• Title/Summary/Keyword: Smoke behavior

Search Result 222, Processing Time 0.027 seconds

Simulation of smoke movement in a ventilated tunnel by using fine hydrogen bubbles (미세수소기포를 이용한 환기 터널내의 연기거동 모사)

  • Park, Won-Hee;Lee, Han-Su;Jang, Yong-Jun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1768-1772
    • /
    • 2008
  • The authors previously presented that the experimental technique using fine bubbles generated by electrolysis simulated fire behavior in a tunnel. We improve this experimental setup to enable this to be considered tunnel-ventilation by circulation of salt water. In this paper we introduce the new experimental setup and the visualization of fine hydrogen bubbles simulated smoke in a ventilated tunnel by using a laser sheet are presented.

  • PDF

Turbulent Dispersion Behavior of a Jet Issued into Thermally Stratified Cross Flows(I) (열적으로 성층화된 횡단류에 분출된 제트의 난류확산 거동(I))

  • Kim, Kyung Chun;Kim, Sang Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.218-225
    • /
    • 1999
  • Flow visualization study has been conducted to simulate the turbulent dispersion behavior of a crossflow jet physically under the conditions of various thermal stratification in a wind tunnel. A smoke jet with the constant ratio of the jet to freestream velocity is injected normally to the cross flow of the thermally stratified wind tunnel(TSWT) for flow visualization. The typical natures of the smoke dispersion under different thermal stratifications such as neutral, weakly stable, strongly stable, weakly unstable, strongly unstable and inversion layer are successfully reproduced in the TSWT. The Instantaneous velocity and temperature fluctuations are measured by using a cold and hot-wire combination probe. The time averaged dispersion behaviors, the centerline trajectories, the spreading angles and the virtual origins of the cross jet are deduced from the edge detected images with respect to the stability parameter. All the general characteristics of the turbulent dispersion behavior reveal that the definitely different dispersion mechanisms are inherent in both stable and unstable conditions. It is conjectured that the turbulent statistics obtained in the various stability conditions quantitatively demonstrate the vertical scalar flux plays a key role in the turbulent dispersion behavior.

A Simulation Study on Fire Behavior in The Wide Gangway Train (광폭 갱웨이 전동차량내 화재거동에 대한 수치해석적 연구)

  • Kim, Chi-Hun;Lee, Duck-Hee;Kim, Dong-Woon;Jung, Woo-Sung;Park, Seo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.177-182
    • /
    • 2010
  • The wide gangway train have different indoor without the gate door to the most trains. in gangway train of structure without the section, heavy casualties are possible to occur by quite smoke movement in fire. in this study, fire behavior and smoke movement were analyzed as the locations and kinds of fire source by using FDS simulation tool. the model train size of $9m{\times}2.4m{\times}2.4m$ was serially constructed of six cars.

  • PDF

Numerical Simulation on the Heat and Smoke Flow Phenomena Due to the Fire in a Cyclodrome (경륜장 내부의 화재발생에 따른 열 및 연기 거동에 대한 수치적 연구)

  • 박원희;김태국;손봉세
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, numerical calculations are conducted to predict the characteristics of the heat transfer and smoke propagation in a cydodrome. The gas flow velocity and temperature around the origin of the fire is obtained by using a plume model and the turbulent flow characteristics are considered by standard $textsc{k}$-$\varepsilon$ turbulent model. In this study, the transient thermal behavior can be used for designing fire detection of large rooms.

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Policy Compliance and Smoking related Behavior Change in a Smoke-free Apartment (금연 공동주택 주민들의 정책 순응도와 흡연 관련 행태 변화)

  • Cho, Hoosun;Kim, Eunsu;Nam, Hae-Sung
    • Journal of agricultural medicine and community health
    • /
    • v.45 no.4
    • /
    • pp.221-234
    • /
    • 2020
  • Objectives: The purpose of this study is to identify the policy compliance according to the socio-demographic characteristics, stress, satisfaction of relationship, Health Belief Model and characteristics of smoking behaviors and knowledge related smoking of the residents living in the Smoke-free apartment and to investigate the change of the smoking related behavior before and after the implementation of the policy. Methods: The subjects of the survey were 293 residents aged 19 or older who reside in apartments six months after the designation of Smoke-free apartment located in Daejeon. All collected data were analyzed using T-test, ANOVA and Hierarchical multiple regression of SPSS for windows(ver 24.0) program. Results: The policy compliance was higher in women and those who lived for less than two years, and non-smokers were significantly higher. The policy compliance of the whole subjects was related to satisfaction with the surrounding relationship, perceived disability about smoking cessation, frequency of smoking and the amount of smoking. The policy compliance of the whole subjects was related to the satisfaction of the surrounding relationship, the perceived disability about smoking cessation, and the amount of smoking. In addition, after the implementation of the gold research station designation policy, it had a positive impact on smoker's smoking behavior and resulted in reducing the frequency of secondhand smoke among residents. Conclusions: In order to increase the compliance of the non-smoking policy It is necessary to continuously expand the indoor smoking cessation zone policy, develop policies and supplement the health belief model components.

The Risk Assessment of Tunnel Fire Through Real Scale Fire Test (실물터널 화재실험을 통한 터널화재 위험도 평가)

  • 최준석;최병일;김명배;한용식;장용재;이유환;황낙순;김필영
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2002
  • The real scale tunnel fire tests are carried out for the first time in domestic range to assess the extent of risk in the tunnel fire. The tunnel dimension is 465 m in length, 9.2 m in width and 6.5 m in height. Gasoline pools with 0.25 MW∼2.5 MW size and a 1500CC passenger car are used as fire sources. Six jet fans are used to change the flow velocity inside the tunnel. Temperatures at total 86 points in the tunnel are measured to find the temperature distribution and smoke behavior in the real tunnel fire. In the experiment, it is examined that the important parameters to assess the extent of risk in tunnel fire such as back layering of smoke front, descending of smoke layer and the fire size of a real passenger car.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

A Transitional Behavior of a Premixed Flame and a Triple Flame in a Lifted Flame(II) (부상화염에서 예혼합화염과 삼지화염의 천이적 거동(II))

  • Jang Jun Young;Kim Tae Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.376-383
    • /
    • 2005
  • In the paper we investigate characteristics of a transitional behavior from a premixed flame to a triple flame in a lifted flame according to the change of equivalence ratio. In previous study, we showed that the stabilized laminar lifted flame regime is categorized by regimes of premixed flame, triple flame and critical flame. A gas-chromatograph is used to measure concentration field, a smoke-wire system is used to measure streak line, and a PIV system is used to measure velocity field in lifted flame. In the visualization experiment of smoke wire, the flow divergence and redirection reappeared in premixed flame as well as triple flame. Thus we cannot express the flame front of lifted flame has a behavior of triple flame with only flow divergence and redirection. In PIV measurement, flow velocity for those three flames has minimum value at the tip of flame front. To differentiate triple flame and premixed flame, $\Phi$ value of partially premixed fraction is employed. The partially premixed fraction $\Phi$ was constant in premixed flame. In critical flame small gradient appears over the whole regime. In triple flame, typical diffusion flame shape is obtained as parabolic distribution type due to diffusion flame trailing.