• Title/Summary/Keyword: Soft foreign body

Search Result 57, Processing Time 0.023 seconds

Successful Localization of Intraoral Foreign Body with C-arm Fluoroscopy

  • Kang, Young-Hoon;Byun, June-Ho;Choi, Mun-Jeong;Park, Bong-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.5
    • /
    • pp.219-223
    • /
    • 2014
  • During surgical procedures, unexpected material, including surgical instruments and tissue segments, may get lost in the surgical field. Most of these should be immediately removed to prevent further complications, such as vital organ irritation, infection, and inflammatory pseudo-tumor formation. However, it is not always easy to define the exact location of the foreign body, especially if the item is very small and/or it is embedded in the soft tissue of the head and neck region. Intraoperative real-time radiological imaging with C-arm fluoroscopy can be useful to trace the three-dimensional location of small and embedded foreign bodies in the oral and maxillofacial area. We describe an unusual case of an embedded micro-screw in the intrinsic tongue muscle that had been dropped into the sublingual space during a lower alveolar bone graft procedure. The lost foreign body was accurately identified with C-arm fluoroscopy and safely removed without any further complications.

120 Cases of Facial Foreign Body Granuloma (안면부 이물 육아종 120례의 치험례)

  • Park, Tae-Hwan;Seo, Sang-Won;Kim, June-Kyu;Chang, Choong-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.233-238
    • /
    • 2010
  • Purpose: As the use of soft tissue fillers becomes more popular, complications such as foreign body granuloma (FBG) are increasing. We report 120 cases of facial FBG and review the available literatures. Methods: 120 patients of facial FBG in our clinic from Mar. 2003 to Feb. 2008 were complied and analyzed. A retrospective chart review was done and patient satisfaction was evaluated with a questionnaire using 5 score scale. Patients with severe inflammation sign or bizarre deformity underwent surgical excision and those with minimal symptoms or a history of hyaluronic acid injection received injection therapy using hyaluronidase. Results: 100 females and 20 males were observed. The average age was 43.7 years (from 16 to 74). 84 patients received surgical therapy and 36, injection therapy. Deformity of facial contour, foreign body sensation and inflammation sign were the three main chief complaints. 84 patients did not know what the injection materials were. The known materials are as follows: collagen, hyaluronic acid, silicone oil, paraffin. 92 cases were performed by unlicensed practitioners, 29 by physicians. Anatomical site most frequently affected by the foreign body granuloma was the cheek (25.8%), followed by forehead (19.2%), lips (15.8%), nose (9.2%), mentum (8.3%), eyelid and eyebrow (4.3%) and temple (0.8%). In 21 patients (17.5%), FBGs were found on multiple sites. Patients with inflammation sign got the highest satisfaction ($3.19{\pm}0.73$) (p=0.001) among 3 chief complaints. And patient satisfaction was statistically higher in surgical therapy group ($3.43{\pm}0.72$) than in injection therapy group ($2.97{\pm}0.88$) (p=0.003). Conclusion: We suggest that it may be beneficial to tailor the type of treatment for FBG relying on wound state and patient's chief complaints. In surgical therapy, resolute approach is necessary to correct facial deformity definitely and to minimize inflammation. Injection therapy could be another option for those with minimal symptoms or a history of hyaluronic acid injection. To prevent foreign body granuloma, not only plastic surgeons but also other physicians should inject soft tissue fillers with great caution and we should warn the public of disastrous consequences associated with illegal medical practice.

The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

The Status of Soft Contact Lens Wear in College Students in Korea (한국 대학생들의 소프트 콘택트렌즈 착용에 대한 실태)

  • Kim, Douk-Hoon;Kim, Joung-Suk;Mun, Joung-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.233-239
    • /
    • 2004
  • This study investigated the status of soft contact lens wear in college students. The results were as follows: 1. The most prevalent age of initial contact lens wear was 19 years or 20 years, with an age distribution in females from as early as 10 years to 20 years. 2. For almost all subjects, the test clinic for the contact lens wear assessment and purchase of the contact lenses was an optical shop. 3. The main advantage for most male subjects was use for sports, whereas most female subjects used contact lenses for cosmetic reasons. 4. The most common side-effects experienced due to contact lens wear were red eye, foreign body sensation, and eye pain. 5. The most frequently reported eye disease caused by contact lens wear was conjunctivitis, with only few subjects experiencing keratitis. 6. Following treatment for the side effects of contact lens wear, most subjects hoped to re-use the previous contact lenses, some subjects wanted to change to new contact lenses, and others subjects refused further contact lens wear.

