• Title/Summary/Keyword: Soft engineering

Search Result 3,307, Processing Time 0.029 seconds

An Analytical Study on the Determination of Reinforcement Length of Pile Slab Method (Pile Slab 공법의 보강길이 산정에 관한 해석적 연구)

  • Lee, Young-Keun;Park, Choon-Sik;Lee, Chae-Gun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1232-1238
    • /
    • 2008
  • From the result of analysis using finite element method for the Pile Slab reinforcement length through embankment of height, soft ground and the change of cohesion following results were acquired. 1. The higher embankment of height is, the deeper depth of soft ground is, the smaller cohesion is, Pile Slab reinforcement length increased almost straight. 2. The reinforcement length is controlled by the depth of soft ground, cohesion, embankment of height and the like. Among these, cohesion of soft ground is affected the most. 3. The reinforcement length of Pile Slab is determined using by calculated formula.

  • PDF

A Comparative Study on Soft Switching Method of Single Stage AC/DC Full-Bridge Converter (단일전력단으로 구성된 역률 보상 AC/DC Full-Bridge Converter의 소프트 스위칭 기법에 대한 비교 연구)

  • Lee S. R.;Jeon C. H.;Jeong C. G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.694-697
    • /
    • 2001
  • A optimal soft switching technique for A/DC full bridge converter is proposed. variable soft switching single stage AC/DC full bridge converter with unit power factor are presented in this paper. Using soft switching, we can reduce a switching losses. As a result, achieving good power factor and achieving a good efficiency. We search a optimal soft switching technique in this paper and to verify the theoretical analysis of the presented AC/DC full bridge converter, a design example is given with its Pspice and Psim simulation and experimental results.

  • PDF

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Identifying stiffness irregularity in buildings using fundamental lateral mode shape

  • Vijayanarayanan, A.R.;Goswami, Rupen;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.437-448
    • /
    • 2017
  • Soft or extreme soft storeys in multi-storied buildings cause localized damage (and even collapse) during strong earthquake shaking. The presence of such soft or extremely soft storey is identified through provisions of vertical stiffness irregularity in seismic design codes. Identification of the irregularity in a building requires estimation of lateral translational stiffness of each storey. Estimation of lateral translational stiffness can be an arduous task. A simple procedure is presented to estimate storey stiffness using only properties of fundamental lateral translational mode of oscillation (namely natural period and associated mode shape), which are readily available to designers at the end of analysis stage. In addition, simplified analytical expressions are provided towards identifying stiffness irregularity. Results of linear elastic time-history analyses indicate that the proposed procedure captures the irregularity in storey stiffness in both low- and mid-rise buildings.

Successive Approximated Log Operation Circuit for SoftMax in CNN (CNN의 SoftMax 연산을 위한 연속 근사 방식의 로그 연산 회로)

  • Kang, Hyeong-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.330-333
    • /
    • 2021
  • In a CNN for image classification, a SoftMax layer is usually placed at the end. The exponentinal and logarithmic operations in the SoftMax layer are not adequate to be implemented in an accelerator circuit. The operations are usually implemented with look-up tables, and the exponential operation can be implemented in an iterative method. This paper proposes a successive approximation method to calculate a logarithm to remove a very large look-up table. By substituing the large table with two very small tables, the circuit can be reduced much. The experimental results show that the 85% area reduction can be reached with a small error degradation.

SoftMax Computation in CNN Using Input Maximum Value (CNN에서 입력 최댓값을 이용한 SoftMax 연산 기법)

  • Kang, Hyeong-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.2
    • /
    • pp.325-328
    • /
    • 2022
  • A convolutional neural network(CNN) is widely used in the computer vision tasks, but its computing power requirement needs a design of a special circuit. Most of the computations in a CNN can be implemented efficiently in a digital circuit, but the SoftMax layer has operations unsuitable for circuit implementation, which are exponential and logarithmic functions. This paper proposes a new method to integrate the exponential and logarithmic tables of the conventional circuits into a single table. The proposed structure accesses a look-up table (LUT) only with a few maximum values, and the LUT has the result value directly. Our proposed method significantly reduces the space complexity of the SoftMax layer circuit implementation. But our resulting circuit is comparable to the original baseline with small degradation in precision.

FILTERS OF RESIDUATED LATTICES BASED ON SOFT SET THEORY

  • JUN, YOUNG BAE;LEE, KYOUNG JA;PARK, CHUL HWAN;ROH, EUN HWAN
    • Communications of the Korean Mathematical Society
    • /
    • v.30 no.3
    • /
    • pp.155-168
    • /
    • 2015
  • Strong uni-soft filters and divisible uni-soft filters in residuated lattices are introduced, and several properties are investigated. Characterizations of a strong and divisible uni-soft filter are discussed. Conditions for a uni-soft filter to be divisible are established. Relations between a divisible uni-soft filter and a strong uni-soft filter are considered.

Soft Actuator Development for Artificial Muscle (인공근육개발을 위한 소프트 액추에이터 연구)

  • Kang, Gyeongji;Song, Kahye
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • Soft robot research has been actively conducted due to the advantages of soft materials that have less motion restrictions and higher energy efficiency compared to rigid robots. In particular, soft robots are being applied in more and more diverse fields, and the need for soft robots is increasing, especially when dealing with soft or deformable objects that rigid robots cannot perform. Various soft robots are being developed, and studies on artificial muscles with versatility, seamless integration with sensing, and self-healing capabilities are being proposed. In this study, we propose one of the most simple rectangular shaped HASEL (Hydraulically amplified self-healing electrostatic) actuators and compare the performance according to shape deformation such as the size or ratio of actuators and electrodes. Developing these actuators can be used in many ways for artificial muscles in soft robotics.

Control of The Soft Starter using Bluetooth (Bluetooth를 이용한 Soft Starter 제어)

  • Bae, Jong-Il;Hwang, Yeong-Yeun;Lee, Dong-Cheol;Bae, Cheol-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2735-2737
    • /
    • 2005
  • Been using widely Soft Starter control system is $Y-{\Delta}$ method, Reactor method, Resistor method etc. and this methods are big mobile warfare kind and voltage drop and can not operate because suspending load because smallest operation acceleration Torque is small.

  • PDF

Soft-Switching T-Type Multilevel Inverter

  • Chen, Tianyu;Narimani, Mehdi
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1182-1192
    • /
    • 2019
  • In order to improve the conversion efficiency and mitigate the EMI problem of conventional hard-switching inverters, a new soft-switching DC-AC inverter with a compact structure and a low modulation complexity is proposed in this paper. In the proposed structure, resonant inductors are connected in series for the arm branches, and resonant capacitors are connected in parallel for the neutral point branches. With the help of resonant components, the proposed structure achieves zero-current switching on the arm branches and zero-voltage switching on the neutral point branches. When compared with state-of-art soft-switching topologies, the proposed topology does not need auxiliary switches. Moreover, the commutation algorithm to realize soft-switching can be easily implemented. In this paper, the principle of the resonant operation of the proposed soft-switching converter is presented and its performance is verified through simulation studies. The feasibility of the proposed inverter is evaluated experimentally with a 2.4-kW prototype.