• Title/Summary/Keyword: Soft tissue model

Search Result 120, Processing Time 0.029 seconds

Coronary Arterial Lesions of Kawasaki Disease Observed in a Mouse Model of Sepsis: A Pilot Study and a Review of the Literature (패혈증 마우스 모델에서 가와사키병의 관상동맥 병변 관찰: 예비연구와 문헌고찰)

  • Kim, Joo-Hyun;Kim, Hyo-Jin;Shin, Jung-Ha;Choi, Ui-Yoon;Lee, Soo-Young;Han, Ji-Whan
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.2
    • /
    • pp.102-107
    • /
    • 2017
  • Purpose: Coronary arterial lesions (CALs) were reported to have developed in children with systemic inflammatory diseases, as well as those with Kawasaki disease (KD). The purpose of this study was to confirm that the CAL development in children with KD occurs in a mouse model of sepsis presenting typical systemic inflammatory response syndrome (SIRS). Methods: To induce the sepsis mouse model with SIRS, 6-week-old C57BL/6 mice were intraperitoneally injected with endotoxin. We compared histological findings of the major organs between the control and the sepsis groups and examined CAL in the heart of the septic mice. Results: Infiltrating inflammatory cells were relatively increased in the heart, liver, and kidneys of the sepsis group, compared with those of the control group. We confirmed lymphocytic infiltration in the myocardium (myocarditis) and the pericardial soft tissue of the heart. Furthermore, coronary artery of the septic mouse was identified, but CAL was not observed. Conclusions: In this study, we failed to confirm the existence of CAL in a mouse model of sepsis. However, it is well-known that CALs are seen in many kinds of diseases that cause SIRS. Our findings suggest further investigation into the clinical significance of CAL in various systemic inflammatory diseases, including KD.

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Repeated irradiation by light-emitting diodes may impede the spontaneous progression of experimental periodontitis: a preclinical study

  • Hyemee Suh;Jungwon Lee;Sun-Hee Ahn;Woosub Song;Ling Li;Yong-Moo Lee;Yang-Jo Seol;Ki-Tae Koo
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • Purpose: We investigated whether repeated irradiation with light-emitting diodes (LEDs) at a combination of 470 nm and 525 nm could suppress the progression of experimental periodontitis. Methods: A experimental periodontitis model was established in the second, third, and fourth premolars of the mandible in beagle dogs for 2 months. The spontaneous progression of periodontitis was monitored under the specified treatment regimen for 3 months. During this period, the animals were subjected to treatments of either plaque control only (control) or plaque control with LED application (test) at 2-week intervals. The clinical parameters included the probing pocket depth (PPD), gingival recession (GR), and the clinical attachment level (CAL). Histomorphometric analysis was performed using measurements of the length of the junctional epithelium, connective tissue (CT) zone, and total soft tissue (ST). Results: There were significant differences in PPD between the control and test groups at baseline and 12 weeks. When the change in PPD was stratified based on time intervals, it was shown that greater differences occurred in the test group, with statistical significance for baseline to 12 weeks, 6 to 12 weeks, and baseline to 6 weeks. There was no significant difference in GR between the control and test groups at any time points. Likewise, no statistically significant differences were found in GR at any time intervals. CAL showed a statistically significant difference between the control and test groups at baseline only, although significant differences in CAL were observed between baseline and 12 weeks and between 6 and 12 weeks. The proportion of CT to ST was smaller for both buccal and lingual areas in the control group than in the test group. Conclusions: Repeated LED irradiation with a combination of 470-nm and 525-nm wavelengths may help suppress the progression of periodontal disease.

Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model

  • Xuee Zhu;Jichen Wang;Dan Zhou;Chong Feng;Zhiwen Dong;Hanxiao Yu
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.641-648
    • /
    • 2019
  • Objective: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. Materials and Methods: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1-1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were rescanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. Results: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776-0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. Conclusion: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.

FABRICATION OF MYOMUCOSAL FLAP USING CULTURED ORAL EPITHELIUM IN RABBIT MODEL (가토모델에서 배양 구강상피를 이용한 근-점막 피판의 형성에 관한 연구)

