IOT기술을 이용한 유무선 통합 가스검출 시스템 구현 (System of gas sensor for conbinating wire and wireless using Internet of Things)

  • 방용기;강경식
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증 (Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments)

  • 안현성
    • 토지주택연구
    • /
    • 제13권4호
    • /
    • pp.105-114
    • /
    • 2022
  • 화재감지기는 비화재보가 많이 발생함에 따라서 신속하게 감지기를 확인해야 하지만 일반감지기는 주소기능이 없어 신속한 대응에 한계가 있다. 주소 기능을 갖는 아날로그감지기 등을 적용하면 해결되지만 기존 공동주택의 경우 교체기간, 교체 비용, 선로의 사용 등의 문제로 인해 설비의 전면 교체에는 한계가 있다. 이에 별도로 기존아파트에 적용성을 고려한 맞춤형 설비가 필요하다. 본 연구에서는 기존아파트의 특성을 고려하여 주소형 감지기와 중계기를 설계하여 중계기에서 감지기 위치를 확인할 수 있는 시스템을 개발하였다. 주소형 감지기는 정온식과 광전식 감지기를 설계하였으며, 주소형 중계기는 FND를 추가하여 감지기 위치 확인이 가능하게 하였다. 선로의 종류, 길이를 고려하여 성능검증을 하였으며, 단선에러 동작과 일반감지기와의 호환성 등을 추가 검증하였다.

적외선 불꽃감지기 개발연구 (The Research & Development of Infra-Red Flame Detector)

  • 이복영;권오승;정창기;박상태;조성수
    • 한국화재소방학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-6
    • /
    • 2000
  • 가연물 연소시 불꽃의 복사에너지 Spectrum분석을 통하여 태양광, 인공광과 Flame의 spectrum특성해석으로 불꽃감지기술을 정립하였다. IR파장대의 복사에너지를 감지하기 위해 초전형 감지소자개발로 PZT소자를 개발하였으며, Band Pass Filter와 회로안정화기술을 적용한 적외선 불꽃화재감지기를 개발하였다. 시작품의 성능은 신뢰성 있는 적외선 불꽃감지기로 검증이 되었으며, 연구결과는 휘발유, 석유화학제품의 연소시 발생되는 불꽃을 조기에 감지하는 복사에너지 감지기가 개발되었다.

  • PDF

Wireless Sensor Networks based Forest Fire Surveillance System

  • Son, Byung-Rak;Kim, Jung-Gyu
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.123-126
    • /
    • 2005
  • Wireless Sensor Networks will revolutionize applications such as environmental monitoring, home automation, and logistics. We developed forest fire surveillance system. In this paper, Considering the fact that in Korea, during November to May, forest fires occur very frequently causing catastrophic damages on the valuable environment, Although exists other forest fire surveillance system such as surveillance camera tower, infrared ray sensor system and satellite system. Preexistence surveillance system can't real-time surveillance, monitoring, database and automatic alarm. But, forest fire surveillance system(FFSS) support above. In this paper, we describes a system development approach for a wireless sensor network based FFSS that is to be used to measure temperature and humidity as well as being fitted with a smoke detector. Such a device can be used as an early warning fire detection system and real-time surveillance in the area of a bush fire or endangered public infrastructure. Once the system has being development, a mesh network topology will be implemented with the chosen sensor node with the aim of developing a sophisticated mesh network.

  • PDF

휴대용 연기감도시험기의 표준에 관한 연구 (A study on the Standard of Smoke Detector Sensitivity Test Equipment)

  • 김형권;권성필;윤헌주;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.194-199
    • /
    • 2009
  • 소방대상물에 기 설치되어 있는 연기감지기에 대한 정밀한 감지 성능 시험의 요구에 부응하기 위하여 현장에서 국내 기술기준에 적합하게 시험할 수 있는 휴대용 연기감도 시험기에 대하여 연구하였다. 휴대용 연기감도시험기는 점검 현장에서 간이로 감도시험을 할 수 있도록 연기원으로 동양 2호지를 사용하여 연기를 발생시키고, 농도를 제어하고 일정풍속 유지가 가능하여 현장에 설치된 연기감지기의 정밀한 시험이 가능하도록 하였다.

