• 제목/요약/키워드: Smoke Concentration

검색결과 275건 처리시간 0.023초

원료엽 및 그 배합비율에 따른 부류연중의 니코틴, 탈, 일산화탄소 함량 변화 (Changes of Nicotine, Tar, and CO Concentration in the Sidestream Smoke by Tobacco Leaves and Their Combinations)

  • 황건중;이문수;나도영
    • 한국연초학회지
    • /
    • 제21권2호
    • /
    • pp.128-135
    • /
    • 1999
  • This study was conducted to determine the sidestream smoke concentration, nicotine, tar, and CO, by the characteristics of tobacco leaves and their combinations. 20 kinds of tobacco leaves and 15 types of their combinations were selected for this study. After collecting the sidestream smoke by fishtail chimney, the concentrations of nicotine, tar, and CO in sidestream smoke were analyzed. Variation in nicotine concentration of sidestream smoke among tobacco leaves and their combinations was as much as 9-times. Heavy leaves and burley leaves were higher in nicotine concentration than light leaves and flue-cured leaves, respectively, the reconstituted tobacco leaf had the minimum concentration of nicotine. Tar concentration of sidestream smoke also was changed by the characteristics of tobacco leaves and their combinations. As the american C4F had the maximum concentration of tar in sidestream smoke, the reconstituted tobacco leaf showed the minimum concentration. Blending 50 % flue-cured B1-0 plus 50% burley B1-T grade showed the highest value in the nicotine concentration. Also, in case of adding B3K and izmir tobacco leaves, the nicotine concentration was decreased. The tar concentration in the sidestream smoke increased as increasing the amount of flue-cured heavy leaf. The CO concentration was not so much Changed by the characteristics of tobacco leaves and their combinations.

  • PDF

국내 원료잎담배의 착엽위치 및 가공등급에 따른 연기성분 변화 (Changes of Smoke Components with Stalk Position and Grade of Korean Leaf Tobacco)

  • 황건중;이문수
    • 한국연초학회지
    • /
    • 제24권1호
    • /
    • pp.38-45
    • /
    • 2002
  • This study was conducted to determine the smoke component concentration and the smoke distribution in the cambridge filter pad and cigarette filter with stalk position and grade of Korean leaf tobaccos. 12 grades of flue-cured and burley leaf tobaccos which were taken from the Kim-cheon and Ock-cheon leaf tobacco processing factory were used for this study. Six kinds of smoke components such as tar, nicotine, water, carbon monoxide(CO), carbon dioxide($CO_2$) puff No. collected in the cambridge filter pad and cigarette filter were analyzed. Also, nicotine/tar, CO/tar ratio were calculated from the analytical data. Puff no., CO, and $CO_2$ concentration of flue-cured and burley tobacco leaves at high stalk position were higher than those of low stalk position, and these components were increased in high grade of leaf tobacco. Compared with flue-cured tobacco, burley tobacco showed a little values of puff no., nicotine, and tar concentration. The pH range of burley tobaccos was broader than that of flue-cured tobaccos, and the ammonia concentration of burley tobaccos was significantly higher than that of flue-cured tobaccos. The pH value and ammonia concentration of burley tobaccos were decreased as stalk position of leaf tobaccos decreased. The distribution of smoke components collected in the cambridge filter pad and cigarette filter was different with a different grade and stalk position of tobacco leaves. In high stalk position of tobacco leaves, the portion of smoke components collected in the cambridge filter pad was also increased. The average nicotine, water, and tar removal efficiency by a cigarette filter in a flue-cured tobacco were 37%, 64%, and 48%, respectively. Compared with flue-cured tobaccos, smoke components of burley tobaccos had high nicotine and low water removal efficiency by a cigarette filter. The average ratio of nicotine/tar and CO/tar of flue-cured tobaccos and burley tobaccos were 0.097, 1.22, 0.094, and 0.97, in order. Nicotine/tar ratio was decreased and CO/tar ratio was increased in low stalk position.

셀룰로오스 단열재의 연기발생에 관한 연구 (Studies of the Smoke Emission from Cellulose Fiber Insulation)

  • 김홍;강영구
    • 한국안전학회지
    • /
    • 제9권2호
    • /
    • pp.12-17
    • /
    • 1994
  • Smoke evolved from burning cellulose insulation treated with boric acid-borax-alum as combustion retardants has been studied using a light absorption method. It has been shown that the quantity of smoke are decreased with the increase of oxygen concentration. Applied fire retardants did not increase smoke generation from investigated cellulose insulation in range of themal degradation without flaming. These same fire retardants increased from in the range of flaming combustion. The results of this work have been analysed using imperical equation, which correlated the smoke density at oxygen content of combustion transition. This equation may be. $\sigma$=$\sigma$$_{T}$ exp{-7.24$\times$10$^{-7}$ ( $O_2$ $O_{2.T}$)}Where $O_2$is the concentration of oxygen in the oxidizing gas, and $O_{2.T}$ refers to oxygen concentration of combustion transition.n.n.n.

