• Title/Summary/Keyword: Smoke detectors

Search Result 54, Processing Time 0.021 seconds

An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses (랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구)

  • Choi, Ki Ok;Kim, Dong Suck;Hong, Sung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

A Study on the Corrosion Resistance Test of Smoke Detectors (연기감지기의 내식시험에 관한 연구)

  • Kim, Hyeong-Gweon;Yoon, Hun-Ju;Kwon, Seong-Pil;SaKong, Seong-Ho;Back, Chang-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

A Study on the Comparison of Aspirating Smoke Detector and General Smoke Detector Detection Time according to the Fire Speed and Location of Logistics Warehouse through FDS (화재시뮬레이션을 통한 물류창고 화재 속도와 위치에 따른 공기흡입형 감지기와 일반 연기 감지기 감지시간 비교에 관한 연구)

  • SangBum Lee;MinSeok Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.608-623
    • /
    • 2023
  • Purpose: Recently, the number of logistics warehouses has been on the rise. In addition, as the number of such logistics warehouses increases, number of fire accidents also increases every year, increasing the importance of preventing fires in large logistics warehouses. Method: investigated aspirating smoke detectors that are emerging as adaptive fire detectors in logistics warehouses. Then, through fire simulation (FDS), logistics warehouse modeling was conducted to compare and analyze the detection speed of general smoke detectors and aspirating smoke detectors according to four stages of fire growth and three locations of fire in the logistics warehouse. Result: Growth speed in Slow-class fires and Mediumclass fires, the detection speed of aspirating smoke detectors was faster regardless of the location of the fire. However, in Fast-class fires and Ultra-Fast-class fires, it was confirmed that the detection speed of general smoke detectors was faster depending on the location of the fire. Conclusion: It was confirmed that the detection performance of the aspirating smoke detector decreased as the fire growth speed increased and the location of the fire occurred further than the receiver of the aspirating smoke detector. Therefore, even if an aspirating smoke detector is installed in a warehouse that stores combustibles with high fire growth rates, it is judged that an additional smoke detector is attached far away from the receiver of the general smoke detector to increase fire safety.

Study of the Improvement of False Fire Alarms in Analog Photoelectric Type Smoke Detectors (아날로그 광전식 연기감지기 비화재보 개선에 대한 연구)

  • Seo, Byung Keun;Nam, Sang Gu
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.108-115
    • /
    • 2016
  • Fire detectors play an important role in alerting the related people to the initial stages of fire to protect assets and life. Therefore, the performance in detecting fires in the early stages without the risk of false alarms is important. Owing to a recent revision of the national fire safety standards to install smoke detectors in living rooms used for sleeping, staying, hospitalizing in apartment house/efficiency apartment/lodging facility/medical facility/facility for elderly and young, the application of smoke detectors is increasing. On the other hand, there is lack of research in preventing false alarms. This study improved algorithms to prevent false alarms in analog photoelectric smoke detector's due to sudden dust and better classify pollution and fire signals through a self-compensatory function. Through this study, alternatives are suggested to reduce the number of false alarms of Analog Photoelectric smoke detectors, and prevent financial losses due to false alarms.

연기와 연기감지기술에 대한 고찰

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.15
    • /
    • pp.28-38
    • /
    • 1993
  • This report is explain the nature of smoke and the principle of smoke detection. The object of this research is to understand the hazard of smoke and select the optimum smoke detectors, according to the types of smoke and the particle size of smoke produced by fire

  • PDF

Revision of the Input Parameters for the Prediction Models of Smoke Detectors Based on the FDS (FDS 기반의 연기감지기 예측모델을 위한 입력인자 재검토)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.44-51
    • /
    • 2017
  • Accurate predictions of the activation time for smoke detectors using a fire simulation is are required to ensure the reliability of the RSET (Required Safe Egress Time) calculation in the process of PBD (Performance-Based Design). The objective of this study was to enhance the accuracy of input parameters for the numerical models of smoke detector based on the FDS. To this end, a Fire Detector Evaluator (FDE) developed in previous studies was improved. The uniformities of flow and smoke inside the FDE were improved and accurate measurements of the obscuration per meter (OPM) related to detector operation were also performed through a decrease in the forward scattering of smoke particles. The input parameters using the improved FDE showed a significant difference from the previous FDE quantitatively. In particular, a larger difference was found in a photoelectric detector compared to an ionization detector. Considering that the operating conditions of smoke detectors are affected by the detector type, combustibles, smoke particulars, and color, the database (DB) on the input parameters for various detectors and combustibles should be built to improve the reliability of PBD in future studies.

PERFORMANCE EVALUATION OF PASSENGERS' EVACUATION FOR SMOKE-CONTROL MODES IN A SUBWAY STATION (지하역사 제연모드 승객피난 성능평가)

  • Park, Won-Hee;Chang, Hee-Chul;Jung, Woo-Sung;Lee, Han-Su
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.8-12
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by building EXODUS V.4.0.

Performance Evaluation of Passengers' Evacuation for Smoke-Control Modes in a Subway Station Based on CFD Results (전산열유체 해석결과를 이용한 지하역사 제연모드 승객피난 성능평가)

  • Park, Won-Hee;Jang, Yong-Jun;Lee, Han-Su;Chang, Hee-Chul;Lee, Duck-Hee
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.276-279
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by buildingEXODUS V 4.0.

  • PDF

CHARACTERISTICS OF SMOKE CONCENTRATION PROFILES WITH UNDERGROUND UTILITY TUNNEL FIRE

  • Kim Hong Sik;Hwang In Ju;Kim Youn-Jea
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Accurate prediction of the fire-induced air velocity, temperature and smoke flow in underground utility tunnel becomes more important for the optimization of design and placement of heat and smoke detectors. In order to improve the safety of underground utility tunnel systems, the behaviors of fire-induced smoke flow and temperature distributions are investigated. Especially, two different cross-sectional shapes of tunnel, such as rectangular and circular types are modeled. Also, fire source is modeled as a volumetric heat source. Three-dimensional thermal-flow characteristics in an underground tunnel are solved by means of FVM using SIMPLE algorithm. The effects of shape geometry on the fire-induced flow characteristics are graphically depicted. It is desirable that heat and smoke detectors are installed on the cables and the top of the wall.