• 제목/요약/키워드: Soft Surface

검색결과 975건 처리시간 0.028초

Study on the Parameter Optimization of Soft-switching DC/DC Converters with the Response Surface Methodology, a SPICE Model, and a Genetic Algorithm

  • Liu, Shuai;Wei, Li;Zhang, Yicheng;Yao, Yongtao
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.479-486
    • /
    • 2015
  • The application of soft-switching techniques is increasing in the DC/DC converter area. It is important to design soft-switching parameters to ensure the converter operates properly and efficiently. An optimized design method is presented in this paper. The objective function is the total power loss of a converter, while the variables are soft-switching parameters and the constraints are the electrical requirements for soft-switching. Firstly, a response surface methodology (RSM) model with a high precision is built, and the rough optimized parameters can be obtained with the help of a genetic algorithm (GA) in the solution space determined by the constraints. Secondly, a re-optimization is conducted with a SPICE model and a GA, and accurate optimized parameters can be obtained. Simulation and experiment results show that the proposed method performs well in terms of a wide adaptability, efficiency, and global optimization.

Soft-tissue thickness of South Korean adults with normal facial profiles

  • Cha, Kyung-Suk
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.178-185
    • /
    • 2013
  • Objective: To standardize the facial soft-tissue characteristics of South Korean adults according to gender by measuring the soft-tissue thickness of young men and women with normal facial profiles by using three-dimensional (3D) reconstructed models. Methods: Computed tomographic images of 22 men aged 20 - 27 years and 18 women aged 20 - 26 years with normal facial profiles were obtained. The hard and soft tissues were three-dimensionally reconstructed by using Mimics software. The soft-tissue thickness was measured from the underlying bony surface at bilateral (frontal eminence, supraorbital, suborbital, inferior malar, lateral orbit, zygomatic arch, supraglenoid, gonion, supraM2, occlusal line, and subM2) and midline (supraglabella, glabella, nasion, rhinion, mid-philtrum, supradentale, infradentale, supramentale, mental eminence, and menton) landmarks. Results: The men showed significantly thicker soft tissue at the supraglabella, nasion, rhinion, mid-philtrum, supradentale, and supraglenoid points. In the women, the soft tissue was significantly thicker at the lateral orbit, inferior malar, and gonion points. Conclusions: The soft-tissue thickness in different facial areas varies according to gender. Orthodontists should use a different therapeutic approach for each gender.

Front-to-Back Ratio Improvement of a Microstrip Patch Antenna Loaded with Soft Surface Structure in a Partially Removed Ground Plane

  • Lee, Hong-Min
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.247-253
    • /
    • 2012
  • This study presents a new, simple method for improving the front-to-back (F/B) ratio of a microstrip patch antenna. The back radiation of the microstrip patch antenna is reduced by removing some metallic parts around the ground plane and placing a new soft-surface configuration, consisting of an array of stand-up split-ring resonators on a bare dielectric substrate near the two ground plane edges. Compared to the F/B ratio of a conventional microstrip patch antenna with a full ground plane of the same size, our proposed microstrip patch antenna experimentally achieves an improved F/B ratio of 9.6 dB.

Soft-Lithographic Fabrication of Ni Nanodots Using Self-Assembled Surface Micelles

  • Seo, Young-Soo;Lee, Jung-Soo;Lee, Kyung-Il;Kim, Tae-Wan
    • Journal of Magnetics
    • /
    • 제13권2호
    • /
    • pp.53-56
    • /
    • 2008
  • This study proposes a simple nano-patterning process for the fabrication of magnetic nanodot arrays on a large area substrate. Ni nanodots were fabricated on a large area (4 inches in diameter) Si substrate using the soft lithographic technique using self-assembled surface micelles of Polystyrene-block-Poly(methyl methacrylate) (PS-b-PMMA) diblock copolymer formed at the air/water interface as a mask. The hexagonal array of micelles was successfully transferred to a Ni thin film on a Si substrate using the Langmuir-Blodgett technique. After ion-mill dry etching, a magnetic Ni nanodot array with a regular hexagon array structure was obtained. The Ni nanodot array showed in-plane easy axis magnetization and typical soft magnetic properties.

점성토 준설매립지반의 자중압밀과 대기건조 영역분리에 의한 표층고결 촉진공법 (Quick Surface Strengthening of Soft Dredged Clay Fill by Dividing the Layer into Self Consolidation and Desiccation)

  • 김현태;김승욱;김상규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.499-506
    • /
    • 2004
  • The use of dredged soft marine clay is increasing due to a shortage of coarse material available. This paper presents a stabilization method that can increase shear strength of the surface layer of a dredged clay deposit at dates much earlier than usual. The desiccation of the upper soft 1-2m layer can be accelerated by interrupting water seeping from its bottom with impervious geotextile. Just below the geotextile, enough pervious material is provided so that the underlying deposit can be drained through it. This scheme is proved to be effective through theoretical analysis.

