals according to the direction and amount of maxillary repositioning. We investigated the surgical changes of bony maxilla and its effects to nasal morphology through the analysis of the lateral cephalogram in the Le Fort I osteotomy. Subjects were 10 patients(male 2, female 8, mean age 22.3 years) and cephalograms were obtained 2 weeks before surgery(T1) and 6 months after surgery(T2). The surgical maxillary movement was identified through the horizontal and vertical repositioning of point A. Soft-tissue analysis of the nasal profile was performed employing two angles: nasal tip projection(NTP), columellar angle(CA). Also, alar base width(ABW) was assessed directly on the patients with a slide gauge. The results were as follows; 1. Both anterior and superior movement above 2mm of maxilla rotated up nasal tip above 1mm. Either anterior or superior movement above 2mm of maxilla made prediction of the amount & direction of NTP changes difficult. Especially, a correlation between horizontal movement of maxilla and NTP rotated-up was P<0.01. 2. Both much highly anterior and superior movement of maxilla is accompanied by more CA increase than either highly. Especially, the correlation between horizontal movement of maxilla and CA change was P<0.05. 3. Anterior and/or superior movement of maxilla was accompanied by the unpredictable ABW widening. 4. The amount of changes of NTP, CA, and ABW is not in direct proportion to amout of anterior and/or superior movement of maxilla. 5. Nasal morphologic changes following Le Fort I osteotomy are affacted by not merely bony repositioning but other multiple factors.

  • PDF

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

Effects of Green Manures and Complemental Fertilization on Growth and Nitrogen Use Efficiency of Chinese Cabbages Cultivated in Organic Systems (녹비작물과 추비방법이 유기재배 배추의 생육과 질소 이용효율에 미치는 영향)

  • Cho, Jung-Lai;An, Nan-Hee;Nam, Hong-Sik;Lee, Sang-Min
    • Korean Journal of Organic Agriculture
    • /
    • v.26 no.4
    • /
    • pp.731-743
    • /
    • 2018
  • This study was conducted to evaluate the effects of green manures and complemental fertilization with oil cake or liquid fertilizer on growth and nitrogen use efficiency of Chinese cabbage cultivated in organi systems. Field experiments were carried out at the National Institute of Agricultural Science in Suwon, South Korea from 2012 to 2014. Two green manure crops, Crotalaria and Hairy vetch, was cultivated in summer and in winter, respectively. The application methods of the green manure consisted of three tillage systems (overall tillage, partial tillage and no tillage). Oil cake and liquid fertilizer were used as complemental fertilizer. The results showed that when used as covering material in the upland soil without tillage, green manure fertilization was more effective in increasing growth and yield of Chinese cabbage than when incorporated into soil. It was possible to grow and harvest Chinese cabbage in the spring season by the application of hairy vetch as winter green manure. The higher yield of Chinese cabbage with green manure application was caused by the lower incidence rate of soft rot and tip-burn. The yield of the Chines cabbage that received green manure applications over two consecutive seasons followed by the supplemental fertilization with oil cake was similar to that of the conventional chemical fertilization. Following a single season green manure application in summer, however, the yield of cabbage was only about 70% of the conventional treatment. Green manure cultivation with additional liquid fertilization produced a yield similar to the conventional fertilization treatment, soil inorganic nitrogen concentration remained stable and the nitrogen use efficiency increased in the green manure applied soil. In conclusion, the organic cultivation of Chinese cabbage in the autumn season could be outperformed in the upland soil receiving two seasons (winter and summer) of green manure fertilization followed by the supplemental fertilization with liquid fertilizer.

Study on Bearing Capacity of Ultra High Strengh End Extended PHC Pile by Loading Test (재하시험을 통한 초고강도 선단확장 PHC말뚝의 적용성 연구)

  • Hwang, Ui-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.269-275
    • /
    • 2019
  • As the national industry is developing gradually due to the expansion of the economic scale, the construction of large and super high-rise structures for building social infrastructure has been increasing, and studies have been conducted actively to transmit the large loads at the upper portion to the lower bedrock. In this study, the PHC was extended to an ultra-high strength PHC, which increased the concrete compressive strength of the PHC from the conventional 80 MPa to 110 MPa, and the PHC, which extended the tip of the pile. After construction with the driving method and injected pile method, the tendency of the bearing capacity was tested through a load test. Measurements of the bearing capacity of the extended PHC using the pile driving method revealed the main surface friction force to be smaller than that of the general PHC, and the stet-up effect was also insignificant. On the other hand, the effect of the friction force on the ground surface when the injected pile method was applied is expected to increase the bearing capacity when the gap between the main surface and the ground is wide and the cement paste is filled tightly. In addition, the ultrahigh strength PHC showed higher bearing capacity than the conventional PHC, and the permissible pile stress was less than 60%. Therefore, it is possible to reduce the number of piles and reduce the construction cost and effect of shortening the length of the pile by designing the tip of the pile on the ground with the intensity of soft rock as a method for utilizing the increased strength of the ultra-high strength PHC.

Scale Effects and Field Applications for Continuous Intrusion Miniature Cone Penetrometer (연속관입형 소형콘관입시험기에 대한 크기효과 및 현장적용)

  • Yoon, Sungsoo;Kim, Kyu-Sun;Lee, Jin Hyung;Shin, Dong-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2359-2368
    • /
    • 2013
  • Cone penetration tests (CPTs) have been increasingly used for site characterizations. However, the site investigations using CPTs are often limited due to soil conditions depending on the cone size and capacity of the CPT system. The small sectional area of a miniature cone improves the applicability of the CPT system due to the increased capacity of the CPT system. A continuous intrusion system using a coiled rod allows fast and cost effective site investigation. In this study, the performance of the continuous intrusion miniature cone penetration test (CIMCPT) system has been evaluated by comparison tests with the standard CPT system at several construction sites in Korea. The results show that the CIMCPT system has a same performance with the CPT system and has advantages on the mobility and applicability. According to field verification tests for scale effect evaluation, the cone tip resistance evaluated by CIMCPT overestimates by 10% comparing to standard CPTs. A crawler mounted with the CIMCPT system has been implemented to improve accessibility to soft ground, and has shown improvement over the truck type CIMCPT system. Therefore, the improved CIMCPT system can be utilized as a cost effective and highly reliable soil investigation methodology to detect the depth of soft ground and to evaluate soil classification.