• Title/Summary/Keyword: Soft Surface

Search Result 975, Processing Time 0.034 seconds

Secondary closure of an extraction socket using the double-membrane guided bone regeneration technique with immediate implant placement

  • Yun, Jeong-Ho;Jun, Choong-Man;Oh, Nam-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.253-258
    • /
    • 2011
  • Purpose: Immediate implantation presents challenges regarding site healing, osseointegration, and obtaining complete soft-tissue coverage of the extraction socket, especially in the posterior area. This last issue is addressed herein using the double-membrane (collagen membrane+high-density polytetrafluoroethylene [dPTFE] membrane) technique in two clinical cases of posterior immediate implant placement. Methods: An implant was placed immediately after atraumatically extracting the maxillary posterior tooth. The gap between the coronal portion of the fixture and the adjacent bony walls was filled with allograft material. In addition, a collagen membrane (lower) and dPTFE membrane (upper) were placed in a layer-by-layer manner to enable the closure of the extraction socket without a primary flap closure, thus facilitating the preservation of keratinized mucosa. The upper dPTFE membrane was left exposed for 4 weeks, after which the membrane was gently removed using forceps without flap elevation. Results: There was considerable plaque deposition on the outer surface of the dPTFE membrane but not on the inner surface. Moreover, scanning electron microscopy of the removed membrane revealed only a small amount of bacteria on the inner surface of the membrane. The peri-implant tissue was favorable both clinically and radiographically after a conventional dental-implant healing period. Conclusions: Secondary closure of the extraction socket and immediate guided bone regeneration using the double-membrane technique may produce a good clinical outcome after immediate placement of a dental implant in the posterior area.

Model Based Investigation of Surface Area Effect on the Voltage Generation Characteristics of Ionic Polymer Metal Composite Film (모델 기반의 이온 전도성 고분자 필름 금속 복합체의 표면적 증가에 따른 전압생성 특성 변화에 관한 연구)

  • Park, Kiwon;Kim, Dong Hyun
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.401-407
    • /
    • 2016
  • IPMC is composed of thin ion conductive polymer film sandwiched between metallic electrodes plated on both surfaces. Ionic Polymer-Metal Composite (IPMC) generates voltages when bent by mechanical stimuli. IPMC has a potential for the variety of energy harvesting applications due to its soft and hydrophilic characteristics. However, the large-scale implementation is necessary to increase the output power. In this paper, the scale-up of surface area effect on voltage generation characteristics of IPMC was investigated using IPMC samples with different surface areas. Also, a circuit model simulating both the output voltage and its offset variations was designed for estimating the voltages from IPMC samples. The proposed model simulated the output voltages with offsets well corresponding to various frequencies of input bending motion. However, some samples showed that the increase of error between real and simulated voltages with time due to the nonlinear characteristic of offset variations.

New Measurement Method of Wound Healing by Stereoimage Optical Topometer System (Stereoimage Optical Topometer System을 이용한 새로운 창상 계측 방법)

  • Rho, Kyoung-Hwan;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.755-758
    • /
    • 2008
  • Purpose: In order to determine the amount of wound healing, objective sequential assessments of changes in wound size and depth are essential. Although a variety of measurements for wound healing have been proposed, a gold standard for quantifying day-to-day changes in healing has not been established. We present here a simple and non-invasive wound measurement method that quantitatively and accurately documents changes of the size of a raw surface and the volume of a soft tissue defect using a stereoimage optical topometer(SOT) system. Methods: Using a 5mm diameter biopsy punch, four circular wounds were created on abdominal area of a diabetic mouse. Photographs were taken using SOT system at baseline, 5th day and 10th postoperative day. The wound margin was traced on a digitalized photo and evaluated the area and the volume of the wound by SOT system. Results: The SOT system calculated a mean wound surface of $15.93{\pm}0.29mm^2$ and volume of $827.50{\pm}88.86$ intensity/pixel${\times}$area(I/PA) immediately after wounding. On the 5th day after the operation wound surface declined by $10.73mm^2$ and on the 10th day declined by $5.95mm^2$. The wound volume also declined from 827.50 I/PA to 161.75 I/PA and 30.50 I/PA on 0, 5th and 10th day, respectively. Conclusion: The SOT system described in this study represents a reliable, simple, practical, and non-invasive technique to accurately monitor and evaluate wound healing.

