• Title/Summary/Keyword: Soft Appliance

Search Result 63, Processing Time 0.027 seconds

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Changes of the Pharyngeal Space by Various Oral Appliances for Snoring (수종의 코골이장치 장착에 따른 인두공간의 변화)

  • Jo, Chul-Bae;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.247-256
    • /
    • 2009
  • The purpose of this study was to investigate the changes of the pharyngeal space when the following appliances were inserted: the mandibular advancement appliance (MAA), tongue retaining appliance (TRA), and mandibular advancement-tongue retaining appliance (MATRA). Nine male dental students exhibiting Class I occlusion, normal body mass index (BMI), and no signs and symptoms of snoring were selected for this study. The three kinds of snoring appliances (MAA, TRA and MATRA) were fabricated for each subject. The mandibular advancement of the MAA and MATRA was set at a distance of 5 mm, and the TRA and MATRA were made to hold the tongue in front of the maxillary incisors by 10 to 20 mm. Lateral cephalometric radiographs of the following four states - with no appliance, MAA, TRA, and MATRA - were taken to examine any anatomical changes resulting from the application of the appliances. All four radiographs were traced and analyzed for twenty selected variables related to the pharyngeal space, cranio-cervical posture, and position of the soft palate and hyoid bone. According to the results of this study, there were significant increases in both the upper and lower oropharyngeal spaces when the mandible and tongue were protruded simultaneously, although there was a significant increase only in upper oropharyngeal space when the mandible or tongue was advanced separately. In conclusion, it is suggested that the MATRA may result in more positive effect on the control of snoring and OSA compared to a single use of the MAA or TRA, especially for the patients whose upper airway obstruction occurs in the lower oropharynx.

A STUDY ON THE EFFECT OF TREATMENT IN THE SKELETAL CLASS III MALOCCLUSION PATIENT WITH ANTERIOR CROSSBITE (전치부 반대 교합을 동반한 골격성 3급 부정교합 환자의 치료에 관한 연구)

  • Moon, Yoon-Shik
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.475-483
    • /
    • 1993
  • The purpose of this study was to investigate the treatment effects on anterior crossbite patients using chin cap and labiolingual arch appliance. In the present study, I statistically evaluated measurement values on a cephalogram before and after treatment form twenty anterior crossbite cases. The results were as follows: 1. In the craniofacial patterns, cranial base increased after treatment. 2. In the maxillo-mandibular relationship, ANB and Facial convexity significantly increased. 3. In the denture patterns, occlusal plane, Ul to FH and Overjet significantly increased. On the contrary overbite decreased significantly. Lower incisors inclined lingually. 4. In the soft tissue profile changes, lower lip protrusion was signifacantly improved.

  • PDF

Development of Induction Heated Hot Water Producer using Soft Switching PWM High Frequency Inverter

  • Fujita Kentarou;Moisseev Serguei;Gaimage Laknath;Chandhaket Sarawouth;Muraoka Hidekazu;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.491-494
    • /
    • 2003
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or Dual Packs Heater in hot water producer, boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, all active clamped edge resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle oi zero voltage soft communication with PWM is developed and demonstrated for a high efficient Induction heated hot water producer and boiler in the consumer power applications. This consumer induction heater power appliance using active clamp soft switching PWM high frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Development of Induction Heater Hot Water System using New Active Clamping Quasi Resonant ZVS PWM Inverter

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.23-29
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current based stainless steel plate spiral type heater for heat exchanger or dual packs heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamping quasi-resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated for a high efficient induction heated hot water system and boiler in the consumer power applications. This consumer induction heater power appliance using active clamping soft switching PWM high frequency inverter is evaluated and discussed on the basis of experimental results.

The Effect of Speech Aids in Velopharyngeal Incompetency Patients (비인강 폐쇄부전 환자에서 발음보조장치의 치료효과)

  • Ko, S.O.;Shin, H.K.;Kim, H.G.;Hong, K.H.;Seo, J.H.;Ko, D.H.
    • Speech Sciences
    • /
    • v.3
    • /
    • pp.57-69
    • /
    • 1998
  • Velopharyngeal function refers to the combined activity of the soft palate and pharynx in closing and opening the velopharyngeal port to the required degree. In normal speech, during the production of oral consonant sounds elevation of the soft palate, along with the superior constrictor muscle, occludes the oropharynx from the nasopharynx. Inadequate velopharyngeal function caused by congenital or acquired insufficiency or incompetency may result in abnormal speech characterized by hypernasality, nasal emission and decreased intelligibility of speech due to weak consonant production. The speech aid is often helpful in improving the speech of individuals with velopharyngeal incompetency. In this article, the pathogenesis and treatment of velopharyngeal incompetence are discussed and a speech aid appliance that was constructed for the patient is described.

  • PDF

Correction of late adolescent skeletal Class III using the Alt-RAMEC protocol and skeletal anchorage

  • Muhammed Hilmi Buyukcavus;Omer Faruk Sari;Yavuz Findik
    • The korean journal of orthodontics
    • /
    • v.53 no.1
    • /
    • pp.54-64
    • /
    • 2023
  • This case report describes skeletal anchorage-supported maxillary protraction performed with the Alternate Rapid Maxillary Expansion and Constriction (AltRAMEC) protocol over a treatment duration of 14 months in a 16-year-old female patient who was in the late growth-development period. Miniplates were applied to the patient's aperture piriformis area to apply force from the protraction appliance. After 9 weeks of following the Alt-RAMEC protocol, miniplates were used to transfer a unilateral 500-g protraction force to a Petit-type face mask. A significant improvement was observed in the soft tissue profile in measurements made both cephalometrically and in three dimensional photographs. Subsequently, the second phase of fixed orthodontic treatment was started and the treatment was completed with the retention phase. Following treatment completion, occlusion, smile esthetics, and soft tissue profile improved significantly in response to orthopedic and orthodontic treatment.

Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter (듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기)

  • Lee, Sang-Wook;Ryu, Yeoi-Joung;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

Orthopedic and Orthodontic Treatments of a Patient with Parry-Romberg Syndrome (Parry-Romberg Syndrome 환자에서 악정형 및 교정 치료)

  • You, Kug-Ho;Baik, Hyoung-Seon
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Parry-Romberg syndrome(PRS) is a degenerative disease characterized by progressive hemifacial atrophy. A 10-year-old girl who had been treated for linear scleroderma at the dermatologic department visited the orthodontic department. The frontal facial photograph showed mild facial asymmetry. On the left side, mild atrophy of soft tissue, enophthalmos, cheek depression, and dry skin with dark pigmentation were observed. The radiograph showed the hypoplasia of both the maxilla and mandible on the left side. This case report describes the treatment of a patient with PRS for 7 years. To minimize the effect of progressive atrophy on the facial growth, a hybrid appliance was used. The facial photos and radiographic records were periodically taken to analyze the progression of PRS. Although it is impossible to prevent the progression of facial asymmetry, it appears to be possible to limit the atrophic effect. After the stabilization of PRS, the orthodontic treatment by the fixed appliance was performed. Additionally, autologous fat graft was performed three times at 6 month intervals. After the treatment, the patient had a confident smile and facial asymmetry was improved.

  • PDF