Park, Chul-Hoon;Sahn, Hyung-Ok;Shin, Han-Jae;Lee, Hyeong-Seok;Min, Yaung-Keun;Hyun, Hak-Chul
Journal of the Korean Society of Tobacco Science
/
v.29
no.2
/
pp.110-117
/
2007
In vitro toxicity tests such as cytotoxicity, mutagenicity and genotoxicity assay are useful for evaluating the relative toxicity of smoke or smoke condensates obtained from different cigarette configurations. A major disadvantage of these tests is relatively time-consuming, complicated and expensive. Recently, a cell-free glutathione consumption assay (GCA) as a rapid and simple screening method for the toxicity assessment of smoke has been reported by Cahours et al. (CORESTA, 2006). This study was carried out to assess the GCA application capable of predicting the toxicity of gas/vapor phase (GVP) of cigarette smoke and to identify individual compounds responsible for the glutathione (GSH) consumption in smoke. Each GVPs from 2R4F, standard cigarette, carbon filter cigarette (ExC) and new carbon filter cigarette (ExN), test cigarettes were collected by automatic smoking machine and evaluated the relative toxicity by GCA and neutral red uptake (NRU) assay. Toxic compounds existed in smoke were also chosen, relative toxicities of these compounds were screened by using two methods and compared individually. The overall order of toxicity by GCA was 2R4F > ExC > ExN, which was consistent with the result of Neutral Red Uptake assay. The levels of carbonyl compounds of ExN were lower than those of 2R4F and ExC, indicating that GSH consumption was associated with carbonyl compound yields. A major toxicant under current study is acrolein, which contributed to more than half of the GSH consumption. Collectively, the toxicity of GVP determined by GCA method may be mainly attributed to acrolein.
As part of a balanced testing battery, subchronic inhalation studies on rats are performed to ensure that proposed cigarette modifications do not increase the toxicity of smoke and to demonstrate any instances where a modification may actually contribute to harm reduction. For subchronic inhalation studies with aerosols, the OECD suggests an exposure regimen of 6 hours/day (OECD Guideline 413, 1981), but alternative regimens have also been published: 1 hour/day and $2{\times}1$ hour/day. The aim of this study was to validate a rodent nose-only exposure system for the assessment of inhalation toxicity of cigarette smoke. In this study, cigarette smoke exposure system is consisted of cigarette smoke generator, smoke concentration adjusting system, and 20-port nose-only exposure system. Male SD rats were exposed for 35 days ($2{\times}1$ hour/day) to 3R4F Reference cigarette smoke and analysed major monitoring items of OECD Gudeline 413. WTPM, was measured in the test atmosphere, respiratory function (Buxco Biosystems) during exposure, postexposure urinary exposure biomarkers and alveolar neutrophiles in BAL fluid (Day 35) were evaluated. Validation demonstrated steady WTPM ($257{\pm}20ug/L$, $502{\pm}27ug/L$) and spatial uniformity (<10%). Nose port temperature ($22{\sim}26^{\circ}C$ and RH (45~75%) were acceptable over 35 days. Reductions in respiratory rate and minute volume and increase in the neutrophiles in BALF and the urinary exposure biomarkers were observed cigarette smoke dose dependently. This validation and 35-day inhalation study has shown that the rodent nose-only exposure system may be useful in the inhalation toxicity assessment of cigarette smoke.
Tobacco smoking and secondhand smoke exposure are linked to a number of adverse health outcomes. There is a new concept of thirdhand smoke that is residual tobacco smoke contamination remained after the cigarette is extinguished. This paper reviews published studies examining the residual tobacco smoke. Tobacco smoke can be attached to various surfaces and reemitted to air for long period of time. The dynamic process can allow thirdhand smoke exposure to tobacco smoke without direct exposure to secondhand smoke. One critical evidence of the thirdhand smoke exposure was significantly high urinary cotinine level of infant who did not have direct secondhand smoke exposure. Potential exposure to new and more potent chemicals generated from chemical reactions between residual tobacco smoke and ambient air pollutants can get more attention. Considering toxicity and exposure route, children are uniquely susceptible to thirdhand smoke exposure. The review provides strong background information for thirdhand smoke but warrant more researches on this issue.
Journal of the Korean Applied Science and Technology
/
v.29
no.1
/
pp.129-140
/
2012
Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.
