설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구 (A numerical study on effects of thermal buoyance force on number of jet fans for smoke control)

  • 유지오;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제15권3호
    • /
    • pp.301-310
    • /
    • 2013
  • 현재 도로터널에는 화재시 임계풍속을 유지할 수 있도록 제트팬을 설치하고 있으며, 제트팬 댓수는 임계풍속을 유지하기 위한 유동저항, 자연풍에 의한 환기저항, 열부력에 의한 환기저항을 고려하여 산정한다. 그러나, 국내의 경우, 제트팬 댓수 산정시 열부력은 고려하지 않고 있는 실정이다. 이에 본 연구에서는 열부력이 제트팬 댓수에 미치는 영향을 검토하기 위해서 터널연장(500, 750, 1000, 1500, 2000, 3500 m) 및 경사도(-1.0, -1.5, -2.0%)를 변수로 하여 화재성장곡선에 따른 비정상상태의 수치 시뮬레이션을 수행하였으며, 열기류의 평균온도 및 열부력에 의한 압력손실을 검토하여 열부력이 제트팬 댓수에 미치는 영향을 검토하였다. 이에 본 연구에서는 화재로 인한 열부력을 고려하는 경우에 제트팬 댓수의 증가가 필요하며, 특히, 설계화재강도를 100 MW로 하는 경우에는 본 해석조건의 모든 범위에서 열부력에 의한 압력손실이 차량저항에 의한 압력손실의 최대치보다 증가하며, 현행설계기준을 적용하는 경우보다. 최소 2~11대의 제트팬 대수의 증가가 필요한 것으로 분석되었다. 따라서 제연용 제트팬 용량 산정시 열부력에 대한 고려가 반드시 필요한 것으로 나타났다.

공연장 무대부 화재 시 자연배출구 및 방화막 영향 검토를 위한 축소모형 실험 (Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage)

  • 백선아;양지현;정찬석;이치영;김동균
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.41-49
    • /
    • 2019
  • 본 연구에서는 실존하는 공연장을 대상으로 1/14 비율로 축소하여 제작한 모형을 이용하여 공연장 무대부 화재 시 자연배출구 및 방화막 영향을 검토하였다. 자연배출구가 개방되고 방화막이 미설치된 경우에 무대부 온도가 낮은 것으로 나타난 반면, 객석부 온도의 경우 자연배출구가 개방되고 방화막이 설치된 경우에 낮은 것으로 측정되었다. 한편, 객석부 프로시니엄 개구부에 근접한 위치에서의 온도 상승 시점 분석을 통해 자연배출구 개방이 무대부에서 객석부로의 연기 유출 시작 시점을 지연시키고 객석부 온도 상승을 억제할 가능성이 있음을 확인하였다. 본 실험 조건에서 방화막 설치 여부는 자연배출구를 통한 유출 유동의 속도 및 질량 유량에 큰 영향을 미치지 않았는데, 이는 무대부에 존재하는 개구부 때문으로 판단된다. 본 실험 결과는 실제 공연장 화재 시 자연배출구 및 방화막 영향 평가를 위한 기초 데이터로 활용 가능할 뿐 아니라 전산시뮬레이션의 신뢰성 검증을 위한 자료로 이용될 수 있을 것으로 판단된다.

천장개구부를 갖는 정사각형 밀폐공간내의 자연대류-복사 열전달에 관한 연구 (A Study on the natural Convection and Radiation in a Rectangular Enclosure with Ceiling Vent)

  • 박찬국;추병길;김철;정재환
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.28-39
    • /
    • 1998
  • 본 연구에서는 $20\%$ 천장개구부가 있는 정사각형 밀폐공간내의 순수자연대류와 자연대류 -복사가 고려된 복합열전달을 순차해석과 실험을 통하여 비교 분석하였다. 수치해석은 순수자연대류에 대하여 SIMPLE 알고리즘을 사용하였고, 복사열전달에 대해서는 S-N 구분 종좌표법을 이용하였으며 난류유동의 경계조건은 벽함수를 적용하였다. 실험은 수치해석의 결과와 비교하기 위하여 동일한 조건에 대하여 수행되었다. 그 결과 순수자연대류와 복합열전달의 유동장, 온도장의 형상은 유사한 유선함수를 보이고 있으며, 유동가시화를 통한 실험결과와 잘 일치하고 있음을 보여준다. 수치해석과 실험의 온도분포를 비교한 결과 평균 $8.5\%$의 오차를 보였다.