• Title/Summary/Keyword: Smith equivalent

Search Result 20, Processing Time 0.019 seconds

An Aerodynamic Performance Analysis of the Low-Speed Airfoils in Seperated Flow Field (박리유동장에서 저속 익형의 공기역학적 성능해석)

  • Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.153-168
    • /
    • 1995
  • The purpose of this study is to develop a method for predicting the aerodynamic performance of the subsonic airfoils in the 2-dimensional, steady and viscous flow. For this study, the airfoil geometry is specified by adopting the longest chord line system and by considering local surface curvature. In case of the inviscid-incompressible flow, the analysis is accomplished by the linearly varying strength vortex panel method and the Karman-Tsien correction law is applied for the inviscid-compressible flow analysis. The Goradia's integral method and the Truckenbrodt integral method are adopted for the boundary layer analysis of the laminar flow and the turbulent flow respectively. Viscous and inviscid solutions are converged by the Lockheed iterative calculating method using the equivalent airfoil geometry. And the analysis of the seperated flow is performed using the Dvorak and Maskew's method as the basic method. The wake effect is also considered and its geometry expressed by the formula of Summey & Smith when no seperation occurs. A computational efficiency is verified by the comparison of the computational results with experimental data and by the shorter execution time.

  • PDF

Equivalent Transformations of Undiscounted Nonhomogeneous Markov Decision Processes

  • Park, Yun-Sun
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.2
    • /
    • pp.131-144
    • /
    • 1992
  • Even though nonhomogeneous Markov Decision Processes subsume homogeneous Markov Decision Processes and are more practical in the real world, there are many results for them. In this paper we address the nonhomogeneous Markov Decision Process with objective to maximize average reward. By extending works of Ross [17] in the homogeneous case adopting the result of Bean and Smith [3] for the dicounted deterministic problem, we first transform the original problem into the discounted nonhomogeneous Markov Decision Process. Then, secondly, we transform into the discounted deterministic problem. This approach not only shows the interrelationships between various problems but also attacks the solution method of the undiscounted nohomogeneous Markov Decision Process.

  • PDF

A Change and Prediction of Biaxial Fatigue Life of Cast Duplex Stainless Steels by Degradation (2상 주조 스테인리스강의 열화로 인한 2축 피로수명의 변화와 예측)

  • Kwon, Jae-Do;Park, Joong-Cheul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.410-418
    • /
    • 2004
  • The multiaxial fatigue test under in-phase and out-of$.$phase load were performed to study what degradation phenomenon affects fatigue life with virgin and 3600 hrs degraded materials. The various kind of fatigue data fur fatigue life prediction were acquired under pure axial and pure torsional load of fully reversal condition. The models which was investigated are: 1) the von Mises equivalent strain range, 2) the critical shear plane approach method of Fatemi-Socie(FS) parameter, 3) the modified Smith-Watson-Topper(SWT) parameter. The result showed that, fatigue life by material degradation are decreased and life prediction which was used the FS parameter is not conservative but the best result.

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

A simple Q measurement method of a lossy coupled cavity resonator (손실결합 공동공진기의 간편한 Q 측정 방법)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.1015-1020
    • /
    • 2018
  • The cavity resonator is one of the widely used components in the microwave applications. The unloaded Q, the resonant frequency, and the coupling factor are basic parameters of a cavity. A simple unloaded Q factor measurement procedure of a cavity is proposed in a lossy coupling. The equivalent circuit of a cavity with coupling loss at near the resonant frequency is presented. The coupling loss resistance was found by the measurement of a cavity impedance. The cavity impedance compensated coupling loss was redrawn on the Smith Chart. The loaded Q and coupling factor were obtained based on the compensated impedance locus and then the unloaded Q factor was calculated. To verify the proposed procedure, the cavity with lossless coupling was measured. The two measurement results in the lossy and lossless coupling agree well. The results confirm the proposed procedure is valid.

Rotational capacity of shallow footings and its implication on SSI analyses

  • Blandon, Carlos A.;Smith-Pardo, J. Paul;Ortiz, Albert
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.591-617
    • /
    • 2015
  • Standards for seismic assessment and retrofitting of buildings provide deformation limit states for structural members and connections. However, in order to perform fully consistent performance-based seismic analyses of soil-structure systems; deformation limit states must also be available for foundations that are vulnerable to nonlinear actions. Because such limit states have never been established in the past, a laboratory testing program was conducted to study the rotational capacity of small-scale foundation models under combined axial load and moment. Fourteen displacement-controlled monotonic and cyclic tests were performed using a cohesionless soil contained in a $2.0{\times}2.0{\times}1.2m$ container box. It was found that the foundation models exhibited a stable hysteretic behavior for imposed rotations exceeding 0.06 rad and that the measured foundation moment capacity complied well with Meyerhof's equivalent width concept. Simplified code-based soil-structure analyses of an 8-story building under an array of strong ground motions were also conducted to preliminary evaluate the implication of finite rotational capacity of vulnerable foundations. It was found that for the same soil as that of the experimental program foundations would have a deformation capacity that far exceeds the imposed rotational demands under the lateral load resisting members so yielding of the soil may constitute a reliable source of energy dissipation for the system.

A method for predicting the aerodynamic performance of low-speed airfoils (저속익형의 공기역학적 성능예측의 한 방법)

  • Yu, Neung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.240-252
    • /
    • 1998
  • The purpose of this study is to develop a method for predicting the aerodynamic performance of the low speed airfoils in the 2-dimensional, steady and viscous flow. For this study, the airfoil geometry is specified by adopting the longest chord line system and by considering local surface curvature. In case of the inviscid incompressible flow, the analysis is accomplished by the linearly varying strength vortex panel method and the Karman-Tsien correction law is applied for the inviscid compressible flow analysis. The Goradia integral method is adopted for the boundary layer analysis of the laminar and turbulent flows. Viscous and inviscid solutions are converged by the Lockheed iterative calculating method using the equivalent airfoil geometry. The analysis of the separated flow is performed using the Dvorak and Maskew's method as the basic method. The wake effect is also considered by expressing its geometry using the formula of Summey and Smith when no separation occurs. The computational efficiency is verified by comparing the computational results with experimental data and by the shorter execution time.

Development of Comprehensive Nursing Intervention for the Client with Lymphedema (통합적 림프부종 간호중재 개발 연구)

  • Cho, Myoung-Ok;Jung, Hyang-Mi;Jun, Jum-Yee;Sohn, Sue-Kyung;Yoo, Young-Ja;No, Mi-Young;Park, Soon-Ok
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.2
    • /
    • pp.316-326
    • /
    • 2003
  • Purpose: The purpose of this study was the development of a comprehensive nursing intervention program for the client with acute lymph stasis and stage I lymphedema. Method: The Quasi-experimental design using a non-equivalent control group was used. The subjects were 22 stroke patients with lymph stasis in the control group and 23 patients in the experimental group. The complex physical therapy of Casley-Smith was carried out to the control group for 10 hours, and comprehensive nursing intervention for the experimental group was carried out for 60 minutes. The data for this study was gathered from Feb. 2002 until June 2002 and pertains knowledge about lymphedema, self-care for managing lymphedema, and circumferences of affected limbs. Data was analyzed by mean, standard deviation, ${\chi}^2-test$, and t-test. Result: The changes in knowledge about lymphedema, self-care practices, and circumference of affected limbs after nursing intervention did not show significant differences between control group and experiment group. Conclusion: It can be concluded that comprehensive nursing intervention had more efficiency than complex physical therapy in the treatment of edema for stroke patients because of it's simplicity and time saving. Thereby, the comprehensive nursing intervention program developed in this study would be a useful therapy for the clients with lymph stasis and early stage lymphedema.

  • PDF

Purification and Characteristics of New Biopolymer Produced by Alkaline-Tolerant Bacillus sp. (알칼리 내성 Bacillus sp.가 생산하는 생물 고분자의 정제 및 특성)

  • Lee, Shin-Young;Won, Suk;Kang, Tae-Su;Lee, Myong-Yurl;Lew, In-Deok;Kim, Jin-Young
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.554-560
    • /
    • 1998
  • Biopolymer from alkaline-tolerant Bacillus so. was purified, and its physico-chemical and structural properties were investigated. Crude biopolymer, precipitated by acetone from culture broth was fractionated into two fractions by gel chromatography on Sephadex G-200. Among two fractions, one fraction(PS I), which an acidic biopolymer precipitated by the CPC(cetylpyridinium chloride) treatment was studied further. PS I fraction had carboxyl groups and was positive at color reaction of sugar. PS I fraction also showed UV absorbance at 190-225nm. The purified acidic biopolymer was composed of 4% glucose, 8% glucosamine and 88% glutamic acid. Sugar components of the purified acidic biopolymer seemed to be linked to PGA(polyglutamic acid) which existed in the from of ${\gamma}$-peptide bond. By the results of Smith degradation of sugar components, glucose and glucosamine was bound by 1,3 glocosidic linkage. Therefore, this biopolymer was a glycopeptide, oligosaccaride ${\gamma}$-PGA. We concluded that the equivalent weight and the molecular weight of this biopolymer were estimated as about 171 and 5x105 dalton, respectively.

  • PDF

BENZENE AND LEUKEMIA An Epidemiologic Risk Assessment

  • Rinsky Robert A.;Smith Alexander B.;Hornung Richard;Filloon Thomas G.;Young Ronald J.;Okun Andrea H.;Landrigan Philip J.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.651-657
    • /
    • 1994
  • To assess quantitatively the association between benzene exposure and leukemia, we examined the mortality rate of a cohort with occupational exposure to benzene. Cumulative exposure for each cohort member was estimated from historical air-sampling data and, when no sampling data existed, from interpolation on the basis of existing data. The overall standardized mortality ratio (a measure of relative risk multiplied by 100) for leukemia was 337 (95 percent confidence interval, 154 to 641), and that for multiple myeloma was 409 (95 percent confidence interval, 110 to 1047). With stratification according to levels of cumulative exposure, the standardized mortality ratios for leukemia increased from 109 to 322, 1186, and 6637 with increases in cumulative benzene exposure from less than 40 parts per million-years (ppm-years), to 40 to 199, 200 to 399, and 400 or more. respectively. A cumulative benzene exposure of 400 ppm years is equivalent to a mean annual exposure of 10 ppm over a 40-year working lifetime; 10 ppm is the currently enforceable standard in the United States for occupational exposure to benzene. To examine the shape of the exposure-response relation, we performed a conditional logistic-regression analysis, in which 10 controls were matched to each cohort member with leukemia. From this model, it can be calculated that protection from benzene induced leukemia would increase exponentially with any reduction in the permissible exposure limit.

  • PDF