• 제목/요약/키워드: Smoke density test

검색결과 56건 처리시간 0.023초

철도차량용 고무바닥재의 연기발생에 관한 실험적 연구 (An Experimental Study on Smoke Generation of Rubber Floor for Railway Vehicle)

  • 박영주
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.15-20
    • /
    • 2018
  • In this study, we have performed the Cone Calorimeter test and Smoke density test in accordance with ISO 5660-1 and ASTM E662 respectively to check the smoke production characteristics of rubber flooring materials for railway vehicle. Early in the ASTM E662 test, more smoke was produced in the flame mode test than non-flame mode test, but later more smoke was produced in non-flame mode test. The correlation($R^2$) between TSR(Total Smoke Release) by ISO 5660-1 and Ds(Specific Optical Density) by ASTM E662 Flame mode was 0.782. The $R^2$ between TSR by ISO 5660-1 and Ds by ASTM E662 Non-flame was 0.930.

Cone-Calorimeter와 연기밀도챔버를 이용한 고무발포단열재의 연기밀도 비교 (Smoke Density Comparison of Rubber Foam Insulator by the test between Cone-Calorimeter and Smoke Density-Chamber)

  • 조희기;이덕희;이철규;이동우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.941-946
    • /
    • 2005
  • Kinds of Sound & Thermal Insulator are being used for materials of railroad vehicles as a barrier of beat and noise. Glass Wool, PE foam, PP foam are such kinds of materials. In case of fire, it shows various combustion properties. In this study, we compared the Smoke Density of the Rubber Foam Insulator by test between Cone-Calorimeter and Smoke Density-Chamber. The results showed that the Rubber Foam Insulator had an important role in the insulator thickness and the test method, We forecast the smoke density by test between Cone-Calorimeter and Smoke Density-Chamber.

  • PDF

합성목재의 연기밀도특성 분석에 관한 연구 (A Study on the Analysis of Smoke Density Characteristics for Wood-Plastic Composites)

  • 신백우;송영호;이동호;정국삼
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.119-124
    • /
    • 2011
  • 본 연구에서는 최근 조경 및 건축자재로서 각광받고 있는 합성목재의 화재위험성을 알아보기 위하여 콘칼로리미터 실험과 연기밀도 실험 장치를 이용하여 연기밀도 특성을 살펴보았다. 일반목재인 적송과 방부처리를 한 방부목에 대하여도 동일한 실험을 통하여 합성목재와의 연기밀도 특성을 비교하였다. 콘칼로리미터 실험결과 CO 및 $CO_2$ 발생량과 총 연기 발생량 값은 적송 및 방부목에 비해 합성목재가 높게 나타났다. 또한 연기밀도 실험 장치를 통한 최대연기밀도(Dm) 결과에서도 합성목재가 적송 및 방부목에 비해 높게 나타났다.

FRP 복합재의 시험조건 변화에 따른 연기 위해성 평가 (Smoke Density Characteristics of the FRP to the variance of test method, resin type and specimen shape)

  • 이덕희;정우성;김용기;김선옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.567-571
    • /
    • 2002
  • In this study we reported the Smoke Density test method of interior panel of railroad passenger car and investigated the specific smoke density(Ds) by NBS smoke chamber to the variance of some test conditions. First we compared the result of Ds from ISO 5659-2 with that from ASTM E662 for same phenol FRP Secondary studied the Ds value to the variance of resin type and to the variance of specimen shape.

  • PDF

철도차량 시트재료의 개별 및 조립체 시험에 대한 연기특성 비교 (Smoke density comparison for composite and single materials of train seat)

  • 이은경;이덕희;조희기;이철규;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2006
  • Due to the damage which is caused by with the smoke, in the analysis statistics of a fire accident smoke is becoming the important evaluation index of fire quality. We must follow the procedures to use interior material for railway car as stated the Safety regulation for the urban railway car. In this study, we compared the Smoke Density of the train seat by test between Cone-Calorimeter and Smoke Density-Chamber. The results showed that the smoke density by test between Cone-Calorimeter and Smoke Density-Chamber is visible a similar tendency.

