• 제목/요약/키워드: Sodium-water

검색결과 2,042건 처리시간 0.036초

Poly(sodium acrylate-co-acrylamide-co-2-hydroxyethyl acrylate)의 제조와 고흡수 특성 (Preparation and Super-Water-Absorbency of Poly(sodium acrylate-co-acrylamide-co-2-hydroxyethyl acrylate))

  • Zhang Yuhong;Deng Min;He Peixin
    • 폴리머
    • /
    • 제30권4호
    • /
    • pp.286-292
    • /
    • 2006
  • Super water-absorbent resins were prepared by inverse suspension copolymerization of sodium acrylate, acrylamide and 2-hydroxyethyl acrylate using N, N'-methylene-bis-acrylamide as cross-linker. For the suspension copolymerization, monohexadecyl phosphate was employed as the dispersing agent, cyclohexane as the dispersing medium and potassium persulfate as the initiator. The dependence of water-absorption capacity on the amount of crosslinking agent, oil/water ratio, degree of neutralization and the composition of the copolymer were systematically investigated. Furthermore, the swelling kinetics of the super water-absorbent copolymer was carried out. The absorption of the resins is more than 1800 g/g for deionized water and 100 g/g for 0.9% NaCl solution, respectively. The copolymers showed an increased salt resistance and enhanced water retention of soil.

간척지토양의 제염용수량산정에 관한 실험연구 (A Laboratory Study on the Estimation of Water Requirements for the Desalinization of Reclaimed Tidelands)

  • 구자웅;한강원;은종호
    • 한국농공학회지
    • /
    • 제31권1호
    • /
    • pp.96-105
    • /
    • 1989
  • This laboratory study was performed to produce basic data for the estimation of water requirements for desalinization, through analyzing changes of the electrical conductivity and the exchangeable sodium percentage during the desalinization of reclaimed tidelands. Desalinization experiments were carried out by two water management practices, namely, the leaching method by subsurface drainage and the rinsing method by surface drainage, using samples of silt loam soil and silty clay loam soil collected in reclaimed tidelands. The results obtained from this study were summarized as follows : 1. The sample soils used in this study were saline-sodic soils with the high electrical conductivity and the high exchangeable sodium percentage. 2. Changes of the electrical conductivity and the exchangeable sodium percentage with water requirements for desalinization showed a similar tendency in the desalinization experiment by the same water management practice. 3. The regression equation between the relative electrical conductivity(EC/EC) and water requirements for desalinization(Dw/Ds) could be described by Dw/Ds=O. 29x(EC/EC.) -0.982 (Leaching method), Dw/Ds=3. 678X0. 030(EC/EC ) (Rinsing method). 4. The regression equation between the relative exchangeable sodium percentage (ESP/ESP ) and water requirements for desalinization (Dw/Ds) could be expressed in Dw/Ds = 0.039 x (ESP/ESP. ) - 1. 134 (Leaching method), Dw/Ds=7. 197X0. 024(ESP/ESP ) (Rinsing method). 5. It was estimated that water requirements for the adequate desalinization would be Dw/Ds=0.3 (Leaching method) and Dw/Ds=3.0 (Rinsing method)

  • PDF

Experimental Approach on Sulfate Attack Mechanism of Ordinary Portland Cement Matrix: Part I. Sodium Sulfate Attack

  • 문한영;이승태;김종필
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.557-564
    • /
    • 2004
  • This paper introduces a study carried out to investigate sodium sulfate attack caused by various reactive products. Experiments were performed on mortar and paste specimens made with ordinary Portland cement (OPC) conforming to KS L 5201 Type I. The water-cement ratios were varied from 0.35 to 0.55. It was found from the laboratory study that the water-cement ratio may be a key to control the deterioration of OPC matrix during sodium sulfate attack. Furthermore, X-ray diffraction (XRD) confirmed that ettringite, gypsum and thaumasite were the main products formed by sodium sulfate attack. These findings were well supported by thermal analysis through differential scanning calorimetry (DSC), and confirmed the long-term understanding that deterioration mechanism by sodium sulfate attack is a complicated process. Most importantly, deterioration due to sodium sulfate attack is characterized as the drastic reduction in compressive strength as well as the expansion (especially in cement matrix with a higher water-cement ratio).

Sucrose-NaCl- 물의 3성분 혼합액체의 점도에 관한 연구 (Viscosities of Ternary Mixtures of Sucrose-Sodium Chloride-Water)

  • 오명숙
    • 한국식품과학회지
    • /
    • 제22권1호
    • /
    • pp.66-70
    • /
    • 1990
  • sucrose-Nacl-물의 3성분 혼합액체의 점도를 예측하기 위한 모델을 결정하기 위하여 온도 $10{\sim}40^{\circ}C$, NaCl농도 $1.0064{\sim}5.7037mol$, sucrose농도 $0.3436{\sim}2.5966mol$의 범위에서 점도 실험을 행한 결과 다음의 결과를 얻었다. NaCl용액의 점도는 식 (8)로, sucrose용액의 점도는 식 (5)로 나타낼 수 있었다. 또한 식 (8)과 (5)의 계수들은 강한 온도의존성을 가지고 있었고 식 (7)로 표현되었다. NaCl-sucrose-물의 3성분 혼합액체의 점도는 5개의 계수를 가진 다항식인 식 (9)로 상당히 정확하게 표현할 수 있었고, NaCl용액과 sucrose용액 사이에는 상호작용은 거의 없는 것으로 생각되었다.

