• Title/Summary/Keyword: Soft tissue model

Search Result 119, Processing Time 0.029 seconds

Development of a nonlinear biomechanical soft tissue model for a virtual surgery trainer (가상수술기를 위한 비선형 생체 모델의 개발)

  • Kim J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.911-914
    • /
    • 2005
  • Soft tissue characterization and modeling based on living tissues has been investigated in order to provide a more realistic behavior in a virtual reality based surgical simulation. In this paper, we characterize the nonlinear viscoelastic properties of intra-abdominal organs using the data from in vivo animal experiments and inverse FE parameter estimation algorithm. In the assumptions of quasi-linear-viscoelastic theory, we estimated the nonlinear material parameters to provide a physically based simulation of tissue deformations. To calibrate the parameters to the experimental results, we developed a three dimensional FE model to simulate the forces at the indenter and an optimization program that updates new parameters and runs the simulation iteratively. The comparison between simulation and experimental behavior of pig intra abdominal soft tissue are presented to provide a validness of the tissue model using our approach.

  • PDF

Plantar Soft-tissue Stress states in standing: a Three-Dimensional Finite Element Foot Modeling Study

  • Chen, Wen-Ming;Lee, Peter Vee-Sin;Lee, Tae-Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.197-204
    • /
    • 2009
  • It bas been hypothesized that foot ulceration might be internally initiated. Current instruments which merely allow superficial estimate of plantar loading acting on the foot, severely limit the scope of many biomechanical/clinical studies on this issue. Recent studies have suggested that peak plantar pressure may be only 65% specific for the development of ulceration. These limitations are at least partially due to surface pressures not being representative of the complex mechanical stress developed inside the subcutaneous plantar soft-tissue, which are potentially more relevant for tissue breakdown. This study established a three-dimensional and nonlinear finite element model of a human foot complex with comprehensive skeletal and soft-tissue components capable of predicting both the external and internal stresses and deformations of the foot. The model was validated by experimental data of subject-specific plantar foot pressure measures. The stress analysis indicated the internal stresses doses were site-dependent and the observation found a change between 1.5 to 4.5 times the external stresses on the foot plantar surface. The results yielded insights into the internal loading conditions of the plantar soft-tissue, which is important in enhancing our knowledge on the causes of foot ulceration and related stress-induced tissue breakdown in diabetic foot.

An Optimized Model for the Local Compression Deformation of Soft Tissue

  • Zhang, Xiaorui;Yu, Xuefeng;Sun, Wei;Song, Aiguo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.671-686
    • /
    • 2020
  • Due to the long training time and high training cost of traditional surgical training methods, the emerging virtual surgical training method has gradually replaced it as the mainstream. However, the virtual surgical system suffers from poor authenticity and high computational cost problems. For overcoming the deficiency of these problems, we propose an optimized model for the local compression deformation of soft tissue. This model uses a simulated annealing algorithm to optimize the parameters of the soft tissue model to improve the authenticity of the simulation. Meanwhile, although the soft tissue deformation is divided into local deformation region and non-deformation region, our proposed model only needs to calculate and update the deformation region, which can improve the simulation real-time performance. Besides, we define a compensation strategy for the "superelastic" effect which often occurs with the mass-spring model. To verify the validity of the model, we carry out a compression simulation experiment of abdomen and human foot and compare it with other models. The experimental results indicate the proposed model is realistic and effective in soft tissue compression simulation, and it outperforms other models in accuracy and real-time performance.

Evaluation of the mandibular asymmetry using the facial photographs and the radiographs (방사선사진과 안모사진을 이용한 하악 비대칭의 평가)

  • Lee Sul-Mi
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.199-204
    • /
    • 2001
  • Purpose : To assess the relationship between soft tissue asymmetry and bone tissue asymmetry using the standardized photographs and the posteroanterior (PA) cephalometric radiographs in mandibular asymmetric patients. And to clarify that the lack of morphologic balance among different skeletal components can often be masked by compensatory soft tissue contributions. Methods: Experimental group consisted of 58 patients whose chief complaints were facial asymmetry, they were taken with standardized facial photographs and PA cephalometric radiographs. Control group consisted of 30 persons in the normal occlusion. The reproducibility of the facial photograph was confirmed by model test. The differences of fractional vertical heightand horizontal width from standardized facial photographs and PA cephalometric radiographs were compared and analyzed. Results: The difference of fractional vertical bone height was 0.63 and fractional vertical soft height was 0.58 in control group, 3.10 and 2.01 in asymmetric group, respectively. The difference of fractional horizontal bone width was 0.52 and fractional horizontal soft width was 0.70 in control group, 2.51 and 1.70 in asymmetric group, respectively. Both soft and bone tissue showed significant difference between control and asymmetric group (p<0.05). The difference of bone tissue was greater than that of soft tissue (p<0.05) in the experimental group but, not in control group. Conclusions: Soft tissue components may compensate for underlying skeletal imbalances.

  • PDF

A Study on New Invention Model of Handy Deep Friction Massager${(R)}$ by Using DFM (DFM 원리를 이용한 휴대용 Deep Friction Massager${(R)}$ 치료기기 모형개발에 관한 연구)

  • Park, Jj-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • The main purpose of this article is to make a handy Deep Friction Massager by using DFM in based on Dr. Cyriax's manual medicine. Also this study's aimed to heal soft tissue lesions - low back pain, neck pain, tennis elbow, golfer's elbow, frozen shoulder, myofibrosis etc. - which has resolved adhesion scar tissue problem in soft tissue. The results of this study were as followings ; 1. Deep friction massager has a effect not only massage but also healing, because it is broken the physiologic bridge of scar tissue in soft tissue. 2. It is possible to reduce the fatigue and effort of therapists during the deep friction massage. 3. Deep friction massager is made of handy form, so it is very convenient of using and application to patients.

  • PDF

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

  • Kim, Min-Sung;Kim, Bok-Yeol;Choi, Hwa-Young;Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Hee;Lee, Sae-Rom;Kang, Ju-Han;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Purpose: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. Materials and Methods: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. Results: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Conclusion: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

Soft and Hard Tissue Augmentation with/without Polydeoxyribonucleotide for Horizontal Ridge Deficiency: A Pilot Study in a Dog Model

  • Hyunwoo Lim;Yeek Herr;Jong-Hyuk Chung;Seung-Yun Shin;Seung-Il Shin;Ji-Youn Hong;Hyun-Chang Lim
    • Journal of Korean Dental Science
    • /
    • v.17 no.2
    • /
    • pp.53-63
    • /
    • 2024
  • Purpose: To investigate the effects of simultaneous soft and hard tissue augmentation and the addition of polydeoxyribonucleotide (PDRN) on regenerative outcomes. Materials and Methods: In five mongrel dogs, chronic ridge defects were established in both mandibles. Six implants were placed in the mandible, producing buccal dehiscence defects. The implants were randomly allocated to one of the following groups: 1) control: no treatment; 2) GBR: guided bone regeneration (GBR) only; 3) GBR/PDRN: GBR+PDRN application to bone substitute particles; 4) GBR/CTG: GBR+connective tissue grafting (CTG); 5) GBR/VCMX: GBR+soft tissue augmentation using volume stable collagen matrix (VCMX); and 6) group GBR/VCMX/PDRN: GBR+VCMX soaked with PDRN. The healing abutments were connected to the implants to provide additional room for tissue regeneration. Submerged healing was achieved. The animals were euthanized after four months. Histological and histomorphometric analyses were then performed. Results: Healing abutments were gradually exposed during the healing period. Histologically, minimal new bone formation was observed in the dehiscence defects. No specific differences were found between the groups regarding collagen fiber orientation and density in the augmented area. No traces of CTG or VCMX were detected. Histomorphometrically, the mean tissue thickness was greater in the control group than in the other groups above the implant shoulder (IS). Below the IS level, the CTG and PDRN groups exhibited more favorable tissue thickness than the other groups. Conclusion: Failure of submerged healing after tissue augmentation deteriorated the tissue contour. PDRN appears to have a positive effect on soft tissues.

Virtual Environments for Medical Training: Soft tissue modeling (의료용 훈련을 위한 가상현실에 대한 연구)

  • Kim, Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.372-377
    • /
    • 2007
  • For more than 2,500 years, surgical teaching has been based on the so called "see one, do one, teach one" paradigm, in which the surgical trainee learns by operating on patients under close supervision of peers and superiors. However, higher demands on the quality of patient care and rising malpractice costs have made it increasingly risky to train on patients. Minimally invasive surgery, in particular, has made it more difficult for an instructor to demonstrate the required manual skills. It has been recognized that, similar to flight simulators for pilots, virtual reality (VR) based surgical simulators promise a safer and more comprehensive way to train manual skills of medical personnel in general and surgeons in particular. One of the major challenges in the development of VR-based surgical trainers is the real-time and realistic simulation of interactions between surgical instruments and biological tissues. It involves multi-disciplinary research areas including soft tissue mechanical behavior, tool-tissue contact mechanics, computer haptics, computer graphics and robotics integrated into VR-based training systems. The research described in this paper addresses the problem of characterizing soft tissue properties for medical virtual environments. A system to measure in vivo mechanical properties of soft tissues was designed, and eleven sets of animal experiments were performed to measure in vivo and in vitro biomechanical properties of porcine intra-abdominal organs. Viscoelastic tissue parameters were then extracted by matching finite element model predictions with the empirical data. Finally, the tissue parameters were combined with geometric organ models segmented from the Visible Human Dataset and integrated into a minimally invasive surgical simulation system consisting of haptic interface devices and a graphic display.

  • PDF

An Optimized Mass-spring Model with Shape Restoration Ability Based on Volume Conservation

  • Zhang, Xiaorui;Wu, Hailun;Sun, Wei;Yuan, Chengsheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1738-1756
    • /
    • 2020
  • To improve the accuracy and realism of the virtual surgical simulation system, this paper proposes an optimized mass-spring model with shape restoration ability based on volume conservation to simulate soft tissue deformation. The proposed method constructs a soft tissue surface model that adopts a new flexion spring for resisting bending and incorporates it into the mass-spring model (MSM) to restore the original shape. Then, we employ the particle swarm optimization algorithm to achieve the optimal solution of the model parameters. Besides, the volume conservation constraint is applied to the position-based dynamics (PBD) approach to maintain the volume of the deformable object for constructing the soft tissue volumetric model base on tetrahedrons. Finally, we built a simulation system on the PHANTOM OMNI force tactile interaction device to realize the deformation simulation of the virtual liver. Experimental results show that the proposed model has a good shape restoration ability and incompressibility, which can enhance the deformation accuracy and interactive realism.