  • PDF

시험조건 변화에 따른 연기밀도 특성 조사 (Smoke Density Values to the variance of test conditions)

  • 이덕희;이철규;정우성;김선옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.339-345
    • /
    • 2004
  • In this study we reported the Smoke Density values of interior materials of railroad passenger car and investigated the specific smoke density(Ds) by NBS smoke chamber to the variance of some test conditions. First we compared the result of Ds from ISO 5659-2 with that from ASTM E 662 for same material. Secondary studied the Ds value to the variance of specimen shape and thickness and to the variance of other conditions.

  • PDF

페놀 폼 단열재의 연기밀도 및 가스유해성 평가 (Evaluation of Smoke Density and Noxious Gas for Phenol Foam Insulation)

  • 박형주
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.38-43
    • /
    • 2010
  • The smoke density and noxious gas for phenol foam and polyurethane foam were measured according to test methods in ASTM E 662 and KS F 2271. It was observed that phenol foam had the possibility of application for sandwich panel and board compared with polyurethane foam. In the experimental results, phenol foam showed comparatively excellent property than polyurethane foam in smoke density and noxious gas. The polyurethane foam showed comparatively high smoke density and didn't meet the evaluation standard of noxious gas in KS F 2271. From the experimental results of smoke density and noxious gas, it can be said that phenol foam has both comparatively good safety and high possibility of application than polyurethane foam in the building fire of sandwich panel structure because of lower smoke density and noxious gas.

방염도료의 방염성능 및 발연특성에 관한 연구 (A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint)

  • 김황진;이성은;오규형
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.78-83
    • /
    • 2009
  • 방염도료의 주성분 및 특성에 따른 방염성능과 발연특성에 대하여 알아보기 위하여 국내에 유통되어지는 17종의 방염도료를 MDF에 방염처리하여 45도 연소실험과 연기밀도실험을 실시하였다. 45도 연소실험 결과 주성분별로는 아크릴 수지를 주성분으로 한 방염도료의 방염성능이 가장 우수한 것으로 평가되어지며 유성방염도료 보다는 수성방염도료의 방염성능이 우수한 것으로 나타났고 또한 무광방염도료보다 유광방염도료의 방염성능이 더 우수한 것으로 평가되었다. 연기밀도실험을 통한 발연특성은 아크릴 수지를 주성분으로 한 시료에서 연기밀도가 상대적으로 낮게 측정되었으며 특성별로는 수성방염도료를 처리한 시료들에서 유성방염도료를 칠한 시료보다 연기밀도가 낮게 측정되었다.

터널내 화재시 PIV를 이용한 연기제어 특성에 관한 연구 (A Study on the Characteristics of Smoke Control using PIV in Tunnel Fires)

  • 고재웅;김종윤;서태범;임경범;이동호
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.6-11
    • /
    • 2006
  • This study aims to measure a smoke density and velocity by using the PIV method in case a fire occurs in tunnels. By doing so, this will estimate a critical velocity, examine its appropriateness, and present the basic materials necessary for designing a smoke control equipment. For this study, a visualization test was conducted based on the 1/20 miniature of a real tunnel according to the Froude scaling. As a part of basic experiments, a correlation between smoke density and brightness was analyzed here, and a critical velocity was estimated on the condition that a fire breaks out in tunnels. As a result, this study finds that there is a correlation between smoke density and brightness within a range of 100% to 30% transmittance, from which a quantitative smoke density can be obtained. The study also suggests that a critical velocity calculated from the Kennedy formula shows about 10% difference from that estimated in the test.

자동차 내장재의 연소 특성에 관한 연구 (A Study on the Characteristics of Combustion for Car Interior Materials)

  • 김영탁;김해림;박영주;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.450-455
    • /
    • 2008
  • We have carried out the test using the cone calorimeter and the smoke density chamber to evaluate the characteristics of the combustion for the car interior materials passed horizontal burning test. We have analysed many parameters related to fire hazard. These parameters are the ignition time, the heat release rate, the maximum average rate of heat emission, the flashover propensity and specific optical density. There was a significant difference in HRR and optical smoke density. The HRR was $185{\sim}446kW/m^2$ and optical smoke density was $119{\sim}1207$. Only horizontal burning test was performed to evaluate the fire hazard for the car interior materials.

  • PDF