A Study on Softening Finish of Cotton Fabric using Cellulase (셀루라아제에 의한 면직물의 유연가공에 관한 연구)

  • Kang Ji-Yun;Ryu Hyo-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.4 s.36
    • /
    • pp.262-273
    • /
    • 1990
  • The purpose of this study is to investigate the softening effect of cellulase-treated cotton fabric and the damage on the fabric which is accompanied by the treatemnt. Cotton fabric is treated with cellulase under various concentrations and time, and the weight loss, hand values (by KES), surface characteristics, moisture regain, tensile strength, copper number and intrinsic viscosity of the treated samples and untreated samples have been compared. The results are as follows: 1. The weight loss of cotton fabric increased as the concentration of cellulase and the treating time increased. 2. The enzyme treatment had little effect on the stiffness of the treated samples but anti- drape stiffness decreased for the treated samples. Fullness and softness of the treated samples increased and crispness decreased with the lowest level reaching after two hours of the treatment for all concentrations. Scrooping feeling of the treated samples increased and flexibility with soft feeling increased as the treating time and the concentration of cellulase increased. 3. Moisture regain of the samples decreased as the treating time and the concentration of the enzyme increased and the treated fabric showed cracks on the fiber surface, and much surface fibers on the fabric have been removed after the treatment. 4. Tensile strength of the samples decreased as the treating time and as the concentration of cellulase increased, and the copper number increased while the intrinsic viscosity decreased as the treating time increased, but cellulase concentration had a little effect.

  • PDF

Rainfall Harvesting as an Alternative Water Supply in Water Stressed Communities in Aguata-Awka Area of Southeastern Nigeria

  • Okpoko, Ephraim;Egboka, Boniface;Anike, Luke;Okoro, Elizabeth
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.95-101
    • /
    • 2013
  • Alternative sources of water are sought in some water stressed communities in the study area. The study focuses on the Aguata-Awka area of southeastern Nigeria. Aquifers occur at great depths, and surface waters may be far from homesteads. The scarcity of water has necessitated the people to adopt various local technologies for harvesting rainfall. The local technology includes collecting rainwater from roofs and channeling the water into large underground tanks, shallow wells and surface reservoirs. Large concrete tanks of $6m{\times}6m{\times}4m$ dimensions are often built underground and can store $144m^3$ of water. Surface reservoirs built on 4 m concrete pillar supports having dimensions of $10m{\times}10m{\times}4m$ and have a storage capacity of $400m^3$. Water samples were collected at 3 different locations of Agulu, Ekwulobia, and Awka and were analyzed for their physical, chemical, and bacteriological parameters. Results indicate a range of values for pH, 5.9 to 7.1; turbidity, 0.9 to 2.7; total dissolved solids, 80 to 170 mg/L; total hardness, 4.5 to 6.4 mg/L; magnesium, 1.2 to 1.4 mg/L; bicarbonate, 19.4 to 83.6 mg/L; and sulfate, 3.6 to 6.4 mg/L. Bacteriological analysis results were negative for fecal and total coliform counts. All parameters, with the exception of pH where aluminum and galvanized iron roofs are used for collection, fall within the recommended guidelines for drinking water quality of the World Health Organization, and the Standard Organization of Nigeria, new Nigerian standards for drinking water quality. Magnesium is above the maximum permitted level for consumer acceptability of the Nigerian standards for drinking water quality. The water can be classified as fresh moderately hard and soft. The water can be described as a calcium and bicarbonate type.

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

Influence of Lithiation on Nanomechanical Properties of Silicon Nanowires Probed with Atomic Force Microscopy

  • Lee, Hyun-Soo;Shin, Weon-Ho;Kwon, Sang-Ku;Choi, Jang-Wook;Park, Jeong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.110-110
    • /
    • 2011
  • The nanomechanical properties of fully lithiated and unlithiated silicon nanowire deposited on silicon substrate have been studied with atomic force microscopy. Silicon nanowires were synthesized using the vapor-liquid-solid process on stainless steel substrates using Au catalyst. Fully lithiated silicon nanowires were obtained by using the electrochemical method, followed by drop-casting on the silicon substrate. The roughness, derived from a line profile of the surface measured in contact mode atomic force microscopy, has a smaller value for lithiated silicon nanowire and a higher value for unlithiated silicon nanowire. Force spectroscopy was utilitzed to study the influence of lithiation on the tip-surface adhesion force. Lithiated silicon nanowire revealed a smaller value than that of the Si nanowire substrate by a factor of two, while the adhesion force of the silicon nanowire is similar to that of the silicon substrate. The Young's modulus obtained from the force-distance curve, also shows that the unlithiated silicon nanowire has a relatively higher value than lithiated silicon nanowire due to the elastically soft amorphous structures. The frictional forces acting on the tip sliding on the surface of lithiated and unlithiated silicon nanowire were obtained within the range of 0.5-4.0 Hz and 0.01-200 nN for velocity and load dependency, respectively. We explain the trend of adhesion and modulus in light of the materials properties of silicon and lithiated silicon. The results suggest a useful method for chemical identification of the lithiated region during the charging and discharging process.

  • PDF

A study on point-location by finger-sensation -within the context of ${\ulcorner}Zhenjiudacheng{\lrcorner}$- (절순문안과 취혈의 관계에 대한 고찰 -"침구대성"을 중심으로-)

  • Lee, Joon-Moo;Kim, Taek-Ryul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.4
    • /
    • pp.175-185
    • /
    • 2005
  • Objective : The skill of locating acupoints accurately is an essential part of acupuncture treatment. Bone-scale has been used as a basic coordinates to locate acupoints and has been considered as an important factor of locating acupoints. This study was designed to stress the impotance of QieXunMenAn, which means pressing and rubbing softly the surface around the part pointed with proportional method, in locating acupoints. Methods and results : All expressions related with QieXunMenAn, among the descriptions of acupoint locations in ${\ulcorner}Zhenjiudacheng{\lrcorner}$, were investigated. The activity of QieXunMenAn has been regarded as an important method of locating acupoints since Neijing. QieXunMenAn means pressing and rubbing softly the surface around the part pointed with proportional method. It is a process of locating acupoint in detail by finger-sensation after locating the point with proportional method. Xianzhang, Dongmaiyingshou, and Wanwanzhong have been used to describe how to locate acupuncture-point through QieXunMenAn procedure. Xianzhong means a small depression or a pit on the surface of the body. Wanwanzhong describes that it feels very soft and tender. Descriptions related with QieXunMenAn procedures were found in around 87% of acupoint locations, thus stressing out its procedure. Conclusions : Bone-scale and QieXunMenAn do not mean different methods but the procedures that should be both performed every time when we locate most of the acupoints. Until recently, QieXunMenAn has been paid less attention that it should be. OieXunMenAn as well as bone-scale may be necessary to help locate acupoints accurately.

  • PDF

Bacterial adhesion and colonization differences between zirconia and titanium implant abutments: an in vivo human study

  • De Oliveira, Greison Rabelo;Pozzer, Leandro;Cavalieri-Pereira, Lucas;De Moraes, Paulo Hemerson;Olate, Sergio;De Albergaria Barbosa, Jose Ricardo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.217-223
    • /
    • 2012
  • Purpose: Several parameters have been described for determining the success or failure of dental implants. The surface properties of transgingival implant components have had a great impact on the long-term success of dental implants. The purpose of this study was to compare the tendency of two periodontal pathogens to adhere to and colonize zirconia abutments and titanium alloys both in hard surfaces and soft tissues. Methods: Twelve patients participated in this study. Three months after implant placement, the abutments were connected. Five weeks following the abutment connections, the abutments were removed, probing depth measurements were recorded, and gingival biopsies were performed. The abutments and gingival biopsies taken from the buccal gingiva were analyzed using real-time polymerase chain reaction to compare the DNA copy numbers of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and total bacteria. The surface free energy of the abutments was calculated using the sessile water drop method before replacement. Data analyses used the Mann Whitney U-test, and P-values below 0.05 find statistical significance. Results: The present study showed no statistically significant differences between the DNA copy numbers of A. actinomycetemcomitans, P. gingivalis, and total bacteria for both the titanium and zirconia abutments and the biopsies taken from their buccal gingiva. The differences between the free surface energy of the abutments had no influence on the microbiological findings. Conclusions: Zirconia surfaces have comparable properties to titanium alloy surfaces and may be suitable and safe materials for the long-term success of dental implants.

Deterioration Diagnosis and Conservation Treatment of the Three-storied Stone Pagoda in Seungansaji Temple Site, Hamyang, Korea (함양 승안사지 삼층석탑의 풍화훼손도 진단과 보존처리)

  • Lee, Myeong Seong;Choi, Hee Su;Kim, Ji Young;Lee, Chan Hee;Kim, Sun Duk
    • 보존과학연구
    • /
    • s.32
    • /
    • pp.99-112
    • /
    • 2011
  • The three-storied stone pagoda located in Seungansaji temple site consists mainly of medium to fine-grained biotite granite and granitic gneiss, and partly macrocrystalline gneiss, muscovite gneiss and gabbro. The surface of the stone pagoda is extensively colonized by lichen and moss due to surrounding trees and lawns, and severly deteriorated. Therefore, a comprehensive deterioration diagnosis has been carried out and conservation treatment was conducted in this study. For the conservation treatment, dry cleaning is performed throughout all the surface of the pagoda for naturally grown lichen and biological contaminants using a soft brush and wooden knife. Crustose lichen strongly adhere to the surface was removed by wet cleaning using distilled water. Also, protective railings were reinstalled to an appropriate height with taking the distance from the stone pagoda into account. Finally, the ground around the stone pagoda was repaired with clay sand, and dike was installed with a natural gradient to facilitate water drainage.

  • PDF