• Title/Summary/Keyword: Soft starting algorithm

Search Result 9, Processing Time 0.025 seconds

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Soft Start-up Algorithm of Single-Phase Induction Motor Based on Full-bridge Inverter (풀 브리지 인버터 기반 단상 유도전동기의 소프트 기동 기법)

  • Kim, Tae-Seong;Kang, Hyung-Do;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.258-265
    • /
    • 2018
  • This paper proposes an algorithm for reducing the starting current when the single-phase induction motor starts and analyzes its operation. Generally, the single-phase induction motors require several starters to generate the starting torque due to their structural characteristics. In this paper, a capacitor-start / capacitor-run method of the single-phase induction motor is basically adopted. This conventional method is efficient and has a large starting torque, but it generates about 5 ~ 6 times of inrush current at startup. As a result, the freezer starting device and peripheral devices are damaged and life time may be reduced. To reduce the inrush current, the current control algorithm based on the virtual dq model is presented to control the starting current. In addition, it validates the proposed algorithm through experiments to smooth transit from start-up operation to the rated operating region.

Sensorless Fuzzy Logic Soft Start of Induction Motor With Load Detection

  • Arehpanahi, Mehdi;Monfared, Jafar Mili;Abbaszadeh, Karim
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2378-2381
    • /
    • 2003
  • In recent years, fuzzy logic has received greater emphasis in the field of power electronics and motion control by virtue of its adaptive capability. A new fuzzy logic based soft-start scheme for induction motor drives close to load detection has been discussed here using microcontroller based thyristorised voltage controller. Rule based soft-start algorithm is fully realised through a software approach only. The soft-start strategy is based on the change of input impedance during starting period. The prototype has been tested under various loading conditions and found to be reliable.

  • PDF

Simple Digital LCD Backlight Inverter using a Single-chip Microcontroller (단일칩 마이크로컨트롤러를 이용한 간단한 디지털 LCD 백라이트 인버터)

  • Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.461-468
    • /
    • 2010
  • This paper presents a simple digital LCD backlight inverter using a single-chip microcontroller. The proposed inverter reduces the ignition voltage and eliminates the current spikes and hence improves the ignition behavior of the cold cathode fluorescent lamp(CCFL). Thus it increases the CCFL's life span. This is achieved by implementing a digital dimming control algorithm, that contains the soft-starting algorithm, all on a single-chip microcontroller. The inverter utilizes the full-bridge resonant circuit topology. The design example along with a simple analysis for the inverter is shown, and the experimental results of the designed prototype results in close agreement with the theoretical analysis and explanation. The overall system's power efficiency is approximately 85%. Compared with conventional inverters, the ignition voltage is reduced by around 30% without any lamp current spike occurring during the dimming control operation.

Development of A Digital Controller for The Metal Halide Lamp Ballast (메탈할라이드 램프 안정기의 디지털 제어기 개발)

  • Moon, Tae-Hwan;Kim, Hee-Jun;Cho, Kyu-Min;Kim, Myong-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1113-1116
    • /
    • 2001
  • This paper presents a digital controller of electronic ballast for the metal halide lamp. The proposed controller includes the control algorithm for soft starting, no load protection, overcurrent protection and dimming(or power control). The proposed controller, moreover, has the high frequency modulation scheme and the tracking algorithm to avoid acoustic resonance phenomena. For the math production with the low cost using the ASICs, the proposed controller has been designed with the EPLDs only, without any microprocessor. In this paper, the proposed control algorithms are described and the experimental results of prototype 150W metal halide electronic ballast are presented.

  • PDF

Novel LCD CCFL-backlight Electronic Ballast using the Phase-shift Full-bridge Inverter (위상천이 풀브리지 인버터를 이용한 새로운 LCD CCFL 백라이트 전자식 안정기)

  • Jeong, Gang-Youl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.8-17
    • /
    • 2010
  • This paper proposes a novel LCD CCFL-backlight electronic ballast using the phase-shift full-bridge inverter. The proposed electronic ballast reduces the ignition voltage and eliminates current spikes using the new digital dimming control applied with soft-starting. Thus the electronic ballast improves ignition behavior of the CCFL and hence increases the CCFL's life span. For this, this paper analyzes the full-bridge inverter topology of the proposed electronic ballast and explains the new digital dimming control algorithm applied to the ballast, briefly. And this paper shows a design example of the prototype circuit and explains an implementation method of the digital dimming control which is implemented on a single-chip microcontroller with software. This was implemented as actual prototype electronic ballast, and its experimental results showed that the proposed electronic ballast operates correctly. The ignition voltage of the prototype in the digital dimming operation was reduced about 30[%] compared with the conventional electronic ballast and there were not any current spikes.

A Study on Control Algorithm of a Switching Device for Junction of Photovoltaic Modules by Using Soft Starting (소프트 스타팅을 이용한 태양광모듈 접속장치용 스위칭 소자의 제어기법에 관한 연구)

  • Kim, Eun-Soo;Ha, Yong-Ho;Hwang, Seon-Hwan;Lee, Jaeseok
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.306-307
    • /
    • 2017
  • 본 논문에서는 태양광모듈과 전력변환장치간의 접속장치로 사용된 전력용 반도체 스위칭 소자의 소프트 스타팅 기법을 통해 초기 돌입전류를 저감하는 알고리즘을 제안하고자 한다. 태양광 모듈의 경우, 릴레이나 DC차단기 등을 사용하여 전력변환장치와 연동하는 것이 일반적이나, 이 경우 태양광모듈의 수명과 접속장치의 전압 강하 및 응답성 등의 문제를 야기한다. 또한, 전력변환장치 출력단의 커패시터에 초기 동작 시 과도한 동일전류가 발생하게 되고 이는 태양광모듈의 과전류 현상을 발생시켜 모듈의 수명과 더불어 퓨즈의 차단 및 발열 등 비이상적인 현상을 발생시킨다. 따라서, 본 논문에서는 이러한 문제점을 해결하고자 스위칭 소자를 사용한 접속장치 적용하였고, 소프트 스타팅 기법을 이용하여 돌입전류를 저감하고자 한다. 제안한 알고리즘의 경우, 시뮬레이션을 통해서 검증하고자 한다.

  • PDF

Initial Rotor Polarity Detection of Single-phase Permanent Magnet Synchronous Motor Based on Virtual dq-axis (단상 영구자석 동기 전동기의 가상 dq축 기반 초기 회전자 자극 검출)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1004-1010
    • /
    • 2020
  • This paper proposes an initial rotor magnetic pole detection method for single-phase permanent magnet synchronous motors. The target motor cannot obtain position information based on the back emf in the low speed and stop state. Therefore, an open loop starting process is required, and in this process, initial rotor position information for low current and soft start is need. The proposed initial rotor magnetic pole detection algorithm considers the effect of asymmetric air- gap and magnetic flux. In addition, the high-frequency voltage signal injection and the offset voltage for accurate detection is used. As a result, the permanent magnet poles are is determined by acquiring the maximum value of the induced current using the virtual dq-axis.

(Development of A Digital Controller of The Electronic Ballast using High Frequency Modulation Method for The Metal Halide Lamp) (메탈 할라이드 램프용 고주파 변조 방식 전자식 안정기의 디지털 제어기 개발)

  • O, Deok-Jin;Kim, Hui-Jun;Jo, Gyu-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.228-238
    • /
    • 2002
  • This paper presents a digital controller of the electronic ballast using high frequency modulation method for the metal halide lamp. The proposed controller includes the control algorithm for soft starting, no load protection, over current protection and power control. The proposed digital controller, moreover, has the high frequency modulation scheme and the tracking algorithm to avoid acoustic resonance phenomena. For the math production with the low cost using the ASICs (Application Specific Integrated Circuit), the proposed digital controller has been designed with the FPGAs(Field Programmable Gate array) only, without any microprocessor. In this paper, the detail digital control algorithms are described and the experimental results of prototype 150w metal halide electronic ballast are presented.