  • PDF

고속회전 하는 정밀부품을 위한 연질/경질 코팅의 트라이볼로지적 특성에 관한 연구 (Tribological Characteristics of Soft/Hard Coating for High-Speed Rotating Machine Elements)

  • 오진규;정구현;김대은;유제환;김형채
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.393-397
    • /
    • 2003
  • Recently, rotating elements which use mechanical and electrical systems have been utilized for high speed and accuracy to increase the performance. The most important thing to get a more reliable system is to understand the friction, wear and characteristics which has an effect on various coated surfaces. In this study, the tribologicali characteristics of various soft/hard materials were investigated by using a custom-built pin-on-reciprocator tester From the experimental results, it was found that the friction coefficients of the soft material coated surfaces were lower under various normal loads due to trier self-lubricating ability and material transfer to the counter surface.

  • PDF

레이저 처리후 임프란트 표면 변화에 관한 연구 (The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive)

  • 김태정;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Toughness of soft-hard composites and Wetting on Textured Substrates

  • Okumura, Ko
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.4.1-4.1
    • /
    • 2010
  • In the first part, after discussing works on nacre, a soft-hard composite found in nature, including a simulation on network mimicking nacre [1-4], we talk on a simple model of spider webs, another example of natural soft-hard structure [5]. We demonstrate that the web network is free of stress concentrations because the radial threads are stronger than the spiral threads. In the second part, after reviewing our works on wetting on textured surfaces [6-8], we discuss penetration into textured surface and instability of a liquid film on textured substrates during spin coating [9,10].

  • PDF

수종의 레이저로 임프란트 표면 처리 시 표면 형태의 변화에 대한 주사전자 및 주사탐침 현미경적 연구 (The SEM and SPM Study on the Change of Machined Titanium Implant Surface following Various Laser Treatments)

  • 김인경;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.451-463
    • /
    • 2001
  • Following the extensive use of implant, the incidence of peri-implantitis increases. Guided bone regeneration has been used for the optimal treatment of this disease. Because implant surface was contaminated with plaque and calculus, cleaning and detoxification were needed for the reosseointegration when guided bone regeneration was performed. Various mechanical and chemical methods have been used for cleaning and detoxification of implant surface, air-powder abrasive and oversaturated citrate were known to be most effective among these methods. However, these methods were incomplete because these could not thoroughly remove bacteria of implant surface, moreover deformed implant surface. Recent studies for detoxification of the implant surface using laser were going on, $CO_2$ laser and Soft Diode laser were known to be effective among these methods. The purpose of this study was to obtain clinical guide by application these laser to implant surface. 15 experimental machined pure titanium cylinder models were fabricated. The $CO_2$ laser treatment under dry, wet and hydrogen peroxide condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of models. Each groups were examined with SPM and SEM to know whether their surface was changed. The results were as follows : 1. Surface roughness and surface form weren't changed when $CO_2$ laser was usedunder dry condition(P>0.05). 2. Surface roughness and surface form weren't changed when $CO_2$ laser was used under wet condition(P>0.05). 3. Surface roughness and surface form weren't changed when $CO_2$ laser was used under hydrogen peroxide condition(P>0.05). 4. Surface roughness and surface form weren't changed when Soft Diode laser was used under toluidine blue O solution condition(P>0.05). From the result of this study, it may be concluded that the $CO_2$ laser having relatively safe pulse mode and the Soft Diode laser used with photosensitizer can be used safely to treat peri-implantitis.

  • PDF

임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰 (A literature review on implant abutment and soft tissue response)

  • 이영훈;고경호;허윤혁;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.263-273
    • /
    • 2016
  • 지대주의 재료와 표면에 따라 연조직반응이 다르고 임플란트 주위염의 원인이 될 수 있다. 티타늄과 지르코니아는 우수한 생체적합성을 가져 안정적인 연조직반응을 보이고 금합금은 표면상태에 따라 연조직반응이 다르게 나타난다. 같은 재료라도 표면특성에 따라 연조직반응이 영향을 받는다. 표면거칠기 증가는 박테리아 부착을 유발하므로 연조직과 접촉하는 부분은 평활한 표면을 가져야 한다. 추가적인 표면처리를 통해 박테리아의 부착은 증가시키지 않으면서 세포반응을 촉진시킬 수 있다. 지대주의 형태 및 반복착탈도 연조직반응에 영향을 줄 수 있다. 초음파 세척과 아르곤 플라즈마 처리는 비교적 효과적으로 맞춤형 지대주의 잔류 미세입자를 제거할 수 있는 방법이다.