• Title/Summary/Keyword: Smoke control

Search Result 546, Processing Time 0.031 seconds

A Study on the Efficiency of Smoke Barriers in the Subway Station (지하역사 제연경계벽의 제연 효용성에 관한 연구)

  • Kim, Bum-Kyu;Kim, Hee-Young;Lee, Sung-Mi;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.204-208
    • /
    • 2008
  • Casualties Damage from Smoke is very serious consequence. Especially, Damage from smoke in in the Subway Station is the terrible result. Smoke from the fire in the Subway Station that evacuation route on the path and the sight of refugees caused by serious traffic problems. Accordingly, A study on Smoke barriers of smoke systems take into considerations relate to effects depending on wind velocity speed of the piston effect come into the retarding effect of smoke control in smoke barriers. As a result of modeling, According to increasing of Velocity in the platform which installed smoke barriers were been on the increase spreading quantity of smoke in the right direction of upstairs however, In contrast spreading quantity of smoke in the left direction on the upstairs were been on the decrease.

  • PDF

Design for Pressurizing System about Vestibule by Stack Effect & Engineering Analysis - Focused on Case Study - (굴뚝효과와 공학적분석에 의한 부속실 가압시스템 설계 - 사례를 중심으로 -)

  • Kim, Yong-Kwang
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.145-153
    • /
    • 2009
  • We are generally applicate smoke control only vestibule about special escape staircase, it is one of some smoke control model of NFSC 501A. But there are some point at issue in this system. The smoke control system on supervision field of writer is smoke control only vestibule same as the other resemble field. Writer studied in the concrete to find a solution at this issue, and derived a conclusion the most reasonable system on the field is "same time smoke control for staircase and vestibule" by the engineering analysis considering stack effect.

A Study on the Historical Comparative of Smoke Control for Fire Safety Law and Building Law (국내의 연기제어 관련 소방법과 건축법의 변천과정에 관한 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.97-98
    • /
    • 2017
  • These days the buildings are getting higher, bigger, and in a deep. According to that, it was the Large-Scale casuality by smoke from Daeyeongak Hotel fire in 1971 to Uijeongbu apartment fire in 2015, and the law of smoke control has consistently changed. but the analysis for improving the law isn't working. Therefore on this study, it conducts the analysis of historical comparative about smoke control and it will present the basic data for improving the law of smoke control and in-depth analysis.

  • PDF

A Study on Appropriateness of Performance Criteria of Smoke Control System for Underground Spaces (I) (지하공간에 대한 제연설비 성능기준의 적정성 고찰(I))

  • Ahn, Chan-Sol;Kim, Heung-Youl;Yoo, Yong-Ho;Jeon, Gyu-Yeop
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.103-106
    • /
    • 2008
  • This study is intended to evaluate the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings (중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구)

  • Min, Se Hong;Lee, Jae Moon;Bae, Yeon Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

A Study on the Automatic Pressure Differential Sensor Development of Smoke Control Zone (제연구역의 자동 차압센서 개발에 관한 연구)

  • Lee, Dong-Myung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.23-28
    • /
    • 2005
  • This study defined engineering mechanism and compensation method to establish reference pressure of smoke control zone with atmospheric pressure that is compensated for temperature. The reliable pressure differential sensor was developed by establishing the specifications, algorithms and constructing engineering data. The development of pressure differential sensor can cut down number of processes, manufacturing and installation cost by removing pressure measurement pipe established separately for non smoke control zone, and improve the accuracy of pressure differential by embedding pressure measurement ports for non smoke control zone. More correct and reliable pressure differentials can be obtained by the central control rather than the existent individual control. This will provide the basics and the flexibility to the integral smoke control system and accordingly improve the performance of disaster prevention.

A Study on the Smoke Control Performance Evaluation of High-rise Buildings under Smokeproof Enclosure Design Scenarios (초고층 건축물의 수직 구획화에 따른 급기가압제연시스템 성능평가에 관한 연구)

  • Bae, Sang-Hwan;Ryu, Hyung-Kyou;Lee, Byung-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.343-350
    • /
    • 2014
  • Regardless of the building design scenarios, evaluation of high-rise buildings required to have smoke-proof enclosures that are provided with a smoke management system. The goal of the smoke management system design is to make sure the pressure differentials at every story within the building fall within the allowable pressure range. If the minimum design pressure is not met, smoke may enter the stair. If the provided pressure is too great, it becomes difficult for occupants to open the doors, while attempting to egress. Ensuring that the pressure differential between the vestibule and the floor is within the prescribed range becomes challenging, due to natural effects on the building, such as the stack effect. In this research, smokeproof enclosure design scenarios were evaluated; and as a result, separation levels for compartmentation were deduced, in the balancing of pressurized-vestibule smoke control systems.

A Study on the Comparison of Natural Ventilation Standards for Domestic and Foreign Logistics Warehouses (국내외 물류창고의 자연배연기준 비교에 관한 연구)

  • Kim, Yun-Seong;Choi, Yun-Ju;Huh, Ye-Rim;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.67-68
    • /
    • 2022
  • Foreign countries stipulate that ventilation and smoke control facilities are installed in logistics warehouses. On the other hand, in Korea, the design guidelines and standards of ventilation and smoke control facilities for logistics warehouses are not clear even in the situation where the number of human casualties caused by smoke has increased until recently. Accordingly, the smoke descent time according to the vent was calculated. As a result, when there was no vent, the smoke descent time was 369s. On the other hand, when the vent was installed, smoke did not fall because the amount of smoke was greater than the amount of smoke generated.

  • PDF

A Study on Heat and Smoke Exhaust Characteristics from the Subway Fire for Different Ventilation Modes (지하철 화재시 제연모드에 따른 열 및 연기 배출 특성 연구)

  • Chang, Hee-Chul;Yoon, Kyung-Beom;Park, Won-Hee;Kim, Tae-Kuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.37-42
    • /
    • 2008
  • This study is focused on the numerical predictions for different smoke-control ventilation modes for the subway fire. Smoke-control ventilation mode in the domestic platform is that exhausting for the smoke detected zones while supplying air or stopping any ventilation for other zones in the platform. Three cases of smoke control ventilation modes are considered. First and second case are present running smoke control mode in Korea. The third is that smoke-control ventilation fans equipped in the platform are operated in first 4 minute(platform evacuation time, NFPA130) since then the fans equipped in the platform are stopped and the fans equipped in the tunnels are operated. Distributions of heat, carbon monoxide and visible range are compared at a height of 1.7m(passenger breath/sight height) above the platform. The numerical results show that air supply fan operation in the platform causes the smoke disturbance and a rapid spread of the smoke. The switch-operation with fans in both the platform and tunnel are better than operation with only platform fans in smoke rejection efficiency.

A Study on the Smoke Control in Pressure Differential Systems (급기가압 제연댐퍼 위치에 따른 방연풍속특성 및 성능개선방안에 관한 연구)

  • Bae, Sang-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.239-244
    • /
    • 2011
  • This study is aimed to develop fundamental technology on the smoke control method by simulation model and scale model simulation technique in pressure differential systems. Thereby, this research aimed to establish design elements and technologies required for smoke control system that is suitable to pressure differential systems of the high-rise buildings in order to minimize the loss of lives and property damage in case of fire.

  • PDF