  • PDF

개구부와 열원의 위치에 따른 연기이동에 관한 연구 (A Study on the Smoke Movement by the Opening and Heat Generator Position)

  • 조성우;이재윤
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.7-14
    • /
    • 2002
  • 열원의 발열이 있는 작은 공간에서 상승기류에 의한 연기 확산의 특징에 대하여 조사하였다. 유입구와 유출구의 위치와 연기의 발생위치의 변화에 대한 3가지의 경우에 대하여 수치시뮬레이션을 이용하여 연기가 어떻게 확산되는가를 알아보았다. 좌측 상부에 유입구와 우측 하부에 유출구가 설치된 경우와 좌측 하부에 유입구, 우측 상부에 유출구가 설치된 경우는 기류속도, 공기온도 및 연기농도는 비슷한 분포를 나타냈다. 또한, 좌측 하부의 유입구와 우측 상부의 유출구인 경우 온도분포는 0∼0.3이고, 연기의 농도분포는 0.06∼0.14로 나타났다. 특히, 열원의 발열의 위치는 작은 실에 있어서 온도분포에는 영향을 미치지 않으나, 농도분포에는 영향을 미치는 것을 나타났다.

충돌분무에 의한 디젤기관의 배기 배출물 특성 (Characteristics of Exhaust Emission by Impinging Spray of Diesel Engine)

  • 진용수;김재동;김용복
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.26-31
    • /
    • 2007
  • Recently, study on the improvement of combustion performance for the diesel engine by using the impinging spray in the combustion chamber has been actively studied. The purpose of this study is to examine the variation of exhaust emission between the trial engine with impinging plate and the prototype engine in accordance with change of fuel injection timing and fuel injection pressure. The concentration of nitrogen oxide of trial engine decreased more than 50% compared to prototype engine. However, smoke of trial engine indicated very high concentration compared to prototype engine. The effect of fuel injection timing on the nitrogen oxide and smoke indicated different results, that is, the concentration of nitrogen oxide decreased as the degree of fuel injection start become slower, whereas the concentration of smoke decreased as the degree of fuel injection start become faster.

  • PDF

환경이 조절되는 Chamber 내에서 Environmental Tobacco Smoke의 생성과 감소 현상 (Generation and Decay Phenomena of Environmental Tobacco Smoke in Controlled Experimental Atmosphere Chamber)

  • 이문수;나도영;안기영;이규서
    • 한국연초학회지
    • /
    • 제18권2호
    • /
    • pp.170-176
    • /
    • 1996
  • This paper describes the generation and decay phenomena of gas, vapor and particulate phase components of environmental tobacco smoke in 18 m3 controlled experimental atmosphere chamber. Real time-weighted average concentration ratios of markers were determinated at no ventilation rates and sampling durations of starting to smoking 45 min. Average concentration of major ETS markers was no significant on the mainstream smoke contents of commercial cigarette and decay ratios were dependent on first order kinetic. RSP/nicotine, solanesol and 3-EP were good predictors of ETS concentration in the public indoor field. The concentration ratio of vapor phase and particulate phase components is highly variable to assessment of indoor air quality with ETS. Key words : ETS, chamber study, ETS markers.

  • PDF

4행정 중속 디젤기관의 스모크리스 시동 (Smokeless Starting for 4 Cycle Medium Speed Diesel Engine)

  • 정석호
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.

메탄올-디젤기관의 스모크 저감에 관한 연구 (A Study on the Smoke Reduction of Methanol-Diesel Engine)

  • 한성빈;문성수
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2421-2429
    • /
    • 1996
  • The objective of this research is to apply effect of the pre-mixed combustion quantity and smoke emission in diesel engine. According as air fuel ratio is increased, emission of smoke concentration is linearly reduced. As Injection timing is advanced, smoke concentration is remarkably reduced. It is considered to be the primary cause of the increase in the premixed combustible mixture during long ignition delay period with advancing injection timing. Smoke is increased with increasing engine speed, so it is considered to be the primary cause of the increase of the mass of fuel injected. Smoke is decreased according to the increase of methanol volume ratio. It is considered that the primary cause of the increase in the quantity of pre-mixed combustion.

디젤기관의 매연저감에 미치는 초음파 영향 (Effects of the Smoke Reduction of Diesel Engine Operated with Ultrasonically Reformed Fuel)

  • 이병오;김용국
    • 한국자동차공학회논문집
    • /
    • 제18권3호
    • /
    • pp.88-94
    • /
    • 2010
  • In this paper, the effect of the ultrasonic energy on the diesel engine's smoke reduction has been investigated for indirect injection diesel engine. The smoke concentration of the ultrasonically reformed diesel fuel was reduced remarkably in comparison with conventional diesel fuel. And in-cylinder pressure, heat release rate and mass fraction burned was improved but combustion duration was decreased. However, The combustion durations and the smoke concentrations of both diesel fuels were proportional to the increases of engine loads. Also, When the combustion duration has been increasing, the smoke emission has been augmenting in the shape of the exponential functions.

연기감지기의 내식시험에 관한 연구 (A Study on the Corrosion Resistance Test of Smoke Detectors)

  • 김형권;윤헌주;권성필;사공성호;백창선
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF