• Title/Summary/Keyword: Smoothing region

Search Result 98, Processing Time 0.024 seconds

Stereo Matching For Satellite Images using The Classified Terrain Information (지형식별정보를 이용한 입체위성영상매칭)

  • Bang, Soo-Nam;Cho, Bong-Whan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.1 s.6
    • /
    • pp.93-102
    • /
    • 1996
  • For an atomatic generation of DEM(Digital Elevation Model) by computer, it is a time-consumed work to determine adquate matches from stereo images. Correlation and evenly distributed area-based method is generally used for matching operation. In this paper, we propose a new approach that computes matches efficiantly by changing the size of mask window and search area according to the given terrain information. For image segmentation, at first edge-preserving smoothing filter is used for preprocessing, and then region growing algorithm is applied for the filterd images. The segmented regions are classifed into mountain, plain and water area by using MRF(Markov Random Filed) model. Maching is composed of predicting parallex and fine matching. Predicted parallex determines the location of search area in fine matching stage. The size of search area and mask window is determined by terrain information for each pixel. The execution time of matching is reduced by lessening the size of search area in the case of plain and water. For the experiments, four images which are covered $10km{\times}10km(1024{\times}1024\;pixel)$ of Taejeon-Kumsan in each are studied. The result of this study shows that the computing time of the proposed method using terrain information for matching operation can be reduced from 25% to 35%.

  • PDF

Determination of Nitrogen in Fresh and Dry Leaf of Apple by Near Infrared Technology (근적외 분석법을 응용한 사과의 생잎과 건조잎의 질소분석)

  • Zhang, Guang-Cai;Seo, Sang-Hyun;Kang, Yeon-Bok;Han, Xiao-Ri;Park, Woo-Churl
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.259-265
    • /
    • 2004
  • A quicker method was developed for foliar analysis in diagnosis of nitrogen in apple trees based on multivariate calibration procedure using partial least squares regression (PLSR) and principal component regression (PCR) to establish the relationship between reflectance spectra in the near infrared region and nitrogen content of fresh- and dry-leaf. Several spectral pre-processing methods such as smoothing, mean normalization, multiplicative scatter correction (MSC) and derivatives were used to improve the robustness and performance of the calibration models. Norris first derivative with a seven point segment and a gap of six points on MSC gave the best result of partial least squares-1 PLS-1) model for dry-leaf samples with root mean square error of prediction (RMSEP) equal to $0.699g\;kg^{-1}$, and that the Savitzky-Golay first derivate with a seven point convolution and a quadratic polynomial on MSC gave the best results of PLS-1 model for fresh-samples with RMSEP of $1.202g\;kg^{-1}$. The best PCR model was obtained with Savitzky-Golay first derivative using a seven point convolution and a quadratic polynomial on mean normalization for dry leaf samples with RMSEP of $0.553g\;kg^{-1}$, and obtained with the Savitzky-Golay first derivate using a seven point convolution and a quadratic polynomial for fresh samples with RMSEP of $1.047g\;kg^{-1}$. The results indicate that nitrogen can be determined by the near infrared reflectance (NIR) technology for fresh- and dry-leaf of apple.

A fMRI study on the cerebral activity induced by Electro-acupuncture on Taichong(Liv3) (태충(太衝)(Liv3)의 전침자극(電鍼刺戟)이 fMRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Ha, Chi-hong;Lee, Hyun;Lim, Yun-kyoung;Hong, Kwon-eui;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.187-207
    • /
    • 2003
  • Objective: Recently, many studies have showed the evidences of the effect of the acupuncture treatment through scientific methods. One of these methods is functional MRI. We performed electro-acupuncture on Liv3 and observed the change of brain activation using fMRI. Methods: To see the effect of electro-acupuncture stimulation on Liv3. the experiment was carried out on 12 healthy volunteers. using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Liv3. 2 Hz of electric stimulation was given for 30 seconds. repeated five times. with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation. and smoothing was done with SPM99. Results : 1. Group averaged brain activation induced by bilateral electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 13, 18, 19, 22, 31, 39, 44, 2. Group averaged brain deactivation induced by bilateral Electro-acupuncture stimulation on Liv3 activates Brodman Area 4, 6, 9, 19, 36, 37, 39. 3. Group averaged brain activation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 2, 3, 6, 9, 10, 22, 40, 42, 43. 4. Group averaged brain deactivation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 18, 19, 28, 30, 31, 35, 37. 5. Brain region activated by motor stimulation activates Brodman Area 4, 6, 13, 19, 42.

  • PDF

A measurement of flow noise spectrum of an axisymmetric body (축대칭 3차원 물체의 유동 소음 스펙트럼 측정)

  • Park, Yeon-Gyu;Kim, Yang-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.725-733
    • /
    • 1998
  • The pressure fluctuation on the surface of a submerged body has been recognized as a dominant noise source. There have been many studies concerning the flow induced noise on a flat plate. However, the noise over an axisymmetric body has not been well reported. This paper addresses the way in which we have investigated the mechanism of noise generation due to an axisymmetric body. The associated experiments and signal processing methods are introduced. A 3-dimensional axisymmetric body whose length and diameter were 2 m and 10.4 cm, was prepared as a test specimen. The wall pressure on the surface of the body was measured in a large scale low noise wind tunnel at KIMM(Korea Institute of Machinery and Metals). To measure the wall pressure, we used two microphone arrays which were tangential and normal to the flow. Based on the measured signal, frequency-wavenumber spectrum which explains the structure of turbulence noise, was estimated. Tangential to the flow, there exists convective ridge at a relatively higher wavenumber region; this can cause spatial aliasing. To circumvent this problem, the cross spectrum was interpolated. The interpolation has been performed by unwrapping the phase and smoothing the cross spectrum. The phase unwrapping was done based on the Corcos model; the phase of cross spectrum decreases linearly with the distance between microphones. Aforementioned signal processings are possible by employing the experimental results that the estimated wavenumber spectrum quite resembles the Corcos model. We try to modify the Corcos model which is applicable to the flat plate, by altering the magnitude of cross spectrum to fit the experimental data more accurately. We proposed that this wavenumber spectrum model is suitable for the 3-dimensional axisymmetric body. Normal to the flow, there exists a little correlation between signals of different microphones. The circumferential wavenumber spectrum contains uniform power along the wavenumbers.

Adaptive Extended Bilateral Motion Estimation Considering Block Type and Frame Motion Activity (블록의 성질과 프레임 움직임을 고려한 적응적 확장 블록을 사용하는 프레임율 증강 기법)

  • Park, Daejun;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • In this paper, a novel frame rate up conversion (FRUC) algorithm using adaptive extended bilateral motion estimation (AEBME) is proposed. Conventionally, extended bilateral motion estimation (EBME) conducts dual motion estimation (ME) processes on the same region, therefore involves high complexity. However, in this proposed scheme, a novel block type matching procedure is suggested to accelerate the ME procedure. We calculate the edge information using sobel mask, and the calculated edge information is used in block type matching procedure. Based on the block type matching, decision will be made whether to use EBME. Motion vector smoothing (MVS) is adopted to detect outliers and correct outliers in the motion vector field. Finally, overlapped block motion compensation (OBMC) and motion compensated frame interpolation (MCFI) are adopted to interpolate the intermediate frame in which OBMC is employed adaptively based on frame motion activity. Experimental results show that this proposed algorithm has outstanding performance and fast computation comparing with EBME.

Wavelength selection by loading vector analysis in determining total protein in human serum using near-infrared spectroscopy and Partial Least Squares Regression

  • Kim, Yoen-Joo;Yoon, Gil-Won
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4102-4102
    • /
    • 2001
  • In multivariate analysis, absorbance spectrum is measured over a band of wavelengths. One does not often pay attention to the size of this wavelength band. However, it is desirable that spectrum is measured at only necessary wavelengths as long as the acceptable accuracy of prediction can be met. In this paper, the method of selecting an optimal band of wavelengths based on the loading vector analysis was proposed and applied for determining total protein in human serum using near-infrared transmission spectroscopy and PLSR. Loading vectors in the full spectrum PLSR were used as reference in selecting wavelengths, but only the first loading vector was used since it explains the spectrum best. Absorbance spectra of sera from 97 outpatients were measured at 1530∼1850 nm with an interval of 2 nm. Total protein concentrations of sera were ranged from 5.1 to 7.7 g/㎗. Spectra were measured by Cary 5E spectrophotometer (Varian, Australia). Serum in the 5 mm-pathlength cuvette was put in the sample beam and air in the reference beam. Full spectrum PLSR was applied to determine total protein from sera. Next, the wavelength region of 1672∼1754 nm was selected based on the first loading vector analysis. Standard Error of Cross Validation (SECV) of full spectrum (1530∼l850 nm) PLSR and selected wavelength PLSR (1672∼1754 nm) was respectively 0.28 and 0.27 g/㎗. The prediction accuracy between the two bands was equal. Wavelength selection based on loading vector in PLSR seemed to be simple and robust in comparison to other methods based on correlation plot, regression vector and genetic algorithm. As a reference of wavelength selection for PLSR, the loading vector has the advantage over the correlation plot since the former is based on multivariate model whereas the latter, on univariate model. Wavelength selection by the first loading vector analysis requires shorter computation time than that by genetic algorithm and needs not smoothing.