This study was conducted to evaluate the effect of triacetin(TA) treatment during manufacturing carbon dual filter for the adsorption of cigarette smoke components by activated carbons. The measurements were carried out by separation of activated carbon from carbon dual filter, and the specific surface area analyzed. The specific surface area of activated carbon from the domestic cigarette filter and from the foreign cigarette filter by degassing at 9$0^{\circ}C$ was 163$\pm$32$m^2$/g, and 16.6$\pm$1.9$m^2$/g, respectively. Those values were very lower than that of degassing at 35$0^{\circ}C$ (Domestic brand: 952$\pm$30$m^2$/g, and Foreign brand: 847$\pm$73$m^2$/g). By comparing the adsorption capacity of acetone and benzene with and without triacetin treated activated carbon, there was a 20% reduction of adsorption capacity by 5% triacetin treatment. Also, from the cilia toxicity test with carbon dual filter treated 0 % TA and 8 % TA, the cilia survival time was 706$\pm$74sec. and 603$\pm$64sec. for 0% TA and 8% TA, respectively. The delivery rate of vapour phase of cigarette smoke, which consists of main components of cilia toxicity, was higher at 8% TA filter than 0 % TA filter. Our results indicate that the treated TA covered the micro-pore of activated carbon, and then reduced specific surface area, finally, decreased the adsorption of vapour phase from cigarette smoke.
In this study, we have performed several tests for composite plastic materials to be applied on interior materials of a vehicle to identify their combustion characteristics using cone calorimeter, smoke density chamber and toxicity index chamber. We have prepared a total of 12 samples for 4 major parts of a vehicle wherein each major part has 3 different materials. The results of cone calorimeter test showed ignition time of PVC sheet and PVC leather were 2s. The 8 samples showed under less than 10s of ignition time. The sample comprising Nylon and PE had the biggest maximum heat release rate of 635 $kW/m^2$. The sample comprising Rubber showed the smallest maximum heat release rate but with the biggest total heat release. The results of smoke density chamber test showed the sample that is made up with Rubber had the biggest specific optical smoke density. The sample comprising PVC leather and PUR showed the biggest VOF4 which enables the initial smoke production. The results of toxicity index test showed that all samples contained carbon dioxide content exceeding its lethal concentration. The sample comprising PVC showed high content of hydrogen chloride and hydrogen bromide. The PVC sheet showed the biggest toxicity index calculated by using lethal concentration and test results. Toxicity index of all sample wes over 1.
Park, Won-Hee;Lee, Han-Su;Chang, Hee-Chul;Jang, Yong-Jun
Proceedings of the KSR Conference
/
2007.11a
/
pp.1213-1217
/
2007
In this paper some sets of numerical simulations for passenger evacuation in a fire occurred underground station under various smoke-control ventilation modes. Passenger evacuation flows are calculated by EXODUS program. As input data for EXODUS program, distributions of temparature, smoke and toxicity due to fire in the underground station are evaluated by Fire Dyanamic Simulator (FDS).
Combustion characteristics and toxicity of combustion gas of wallpaper samples were analyzed to evaluate the fire risk of wallpaper furnished in living space. In this study ash residue ratio was measured with high temperature electric furnace, and thermal analysis was carried out with TGA. Combustion time and smoke concentration were measured with cone heater and combustion gas analyzer. Smoke density of samples was measured using smoke chamber of ASTM E 662. The experimental results were showed as followings. Pyrolysis of silk wallpaper started at lower temperature compared to the other samples. It means that the silk wallpaper can be ignited at low heat flux and will have more fire risk than the others. Ignition time by radiation heat flux of silk wallpaper is shorter compared to the other samples, so evacuation time must be reduced. In the case of vinyl coated silk wall paper, carbon mono oxide concentration is the highest and the toxicity and damage effect to consciousness was stronger compared to the other samples. Smoke density of silk wall paper and fire retardant mixed coated silk wall paper were very high due to vinyl coating.
Park, Soo-Young;Lee, Woo-Seok;Yeo, Han-Seung;Im, Hong-Soon
Fire Science and Engineering
/
v.20
no.4
s.64
/
pp.26-32
/
2006
Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.
Transactions on Electrical and Electronic Materials
/
v.3
no.3
/
pp.34-38
/
2002
In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.