  • PDF

측뇌실내로 투여한 Thiopental Sodium의 가토 신장기능에 미치는 영향 (Influence of Intracerebroventricular Thiopental Sodium on the Renal Function in Conscious Rabbit)

  • 홍기방;조경우
    • The Korean Journal of Physiology
    • /
    • 제19권1호
    • /
    • pp.35-48
    • /
    • 1985
  • One of most frequently used anesthetic agents is barbiturate derivatives. Pentobarbital or thiopental sodium have been used most frequently in the laboratory or clinical practice. There have been reports on the renal effects of barbiturate anesthesia in human and laboartory animals. Renal effects of thiopental sodium anesthesia, however, are still controversial. One of the discrepancies may be derived from the doses used. It has been reported that subanesthetic small dose of thiopental sodium influences the renal function directly. To clarify possible central effects of very small amounts of thiopental sodium on the renal function, experiments have been done in conscious rabbits. Thiopental sodium was infused into the lateral cerebroventricle for 10 minutes. Intracerebroventricular thiopental sodium induced increased urinary volume, glomerular filtration rate and renal plasma flow by doses of $0.1{\sim}1.0\;mg/10 min/rabbit$. Filtration fractions were not changed. Sodium, chloride and potassium excretions were increased by 0.065 mg/10 min/rabbit of thiopental sodium without significant changes of renal hemodynamics. Higher doses of thiopental sodium $(0.1{\sim}1.0\;mg/10 min/rabbit)$ induced greater increases of electrolytes excretion and renal hemodynamics. Free water clearance was not changed by thiopental sodium, but the fractional excretion of free water showed a tendency of decrease. Fractional excretion of sodium was increased by doses of 0.065 to 1.0 mg of thiopental sodium . Highly significant correlation between the changes of glomerular filtration rate and the changes of sodium excretion were found in the higher doses. Plasma renin concentration (activity) was not changed by the centrally administered thiopental sodium. Intravenous thiopental sodium, 1.0 mg/rabbit, induced no changes of renal function in conscious rabbit. These data suggest that intracerebroyentricular thiopental sodium can increase urinary sodium excretion directly by inhibition of sodium reabsorption in the renal tubules and/or indirectly by increasing the renal hemodynamics.

  • PDF

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

수분 대사 장애 질환의 병태 생리와 치료 (Pathophysiology and management of disorders in water metabolism)

  • 김동언
    • Clinical and Experimental Pediatrics
    • /
    • 제50권5호
    • /
    • pp.430-435
    • /
    • 2007
  • Even though we drink and excrete water without recognition, the amount and the composition of body fluid remain constant everyday. Maintenance of a normal osmolality is under the control of water balance which is regulated by vasopressin despite sodium concentration is the dominant determinant of plasma osmolality. The increased plasma osmolality (hypernatremia) can be normalized by the concentration of urine, which is the other way of gaining free water than drinking water, while the low plasma osmolality (hyponatremia) can be normalized by the dilution of urine which is the only regulated way of free water excretion. On the other hand, volume status depends on the control of sodium balance which is regulated mainly by renin-angiotensin-aldosterone system, through which volume depletion can be restored by enhancing sodium retention and concomitant water reabsorption. This review focuses on the urine concentration and dilution mechanism mediated by vasopressin and the associated disorders; diabetes insipidus and syndrome of inappropriate antidiuretic hormone secretion.

삼인산 나트륨과 아질산 나트륨에 의한 탄소강 부식방지 특성 연구 (Study on The Corrosion Inhibition Characteristics of Carbon Steel by Sodium Phosphate And Sodium Nitrite)

  • 문전수;이재근
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 2010
  • Sodium nitrite is widely used as one of the popular corrosion inhibitors for the protection of ferrous metal in closed cooling water system, such as a diesel engine and a chiller. The optimum treatment conditions are studied through laboratory tests using linear polarization resistance (LPR) technique. Corrosion rate of the carbon steel electrode could be maintained less than $2.5{\times}10^{-3}$ mmpy in the test condition of 500 ppm as ${NO_2}^-$, 200 ppm as $Cl^-$, $70^{\circ}C$ and pH 6.8. The pH control is confirmed not to be an important factor in the protection of carbon steel by sodium nitrite inhibitor. The addition of tolyltriazole was needed for the protection of the copper alloy in the sodium nitrite treatment system.

Sodium cloxacillin의 유기용매(有機溶媒)에 의한 결정화(結晶化) 및 안정성(安定性)에 관한 연구(硏究) (Studies on the Crystallization in Organic Solvents and the Stability of Sodium Cloxacillin)

  • 백우현;김정우;봉득환
    • 약학회지
    • /
    • 제22권1호
    • /
    • pp.8-14
    • /
    • 1978
  • The method that changes sodium cloxacillin from amorphous form to hydrate form was investigated. Using organic solvents of which dielectric constants are greater than 9, the amorphous sodium cloxacillin could be changed to hydrate form. The difference of water content of sodium cloxacillin hydrate caused the differences of ir spectrum at $3,350~3,360cm_{-1}$, and owing to the decrease of water content, hydrate form was changed to the morphous form, which could be identified by x-ray diffraction pattern. Regarding the stability of sodium cloxacillin in activity, the hydrate form was stable but the amorphous form was very unstable. Moreover, the stable hydrate form was scarcely hygroscopic, while the other form was hygroscopic, becoming a fused state ar $50^{\circ}$. and R.H. 50%.

  • PDF