• Title/Summary/Keyword: Smoke toxicity

Search Result 67, Processing Time 0.024 seconds

Toxicity Assessment of Gas Phase in Cigarette Smoke Using Cell-free Assay

  • Park, Chul-Hoon;Sahn, Hyung-Ok;Shin, Han-Jae;Lee, Hyeong-Seok;Min, Yaung-Keun;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.2
    • /
    • pp.110-117
    • /
    • 2007
  • In vitro toxicity tests such as cytotoxicity, mutagenicity and genotoxicity assay are useful for evaluating the relative toxicity of smoke or smoke condensates obtained from different cigarette configurations. A major disadvantage of these tests is relatively time-consuming, complicated and expensive. Recently, a cell-free glutathione consumption assay (GCA) as a rapid and simple screening method for the toxicity assessment of smoke has been reported by Cahours et al. (CORESTA, 2006). This study was carried out to assess the GCA application capable of predicting the toxicity of gas/vapor phase (GVP) of cigarette smoke and to identify individual compounds responsible for the glutathione (GSH) consumption in smoke. Each GVPs from 2R4F, standard cigarette, carbon filter cigarette (ExC) and new carbon filter cigarette (ExN), test cigarettes were collected by automatic smoking machine and evaluated the relative toxicity by GCA and neutral red uptake (NRU) assay. Toxic compounds existed in smoke were also chosen, relative toxicities of these compounds were screened by using two methods and compared individually. The overall order of toxicity by GCA was 2R4F > ExC > ExN, which was consistent with the result of Neutral Red Uptake assay. The levels of carbonyl compounds of ExN were lower than those of 2R4F and ExC, indicating that GSH consumption was associated with carbonyl compound yields. A major toxicant under current study is acrolein, which contributed to more than half of the GSH consumption. Collectively, the toxicity of GVP determined by GCA method may be mainly attributed to acrolein.

Validation of a Rodent Nose-only Exposure System for Inhalation Toxicity Evaluation of Cigarette Smoke (담배 흡입독성 평가를 위한 설치류 담배연기노출시스템의 유효화)

  • Sohn, Hyung-Ok;Lee, Hyeong-Seok;Shin, Han-Jae;Park, Chul-Hoon;Yoo, Ji-Hye;Jang, Mi;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • As part of a balanced testing battery, subchronic inhalation studies on rats are performed to ensure that proposed cigarette modifications do not increase the toxicity of smoke and to demonstrate any instances where a modification may actually contribute to harm reduction. For subchronic inhalation studies with aerosols, the OECD suggests an exposure regimen of 6 hours/day (OECD Guideline 413, 1981), but alternative regimens have also been published: 1 hour/day and $2{\times}1$ hour/day. The aim of this study was to validate a rodent nose-only exposure system for the assessment of inhalation toxicity of cigarette smoke. In this study, cigarette smoke exposure system is consisted of cigarette smoke generator, smoke concentration adjusting system, and 20-port nose-only exposure system. Male SD rats were exposed for 35 days ($2{\times}1$ hour/day) to 3R4F Reference cigarette smoke and analysed major monitoring items of OECD Gudeline 413. WTPM, was measured in the test atmosphere, respiratory function (Buxco Biosystems) during exposure, postexposure urinary exposure biomarkers and alveolar neutrophiles in BAL fluid (Day 35) were evaluated. Validation demonstrated steady WTPM ($257{\pm}20ug/L$, $502{\pm}27ug/L$) and spatial uniformity (<10%). Nose port temperature ($22{\sim}26^{\circ}C$ and RH (45~75%) were acceptable over 35 days. Reductions in respiratory rate and minute volume and increase in the neutrophiles in BALF and the urinary exposure biomarkers were observed cigarette smoke dose dependently. This validation and 35-day inhalation study has shown that the rodent nose-only exposure system may be useful in the inhalation toxicity assessment of cigarette smoke.

Scientific Evidences of Thirdhand Smoke (3차 간접흡연의 과학적 증거의 고찰)

  • Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.77-81
    • /
    • 2010
  • Tobacco smoking and secondhand smoke exposure are linked to a number of adverse health outcomes. There is a new concept of thirdhand smoke that is residual tobacco smoke contamination remained after the cigarette is extinguished. This paper reviews published studies examining the residual tobacco smoke. Tobacco smoke can be attached to various surfaces and reemitted to air for long period of time. The dynamic process can allow thirdhand smoke exposure to tobacco smoke without direct exposure to secondhand smoke. One critical evidence of the thirdhand smoke exposure was significantly high urinary cotinine level of infant who did not have direct secondhand smoke exposure. Potential exposure to new and more potent chemicals generated from chemical reactions between residual tobacco smoke and ambient air pollutants can get more attention. Considering toxicity and exposure route, children are uniquely susceptible to thirdhand smoke exposure. The review provides strong background information for thirdhand smoke but warrant more researches on this issue.

