A Study on Fire Features of Double-Skin Facade Structure by Using Fire Simulation (FDS) (화재 시뮬레이션(FDS)을 이용한 이중외피 구조의 화재 특성에 관한 연구)

  • Gu, Seon-Hwan;Kim, Hyun-Ho;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This study aims to address the fire characteristics of Double-skin facade using the Fire Dynamics Simulator (FDS). To end this, Double-skin facade was classified into the four structures, that is Box, Shaft-box, Corridor, Multistory, through PyroSim program which was based on FDS, and further each structure of fire characteristics were analyzed numerically as well as comparatively in the current study. This study also examined smoke movement, smoke density, smoke detectors, and visibility in order to closely identify the each structure of fire characteristics. The results of the study discovered that the Box structure did not significantly affect smoke which was rising in the other rooms, except for the fire room whereas the Corridor structure had positive effects on Double-skin facade horizontally. In addition, the Shaft-box structure showed the fastest vertical movement by means of the shaft, on the other hand, rising smoke influenced the other rooms as well. The Multistory structure along with rising smoke had a great impact on the other divided rooms in a vertical way.

Effect of Elementary Students' Understandings about Principle of Land and Sea Breeze Using Incense Smoke on the outside of Convection Current Box as a Scaffold in Convection Current Box Experiment (대류상자 밖의 향 연기 이동을 비계로 활용한 대류상자 실험이 초등학생들의 해륙풍의 원리 이해에 미치는 효과)

  • Kang, Wonmi;Shin, Aekyung;Hyun, Donggeul;Chae, Donghyun
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.3
    • /
    • pp.387-398
    • /
    • 2015
  • The purposes of this study were to analyze the effect of a scaffold to help in understanding the principle of land and sea breeze through the convection current box experiment and to analyze the students' inference abilities and analogy abilities. For this purpose, the 60 elementary students who had not learned the principle of land and sea breeze were surveyed and analyzed. When using the scaffold to compare the movement of the incense smoke in the convection current box with that of the incense smoke on the outside of the convection current box, the rate of the students who correctly understood the principle of the land and sea breeze between the sea and the land was very low. The result shows that the scaffold used in this study do not help sufficiently in understanding the principle of the land and sea breeze through analogy and it is necessary to introduce a new scaffold for the elementary students to understand it.

A Study of Obscuration on Height of Air Supply in Indoor Fire (옥내화재시 급기구의 높이에 따른 암흑화에 관한 연구)

  • 이창섭
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2001
  • This paper examined the variation in obscuration with height at indoor fire. The experiments were performed using a smoke box which is made for this job. It was found that the degree of smoke obscuration is depending upon the height. The obscurity at low position is less than that of high position. But there exist the deviation of obscurity at the position of air supply height.

  • PDF

Fundamental Study on Algorithm Development for Prediction of Smoke Spread Distance Based on Deep Learning (딥러닝 기반의 연기 확산거리 예측을 위한 알고리즘 개발 기초연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.22-28
    • /
    • 2021
  • This is a basic study on the development of deep learning-based algorithms to detect smoke before the smoke detector operates in the event of a ship fire, analyze and utilize the detected data, and support fire suppression and evacuation activities by predicting the spread of smoke before it spreads to remote areas. Proposed algorithms were reviewed in accordance with the following procedures. As a first step, smoke images obtained through fire simulation were applied to the YOLO (You Only Look Once) model, which is a deep learning-based object detection algorithm. The mean average precision (mAP) of the trained YOLO model was measured to be 98.71%, and smoke was detected at a processing speed of 9 frames per second (FPS). The second step was to estimate the spread of smoke using the coordinates of the boundary box, from which was utilized to extract the smoke geometry from YOLO. This smoke geometry was then applied to the time series prediction algorithm, long short-term memory (LSTM). As a result, smoke spread data obtained from the coordinates of the boundary box between the estimated fire occurrence and 30 s were entered into the LSTM learning model to predict smoke spread data from 31 s to 90 s in the smoke image of a fast fire obtained from fire simulation. The average square root error between the estimated spread of smoke and its predicted value was 2.74.

A Smoke Segmentation Detection Method on U-net (U-net을 활용한 연기 Segmentation 탐지 기법)

  • Gwak, K.M.;DUONG, THUY TRANG;Rho, Young J.
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.81-83
    • /
    • 2021
  • 4차 산업 혁명과 함께 인공지능이 발전 하고 있다. 그 CNN 등 과 같은 이미지 관련 신경망들이 발전되어 가스 탐지와 같은 여러 분야에서 사용되고 있다. 하지만 가스 탐지는 Box 형태의 탐지가 일반적이고 Segmentation에 관한 연구는 있지만 연기와 같이 경계선이 불분명한 개체에 대해서는 연구가 미비하다. 본 논문에서는 Segmentation에 강력한 성능을 보이는 U-net을 활용하여 Box 형태가 아닌 Segmentation을 진행하여 픽셀단위로 연기를 탐지하고자 한다.

  • PDF

Statistical Evaluation of Smoke Analysis Technique through Asia Collaborative Study V.