  • PDF

fMRI study on the cerebral activity induced by Electro-acupuncture on Sanyinjiao(Sp6) (삼음교(三陰交)(Sp6) 전침자극(電針刺戟)이 fMRI상 뇌활성변화(腦活性變化)에 미치는 영향(影響))

  • Hong, Kwon-eui;Lee, Byung-ryul;Lee, Hyun;Yim, Yun-kyoung;Kim, Yun-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.3
    • /
    • pp.86-103
    • /
    • 2003
  • Objective : Recently, many studies have showed the evidences of the effect of the acupunture treatment through scientific methods. One of these methods is functional MRI. We performed electro-acupunture on Sp6 and observed the changes of brain activation using fMRI. Methods : To see the effect of electro-acupunture stimulation on Sp6, the experiment was carried out on 12 healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp6, 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done with SPM99. Results : 1. Group averaged brain activation induced by bilateral eletro-acupunture stimulation on Sp6 activates Brodman Area 3, 7, 13. 2. Group averaged brain deactivation induced by bilateral eletro-acupunture stimulation on Sp6 activates Brodman Area 6, 38, 47. 3. Group averaged brain activation induced by unilateral(right side) eletro-acupunture stimulation on Sp6 activates Brodman Area 5, 6, 13, 17, 18, 19, 31, 38, 40 ptoms, back pain(32.5%) was the 4. Group averaged brain deactivation induced by unilateral(right side) eletro-acupunture stimulation on Sp6 activates Brodman Area 3, 4, 18, 21, 36, 38, 39. 5. Brain region activated by motor stimulation activates Brodman Area 3, 4, 6, 18, 19.

  • PDF

Comparison of optical reflectance spectrum at blade and vein parts of cabbage and kale leaves

  • Ngo, Viet-Duc;Ryu, Dong-Ki;Chung, Sun-Ok;Park, Sang-Un;Kim, Sun-Ju;Park, Jong-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • Objective of the study was to compare reflectance spectrum in the blade and the vein parts of cabbage and kale leaves. A total 6 cabbage and kale leaves were taken from a plant factory in Chungnam National University, Korea. Spectra data were collected with a UV/VIS/NIR spectrometer (model: USB2000, Ocean Optics, FL, USA) in the wavelength region of 190 - 1130 nm. Median filter smoothing method was selected to preprocess the obtained spectra data. We computed reflectance difference by subtraction of averaged spectrum from individual spectrum. To estimate correlation at different parts of cabbage and kale leaves, cross - correlation method was used. Differences between cabbage and kale leaves are clearly manifested in the green, red and near - infrared ranges. The percent reflectance of cabbage leaves in the NIR wavelength band was higher than that of kale leaves. Reflectance in the blade part was higher than in the vein part by 18%. Reflectance difference in the different parts of cabbage and kale leaves were clear in all of the wavelength bands. Standard deviation of reflectance difference in the vein part was greater for kale, while the value in the blade part was greater for cabbage leaves. Standard deviation of cross - correlation increased from 0.092 in the first sensor (UV/VIS) and 0.007 in the second sensor (NIR) to 0.099 and 0.015, respectively.

JND based Illumination and Color Restoration Using Edge-preserving Filter (JND와 경계 보호 평탄화 필터를 이용한 휘도 및 색상 복원)

  • Han, Hee-Chul;Sohn, Kwan-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.132-145
    • /
    • 2009
  • We present the framework for JND based Illumination and Color Restoration Using Edge-preserving filter for restoring distorted images taken under the arbitrary lighting conditions. The proposed method is effective for appropriate illumination compensation, vivid color restoration, artifacts suppression, automatic parameter estimation, and low computation cost for HW implementation. We show the efficiency of the mean shift filter and sigma filter for illumination compensation with small spread parameter while considering the processing time and removing the artifacts such as HALO and noise amplification. The suggested CRF (color restoration filter) can restore the natural color and correct color distortion artifact more perceptually compared with current solutions. For the automatic processing, the image statistics analysis finds suitable parameter using JND and all constants are pre-defined. We also introduce the ROI-based parameter estimation dealing with small shadow area against spacious well-exposed background in an image for the touch-screen camera. The object evaluation is performed by CMC, CIEde2000, PSNR, SSIM, and 3D CIELAB gamut with state-of-the-art research and existing commercial solutions.

Comparison of Topex/Poseidon sea levels data and Tide Gause sea levels data from the South Indian Ocean (남인도양에서의 해수면에 대한 위성자료(Topex/Poseidon 고도계)와 현장자료(Tide Gauge 해면계)간의 비교)

  • 윤홍주;김상우;이문옥;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model in this period. Making the corrections and smoothing the sea level data over 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms=11.4cm, c=0.55 and rms=5.38cm, and c=0.83 and rms=2.83cm for the Amsterdam, Crozet and Kerguelen plateau, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags($\tau$=10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of sterics(water temperature, density) and winds.

  • PDF