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

Triacetin이 탄소복합 필터의 연기성분 흡착능에 미치는 영향

  • 김정열;신창호;김종열
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.205-209
    • /
    • 1998
  • This study was conducted to evaluate the effect of triacetin(TA) treatment during manufacturing carbon dual filter for the adsorption of cigarette smoke components by activated carbons. The measurements were carried out by separation of activated carbon from carbon dual filter, and the specific surface area analyzed. The specific surface area of activated carbon from the domestic cigarette filter and from the foreign cigarette filter by degassing at 9$0^{\circ}C$ was 163$\pm$32$m^2$/g, and 16.6$\pm$1.9$m^2$/g, respectively. Those values were very lower than that of degassing at 35$0^{\circ}C$ (Domestic brand: 952$\pm$30$m^2$/g, and Foreign brand: 847$\pm$73$m^2$/g). By comparing the adsorption capacity of acetone and benzene with and without triacetin treated activated carbon, there was a 20% reduction of adsorption capacity by 5% triacetin treatment. Also, from the cilia toxicity test with carbon dual filter treated 0 % TA and 8 % TA, the cilia survival time was 706$\pm$74sec. and 603$\pm$64sec. for 0% TA and 8% TA, respectively. The delivery rate of vapour phase of cigarette smoke, which consists of main components of cilia toxicity, was higher at 8% TA filter than 0 % TA filter. Our results indicate that the treated TA covered the micro-pore of activated carbon, and then reduced specific surface area, finally, decreased the adsorption of vapour phase from cigarette smoke.

  • PDF

A Study on the Fire Risk of Car Interior Materials (자동차 내장재의 화재위험성에 관한 연구)

  • Lee, Hae-Pyeong;Kim, Young-Tak
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • In this study, we have performed several tests for composite plastic materials to be applied on interior materials of a vehicle to identify their combustion characteristics using cone calorimeter, smoke density chamber and toxicity index chamber. We have prepared a total of 12 samples for 4 major parts of a vehicle wherein each major part has 3 different materials. The results of cone calorimeter test showed ignition time of PVC sheet and PVC leather were 2s. The 8 samples showed under less than 10s of ignition time. The sample comprising Nylon and PE had the biggest maximum heat release rate of 635 $kW/m^2$. The sample comprising Rubber showed the smallest maximum heat release rate but with the biggest total heat release. The results of smoke density chamber test showed the sample that is made up with Rubber had the biggest specific optical smoke density. The sample comprising PVC leather and PUR showed the biggest VOF4 which enables the initial smoke production. The results of toxicity index test showed that all samples contained carbon dioxide content exceeding its lethal concentration. The sample comprising PVC showed high content of hydrogen chloride and hydrogen bromide. The PVC sheet showed the biggest toxicity index calculated by using lethal concentration and test results. Toxicity index of all sample wes over 1.

Simulations of the Passenger Evacuation in a Fire occurred Underground Station under Various Smoke-Control Ventilation Modes (지하역사 화재발생시 제연모드에 따른 승객피난 예측)

  • Park, Won-Hee;Lee, Han-Su;Chang, Hee-Chul;Jang, Yong-Jun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1213-1217
    • /
    • 2007
  • In this paper some sets of numerical simulations for passenger evacuation in a fire occurred underground station under various smoke-control ventilation modes. Passenger evacuation flows are calculated by EXODUS program. As input data for EXODUS program, distributions of temparature, smoke and toxicity due to fire in the underground station are evaluated by Fire Dyanamic Simulator (FDS).

  • PDF

A study on the Combustion Characteristics of Wall Paper (내장벽지의 연소특성에 관한 연구)

  • Oh, Kyu-Hyung;Choi, Yeon-Yi;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.90-97
    • /
    • 2007
  • Combustion characteristics and toxicity of combustion gas of wallpaper samples were analyzed to evaluate the fire risk of wallpaper furnished in living space. In this study ash residue ratio was measured with high temperature electric furnace, and thermal analysis was carried out with TGA. Combustion time and smoke concentration were measured with cone heater and combustion gas analyzer. Smoke density of samples was measured using smoke chamber of ASTM E 662. The experimental results were showed as followings. Pyrolysis of silk wallpaper started at lower temperature compared to the other samples. It means that the silk wallpaper can be ignited at low heat flux and will have more fire risk than the others. Ignition time by radiation heat flux of silk wallpaper is shorter compared to the other samples, so evacuation time must be reduced. In the case of vinyl coated silk wall paper, carbon mono oxide concentration is the highest and the toxicity and damage effect to consciousness was stronger compared to the other samples. Smoke density of silk wall paper and fire retardant mixed coated silk wall paper were very high due to vinyl coating.

The Experimental Study for the Smoke Optical Density and Toxic Gases of Sandwich Panel Insulations(Single Chamber Method) (샌드위치패널 단열재의 연기농도 및 연소독성가스에 대한 실험적 연구(연소챔버법))

  • Park, Soo-Young;Lee, Woo-Seok;Yeo, Han-Seung;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.26-32
    • /
    • 2006
  • Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.