  • Shin, Young-Min;Chung, Hun-Jong;Ahn, Kang-Min;Park, Hee-Jung;Sung, Mi-Ae;Kim, Soung-Min;Hwang, Soon-Jung;Kim, Myung-Jin;Jahng, Jeong-Won;Kim, Sung-Po;Yang, Eun-Kyung;Song, Kye-Yong;Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.226-237
    • /
    • 2005
  • Purpose : Extensive defect of oral and maxillofacial area is usually reconstructed with composite flap including skin paddle. However, if the defects are lined with only skin components, the mucosa's role in mastication and texture are not restored. Furthermore, stiffness and hair-growing prevent denture rehabilitation and good oral hygiene. This study was performed to overcome the disadvantages of composite soft tissue flaps including the skin and to make a model for myo-mucosal flaps. Materials and methods : Buccal mucosa sized $0.5\times1.0\;cm^2$ from New Zealand rabbit (around 1.5kg) was harvested and cultivated by the modification of Rheinwald and Green's keratinocyte culture method. Cultured mucosa was grafted on the fascia of latismus dorsi as form of mucosal sheet. After 7, 10, 14 days, the myomucosal flap was excised and evaluated under light microscope with H & E and immunohistochemical staining. As control group, harvested buccal mucosa from rabbit was transplanted to gracilis muscle(n=6). Results : From 7 days after prelamination, the basal layer of the grafted mucosa resembled that of normal mucosa. As control group, transplanted mucosa had original shape but there's slight inflammatory reaction. Prelaminated mucosa has 19.8$\pm$4.59 cell layers and some samples have more than 20 layers. The expression rate of PCNA was relatively strong (42.9%$\pm$14.1) at the basal layer of grafted mucosa and the laminin was found at the basal layer. On the contrary, prelaminated mucosa at 10 days showed moderate expression rate of PCNA(32.4%$\pm$4.62). We found the mucosal layer was somehow disappeared and there is strong inflammatory reaction. After 14 days prelamination, the grafted oral keratinocytes were almost disappeared and expression of PCNA was not observed. Conclusion : We can make 75 fold large mucosal($3850mm^2$) sheet from small samples of mucosa $(50mm^2)$. Epithelial sheet that grafted on the fascia of muscle underwent differentiation and proliferation. But after 10, 14 days, there was strong inflammatory reaction and the grafted mucosa was destroyed from surface layer. In rabbit model, transfer of fascio-mucosal flap should be done from 7 to 10 days after prelamination.

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method (유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발)

  • Park, Won-Pil;Woo, Dae-Gon;Ko, Chang-Yong;Lee, Qyoun-Jung;Lee, Yong-Heum;Choi, Seo-Hyoung;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.130-139
    • /
    • 2007
  • The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

Effects of Maxillary Lateral Incisor Agenesis on Skeletodental Characteristics in Mixed Dentition (상악 측절치 결손이 어린이 안면골격과 치열궁 형태에 미치는 영향)

  • Nam, Siyeon;Shin, Jonghyun;Kim, Jiyeon;Jeong, Taesung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.147-157
    • /
    • 2019
  • This study aimed to evaluate skeletodental characteristics of patient with maxillary lateral incisor agenesis (MLIA) in mixed dentition. It involved the children in early mixed dentition who visited Pusan National University dental hospital for orthodontic purposed and had intact primary canines. 38 children with MLIA and 38 controls with the same chronological age satisfying the inclusion criteria were selected. The craniofacial structures and dental arch dimensions of the MLIA were evaluated using model & cephalometric analysis and compared to controls. The rate of unilateral MLIA was high in male and the rate of bilateral MLIA was high in female. In model analysis, the width / length ratio of maxillary anterior portion of the MLIA group were higher and arch perimeter of the maxilla of the MLIA group were smaller than those of the control group (p = 0.003, 0.04). Cephalometric analysis showed that there were no significant differences in terms of skeletal, dental analysis. In soft tissue profile, nasolabial angle was larger in MLIAs than in controls (p = 0.039). Considering these skeletodental characteristics of MLIA, early diagnosis and proper management is highly recommended to minimize the possibility of functional defect.

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

IMPLANT INSTALLATION USING VERTICAL DISTRACTION OSTEOGENESIS AT A SEVERELY ATROPHIED EDENTULOUS MANDIBLE (심하게 위축된 하악골의 완전 무치악 환자에서의 수직 골신장술을 이용한 임플란트 치료)

  • Yeom, Hak-Ryol;Jeon, Seung-Ho;Kim, Yoon-Tae;Paeng, Jun-Young;Ahn, Kang-Min;Myung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.154-165
    • /
    • 2006
  • Objectives : It is difficult to place implants at a severely atrophied edentulous mandible because of vertical and horizontal alveolar defect. The autogenous and allogenic bone graft and guided bone regeneration are useful, but there are some limitations such as the resorption and infection of the grafted bone, and insufficiency of soft tissue. Distraction osteogenesis has recently evolved a challenging technique to overcome major draws of conventional augmentation procedures, we, therefore, report the four applications of implant placement after vertical alveolar distraction osteogenesis. Patients and Methods : Four patients(all female, mean age: $60{\pm}6$ years) with severe alveolar ridge deficiencies at their anterior mandible were treated with vertical alveolar distraction osteogenesis by intraoral device(Track 1.5, 15 mm model, KLS Martin, Tuttlingen, Germany) and placement of implants (Branemark MK III, TiUnite). After the latency periods of 5, 7, 8 days, distraction rhythm and rate were $0.5\;mm{\times}2\;times/day$ in the case of good bone quality, and $0.25\;mm{\times}3\;times/day$ in the case of poor bone quality. After consolidation periods of mean fifteen weeks, five implants for each patients were placed at the interforaminal area. Results : On average, a vertical gain of $11.38{\pm}1.38\;mm$ was obtained by distraction. And all distraction zone showed complete ossification by panoramic radiography. There were no postoperative complications other than numbness of lower lip in one case. Total twenty implants in four patients were placed and their outcomes were satisfactory. Conclusion : It is a useful method to place five implants after vertical distraction osteogenesis of the severely atrophied mandible for the implant-supported fixed prosthesis.