  • Ra, Do-Young;Rhee, Moon-Soo;Kim, Yoon-Dong;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.108-114
    • /
    • 1998
  • This study was conducted to evaluate the techniques or analyzing tobacco smoke by statistical treatment method for the analytical data through Asia Collaborative Study V. In addition to five smoke components analysis, consisting of TPM, water, nicotine, NFDPM, and puff count of four cigarettes samples, statistical parameters such as mean, standard deviation, box-and-whisker plots, h plots, k plots, regression coefficients, reproducibility (R), and repeatability (r) were also calculated. Analysis of water content of cigarette smoke was the most difficult task, whereas puff count analysis was the easiest as well recognized by all laboratories. Analysis of nicotine and puff count accounted for both the lowest and the highest variation among four parameters. The water coefficients indicated more randomness or variation in the slops. The NFDPM data exhibited both types of deviations from linearity. Water content of sample D indicated the highest difference between two single results and between two interlaboratory test results. As a whole, KGTRI ranked higher in the analytical techniques for statistical evaluation of results when compared with the practices of 28 other laboratories.

  • PDF

A Study on Redesign and Utilization of a Convective Circulation Box for Observations of Land and Sea Breezes (해륙풍 원리 이해를 위한 대류상자 재설계와 활용에 관한 연구)

  • Yang, Mi-Seon;Yun, Sung-Hyo
    • Journal of the Korean earth science society
    • /
    • v.31 no.3
    • /
    • pp.246-258
    • /
    • 2010
  • A convective circulation box was redesigned after analyzing reasons why adolescent elementary school students could not derive a convective circulation concept from the convection circulation box experiments. Even though students were in the formal operational period of Piaget, the adolescents felt difficult to understand a concept of the natural phenomena they have never seen before. Thus, we designed a method to help students increase their scientific understandings about the concept through developing a miniature convective circulation box. Findings indicated that an application of redesigned convective circulation box in the classroom experiment significantly increased the students' understanding about the convective circulations of land and sea breezes, and as well as their participation in the activities. In addition, the redesigned convective circulation box motivated students to develop their scientific thinking skills by allowing them to decide where to put visible incenses inside the box and to directly observe the smoke currents circulation formed accordingly. Redesigning and using a convective circulationbox as a miniature of natural phenomenon helps students avoid having misconceptions. The biggest merits of the box are that it is observable in all directions, it provides much clearer convective circulations comparing to the extant box, and it requires low production costs.

A Study on Fire Detection in Ship Engine Rooms Using Convolutional Neural Network (합성곱 신경망을 이용한 선박 기관실에서의 화재 검출에 관한 연구)

  • Park, Kyung-Min;Bae, Cherl-O
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.476-481
    • /
    • 2019
  • Early detection of fire is an important measure for minimizing the loss of life and property damage. However, fire and smoke need to be simultaneously detected. In this context, numerous studies have been conducted on image-based fire detection. Conventional fire detection methods are compute-intensive and comprise several algorithms for extracting the flame and smoke characteristics. Hence, deep learning algorithms and convolution neural networks can be alternatively employed for fire detection. In this study, recorded image data of fire in a ship engine room were analyzed. The flame and smoke characteristics were extracted from the outer box, and the YOLO (You Only Look Once) convolutional neural network algorithm was subsequently employed for learning and testing. Experimental results were evaluated with respect to three attributes, namely detection rate, error rate, and accuracy. The respective values of detection rate, error rate, and accuracy are found to be 0.994, 0.011, and 0.998 for the flame, 0.978, 0.021, and 0.978 for the smoke, and the calculation time is found to be 0.009 s.

Research on Improving the Performance of YOLO-Based Object Detection Models for Smoke and Flames from Different Materials (다양한 재료에서 발생되는 연기 및 불꽃에 대한 YOLO 기반 객체 탐지 모델 성능 개선에 관한 연구 )

  • Heejun Kwon;Bohee Lee;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.261-273
    • /
    • 2024
  • This paper is an experimental study on the improvement of smoke and flame detection from different materials with YOLO. For the study, images of fires occurring in various materials were collected through an open dataset, and experiments were conducted by changing the main factors affecting the performance of the fire object detection model, such as the bounding box, polygon, and data augmentation of the collected image open dataset during data preprocessing. To evaluate the model performance, we calculated the values of precision, recall, F1Score, mAP, and FPS for each condition, and compared the performance of each model based on these values. We also analyzed the changes in model performance due to the data preprocessing method to derive the conditions that have the greatest impact on improving the performance of the fire object detection model. The experimental results showed that for the fire object detection model using the YOLOv5s6.0 model, data augmentation that can change the color of the flame, such as saturation, brightness, and exposure, is most effective in improving the performance of the fire object detection model. The real-time fire object detection model developed in this study can be applied to equipment such as existing CCTV, and it is believed that it can contribute to minimizing fire damage by enabling early detection of fires occurring in various materials.

Comparison between a Light-Scattering and a Light-Extinction Methods for the Study on Soot Yielding Characteristics of an Electric Cable Fire (전선 매연 생성 특성 연구를 위한 광산란법-광소멸법의 비교)

  • Cho, Sang-Moon;Lee, Min-Jung;Kim, Nam-Il
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.38-43
    • /
    • 2008
  • Significant portion of the fire accident is caused by some troubles in electric circuits. To prevent the fire induced by those electric trouble, some indications of electric fire need to be suitably detected at the first stage of the fire development. With this background, the characteristics of soot yielding of electric cables have been investigated using a light extinction method. In this study, a light scattering method was compared with the light extinction method. A slot-type premixed-flame combustor was traversed to bum three types of electric cables by compulsion, then the mass decrease rate and the soot densities were measured. According to the experimental results, the light scattering method is preferred to the light extinction method when the soot yield ratio is relatively small. Thus the former method is more suitable to detect the occurrence of an electric fire in a power distributer box.