• Title/Summary/Keyword: Smoke protection

Search Result 183, Processing Time 0.031 seconds

Synthesis of Alkylenediaminoalkyl-bis-Phosphonic Acid Derivatives (알킬렌디아미노알킬-비스-포스폰산 유도체의 합성)

  • Chung, Yeong-Jin;Jin, Eui
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Four kinds of new alkylenediaminoalkyl-bis-phosphonic acid derivatives with alkylenediaminoalkyl functional groups in the molecule were synthesized and their smoke density(Ds) were tested. These alkylenediaminoalkyl-bis-phosphonic acid derivatives were prepared in yields(76-97.3%) by one step reaction of the phosphorus acid with amine and aldehyde. Smoke density was measured by the method of ASTM E 662. The values of smoke density were obtained from 234.7 to 437.9. The smoke density of compounds with two phosphonic acid structures were increased more than that of compounds with one phosphonic acid structure. In addition, there was correlation between the smoke density and the number of nitrogen atoms in amino group attached to mono- or di-phosphonic acids group.

A Study on Smoke Control Characteristic by the Effect off Jet Fan Installation Distance (제트팬 이격거리에 따른 연기제어특성에 관한 연구)

  • Kim, Jong-Yoon;Jeon, Yong-Han;Seo, Tae-Beom;Yoo, Ji-Oh;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.16-23
    • /
    • 2008
  • In this research, the visualization experiment for a scaling tunnel was conducted to establish the optimum fire protection system in tunnel fires. In order to find the optimal operating condition of jet fan with the fire, the characteristics of smoke propagation was considered to find the optimal operating condition of jet fan at the time of tunnel fire, the concentration of smoke was measured experimentally for various jet fan position and it's operating condition. As a result, when jet fan in the vicinity of fire operates at the upstream, the back-layering of the smoke should be considered with separation distance from the fire source. The distance between the jet fan and the fire should be longer than 50 m. On the other hand, when the vicinity jet fan operates at the downstream, the back-layering of smoke does not occur, but stratification is not maintained because the smoke dispersion occurs at the downstream due to the operation of the jet fan.

Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel (중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.9-17
    • /
    • 2016
  • In the case of a medium length road tunnel, the installation of a smoke control facility is not mandatory so users can suffer considerable injuries if a fire breaks out. Therefore, this study analyzed the high-temperature air and toxic gas generated by fire proliferating with time when a smoke barrier is not installed and when the installation interval is 100, 150, 200, and 250 m through 3-dimensional numerical analysis, evacuation simulation, and Quantitative Risk Assessment Methodology targeting the medium length road tunnel. As a result, the diffusion of the high-temperature air and toxic gas occurring from the a fire was delayed when the smoke barrier was installed in a medium length road tunnel compared to that when it was not installed. In addition, when the installation interval of a smoke barrier was 100m and the numerical analysis target was 100m, the diffusion of high-temperature air and toxic gas generated by the fire was delayed more than in the other cases, which was most suitable for tunnel users to evacuate.

Synthesis of Dialklyaminoalkyl Phosphonic Acid and Bis(dialklyaminoalkyl) Phosphinic Acid Derivatives (디알킬아미노알킬 포스폰산과 비스-디알킬아미노알킬 포스핀산 유도체의 합성)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.583-587
    • /
    • 2012
  • Six kinds of new aminoalkyl phosphonic acid or aminoalkyl phosphinic acid derivatives with mono-dialkylamino, or di-dialkylamino functional groups in the molecule were synthesized and their smoke densities were tested. The aminoalkyl phposphonic acid or aminoalkyl phosphinic acid derivatives were synthesized with quantitative yields of 90~98.6% by one step reaction of the phosphorus acid or hypo phosphorous acid with amine and aldehyde. The smoke density was measured by the ASTM E 662 method. Values of the smoke density were obtained from 224.5 to 256.6. The smoke density of the compounds with two aminoalkyl structures decreased more than that of compounds with one aminoalkyl structure. In addition, there was no correlation between the smoke density and the number of carbon atoms in the alkyl group attached to the amino group.

Investigation of Performent Standards for the Fire Damper (방화Damper의 성능기준 고찰)

  • Jo, Jung-Dal
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF

A study on the variation of orifice diameter in a straight pipe giving dqual-sampling rate (직선배관에서 균일한 공기 흡입을 하는 오리피스 직경변화에 대한 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.24
    • /
    • pp.17-22
    • /
    • 1998
  • The objective of this paper is to investigate the variation of orifice diameter in a straight pipe which can give equal-sampling rate. This can be utilized for designing orifice in air-sampling smoke detector. The elements which should be considered for designing orifices was presented and the calculation procedure was also given in this paper. The effects of pipe length, the number of orifices, fan pressure was decribed.

  • PDF

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.