  • PDF

디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용 (Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구 (A study on prediction and improvement method of fire risk for a newly built college dormitory)

  • 김별;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.228-234
    • /
    • 2016
  • 승선생활관은 거주밀도가 높으며 유동인구도 특정한 시간에 몰리는 특징을 가지기 때문에 화재와 같은 재난이 발생할 경우 큰 인명피해 발생으로 이어질 수 있다. 이에 이 연구에서는 국내 K대학의 신축 승선생활관을 대상으로 화재 시뮬레이션 프로그램인 FDS를 사용하여 화재발생 시의 위험성을 예측하고 이에 따른 문제점을 분석하여 개선방안을 제시하였다. 연구결과를 정리하면 다음과 같다. 승선생활관 다림질실에서 화재발생 시, 발화 후 65초에 연기감지기가 작동하고, 13초 뒤인 78초에 스프링클러가 작동하기 시작한다. 온도 및 일산화탄소 농도는 각각 241초, 248초에 허용기준 값에 도달하지만, 발화 후 66초에 허용 가시거리 값에 도달하기 때문에, 화재발생 후 적어도 1분 이내에 준비를 끝내고 피난을 개시해야 인명피해가 발생하지 않을 것으로 예측된다. 이 기숙사의 화재위험성 예측 결과를 종합해 보았을 때, 인명안전에 가장 위험한 요소를 가시거리 값으로 판단할 수 있다. 가시거리 확보를 위해 제연설비를 설치할 경우, 제연설비 설치 후 승선생활관 복도의 연기확산이 개선되는 것을 확인할 수 있었다.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

공동주택 화재감지 및 소화성능개선에 관한 연구 (A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses)

  • 이채원;손봉세
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.38-44
    • /
    • 2015
  • 본 연구는 공동주택에 일반적으로 설치하는 열감지기와 스프링클러헤드의 작동에 관한 문제점과 개선 대책을 제시한 연구이다. 2010년 인구주택 조사에 의하면, 공동주택은 전체 주거시설의 71.6%이며 최근 7년간 소방방재청의 화재통계 자료에 의하면, 매년 전체 화재의 약 25.0%, 인명피해는 46.4%가 공동주택에서 발생한 것으로 나타났다. 따라서 본 연구에서는 공동주택의 화재안전에 대한 개선대책을 수립하기 위하여 화재원인과 특성을 파악하였고, 국내 공동주택의 대표적인 평형을 대상으로 가상화재시뮬레이션을 수행하였다. 가상화재시뮬레이션의 시나리오는 기존 공동주택에 설치된 표준형 스프링클러헤드와 열감지기, 최근에 설치가 요구되는 주거전용 스프링클러헤드와 연기감지기의 작동시간 등을 비교 분석하였다. 시뮬레이션 수행결과 기존 공동주택에 설치된 표준형 스프링클러헤드와 열감지기는 감지 및 작동시간이 늦어 조기화재진압에 불리한 것으로 나타났으므로 주거전용 스프링클러헤드와 연기 열복합형감지기로 교체 설치하는 것이 필요하다. 또한, 기존 공동주택 중 스프링클러소화설비의 설치가 제외된 층에도 스프링클러소화설비 설치를 고려해야 한다. 특히, 공동주택 안전관리의 효율화를 위하여 선진국과 같이 원격으로 주거공간의 소방시설을 점검할 수 있도록 시스템을 구축할 필요가 있다.

복합상영관 화재에 대한 화재모델링의 적용 (A Study on the Application of Fire Modeling for Multiplex Cinema Theater)

  • 허준호;김종훈;노삼규;김운형
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.42-48
    • /
    • 2004
  • 다중이용시설의 화재 시 온도분포 및 연기유동 모델링은 결정론적 모델(Deterministic Model)인 존모델 (Zone Model)과 필드모델(Field Model)이 주로 사용되고 있다. 존모델은 공간을 두개의 지역으로 구분하여 화재현상을 분석하고, 필드모델은 공간을 다수의 Cell로 구분하여 분석하고 있으나 두 모델의 비교치에 대해서는 효용성 검증에 어려움을 겪고 있다. 따라서 화재현상의 모델링에 따른 수치적 이해와 관련자료의 검증을 통하여 실 상황에 보다 근접한 새로운 모델의 개발이 요구된다. 본 논문에서는 두 모델을 복합상영관의 실내공간에 적용하여 그 효용성을 분석해본 결과 공간 평균분포도에서는 존모델이, 세부적 공간현상에서는 필드모델의 적용이 적절한 것으로 판단된다. 또한 구체적인 화재의 성상과 감지기의 위치선정, 연기제어를 위한 제연설비의 검토를 위해서는 필드모델의 활용이 더욱 효과적이다.