  • PDF

CT Number Measurement of Residual Foreign Bodies in Face (안면부에 잔류된 다양한 이물질을 측정한 CT 계수)

  • Wee, Syeo Young;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Calcifying Fibrous Tumor Mimicking a Foreign Body of the Stomach: A Case Report (위 내 이물로 오인한 석회화 섬유 종양 1예)

  • Jeong, Ji-Eun;Lee, Kyung-Hun;Sung, Hyun-Jung;Cho, Chang-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.1
    • /
    • pp.57-63
    • /
    • 2009
  • Calcifying fibrous tumors (CFTs) are unusual benign tumors of childhood, located primarily in soft tissues, pleura, and peritoneum. The cause and pathogenesis are unclear. We report a rare case of a CFT in a 2-year-old boy who presented with vomiting and abdominal distension. An abdominal X-ray showed an elliptical, calcific shadow in the LUQ area mimicking a foreign body. An internally protruding mass along the lesser curvature of the gastric body was an incidental finding during upper endoscopy, biopsies of which were negative. Abdominal CT showed a 4.5${\times}$3.2 cm soft tissue mass of the gastric wall with calcifications. A diagnosis of gastric submucosal mass was suspected and a wedge resection of the stomach was performed. On microscopic examination, the tumor was composed of whorls of dense hyalinized collagen bundles with a few fibroblasts. There were also amorphous dystrophic calcifications and nodular aggregates of mononuclear inflammatory cells. Immunohistochemically, spindle cells did not stain for anaplastic lymphoma kinase-1 (ALK-1), CK, smooth muscle actin (SMA), or desmin. Taken together, the mass was compatible with a CFT of the gastric wall. This is the first reported case of CFT in a Korean child.

  • PDF

Analysis on the design characteristics of blouse for silver generation in domestic and foreign (실버 세대를 위한 국내·외 블라우스에 나타난 디자인 특성 분석)

  • Kim, Da Eun;Lee, Kyoung Hee
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.1
    • /
    • pp.32-44
    • /
    • 2015
  • Increasing of Korean old women's rate is demographic characteristics attributed an aging society, silver generation would lead to silver fashion market with steady competitiveness and interest in fashion. So the study attempts to use foundation material for silver's fashion design by analyzing design characteristics and processing development of design representative women's top. Selecting brand for collecting photo using study represents a mid- and premium-priced with reference Brand Yearbook. After selecting brand on domestic and foreign I have collected picture from Internet shopping mall and web-site of fashion brand, from October 2013 to July 2014, but I selected 840 pictures based on front poses for easy decision. In order to search design characteristics according to sort of silver blouse design on domestic and foreign. I have examined shape, color, pattern, fabric sensation, inside composition line and decoration with reference standard of analysis in preceding research. Data analysis method was conducted on analysis of frequency and cross analysis using SPSS statistical package 21.0. The conclusion of design characteristic according to type of blouse design for silver, H-silhouette in shirt blouse seems to fit in body transformation and expose silhouette with correcting the body flaw. Using soft material in T-shirt blouse they are able to conceal a body defect and express beautiful silhouette. By using detail in pullover shirt blouse and tunic blouse for point of design, it express glamour and luxurious. Most of blouse are printed various pattern, it would looks more gorgeous using pattern.

Ultrasonographic and Computed Tomographic Appearance of Spontaneous Cutaneous Fistula Resulted from Retained Surgical Gauze in a Dog

  • Hwang, Tae-sung;Huh, Chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.36 no.4
    • /
    • pp.238-243
    • /
    • 2019
  • A 6-year-old, spayed female Maltese was presented with the condition of a chronic recurrent abscess formation in the left flank region. Despite the antibiotics and drainage therapy given to the dog, the lesion formed a continued serosanguineous to the point that a purulent discharge was evident. In the meantime, an abdominal ultrasound revealed the presence of a well-defined mass with a hypoechoic outer margin, and a hyperechoic inner rim in the cranial of the kidney. A fistula was noted as being present with a connection between the subcutaneous lesion of the left flank and the abdominal mass. It is emphasized that CT scans revealed the existence of a soft tissue dense mass with low attenuation area, as seen in some internal areas and also a peripheral contrast enhancement was noted within a nonenhancing central region. There was additional nonenhancing fluid found dorsal to the inflammatory tract passing under the epaxial muscles and at the peritoneum. Likewise, the tract exited the skin surface in the left flank. A tentative diagnosis of an abdominal abscess with spontaneous cutaneous fistula was made based on the ultrasonographic and CT appearances. A foreign body such as surgical gauze should always be considered a potential cause of draining tract in small animals, as was considered to be the problem in this case.

Improvement of biohistological response of facial implant materials by tantalum surface treatment

  • Bakri, Mohammed Mousa;Lee, Sung Ho;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.52.1-52.8
    • /
    • 2019
  • Background: A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods: Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results: The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion: Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.

Separation of tip from the bipolar radiofrequency system in the arthroscopic surgery - Case Report - (Bipolar radiofrequency system 사용 중 발생한 Tip의 분리 - 증례 보고 -)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Park, Ji-Kang;Bae, Seung-Whan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.66-68
    • /
    • 2008
  • Recently, devices using radiofrequency energy have been developed for arthroscopic soft tissue ablation, cauterization and shrinkage. After ACL reconstruction operation, articular metallic foreign body was found in the post-operative radiographs. It was proven to be the tip of bipolar radiofrequency system after foreign body removal. After that we experienced 2 more cases during the acromioplasty procedure. We requires attention to prevent the separation of the tip from the body in the arthroscopic surgery using bipolar radiofrequency system.

  • PDF