• 제목/요약/키워드: Smart monitoring

검색결과 1,870건 처리시간 0.031초

차세대 USN기반의 스마트 플랜트안전 프레임워크 개발 (SPSF : Smart Plant Safety Framework based on Reliable-Secure USN)

  • 정지은;송병훈;이형수
    • 정보통신설비학회논문지
    • /
    • 제9권3호
    • /
    • pp.102-106
    • /
    • 2010
  • Recently process industries from oil and gas procedures and mining companies to manufactures of chemicals, foods, and beverages has been exploring the USN (Ubiquitous Sensor Networks) technology to improve safety of production processes. However, to apply the USN technology in the large-scale plant industry, reliability and security issues are not fully addressed yet, and the absence of the industrial sensor networking standard causes a compatibility problem with legacy equipment and systems. Although this situation, process industry such as energy plants are looking for the secure wireless plant solution to provide detailed, accurate safety monitoring from previously hard-reach, unaccordable area. In this paper, SPSF (Smart Plant Safety Framework based on Reliable-Secure USN) is suggested to fulfill the requirements of high-risk industrial environments for highly secure, reliable data collection and plant monitoring that is resistant to interference. The SPSF consists of three main layers: 1) Smart Safety Sensing Layer, 2) Smart Safety Network Layers, 3) Plant Network System Layer.

  • PDF

유비쿼터스 투약 감시를 위한 스마트 투약 팩 (A Smart Drug/Medicine Pack for u-Medication Monitoring)

  • 박장환;이태수;김영철
    • 제어로봇시스템학회논문지
    • /
    • 제12궈1호
    • /
    • pp.23-27
    • /
    • 2006
  • As a pervasive healthcare application to help medication of elderly patients, the smart compliance monitors have been recently proposed. In this paper, we present a new smart drug/medicine pack (SDP) for ubiquitous medication monitoring, for which the packaging is either paper packet or blister pack. This ubiquitous compliance monitor is composed of several SDPs and a Bluetooth equipped PDA phone. The SDP is a wireless module that monitors the medication consumption unobtrusively by transmitting the sensed data of 'drug removal' events to the medical center and by reminding patients when they take a dose on their mobile phone. The communication between SDP modules and PDA is realized via Bluetooth. The PDA is basically embedded to indicate the medication record and to alert every prescribed medication time during treatment. Experimental results show that the proposed system works exactly when the SDPs are far within about 2 [m] from PDA.

C 언어로 구현된 스마트 그리드 모니터링 시스템을 위한 LabVIEW와 C 언어의 TCP/IP통신 (TCP/IP communication between LabVIEW and C language for Smart Grid Monitoring System)

  • 김주은;최남섭;양효식;한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.359-360
    • /
    • 2010
  • In smart grid system which uses photovoltaic system, fuel cells and so on, a program implemented with C language is used for control and measurement. When using programs implemented with C language GUI is difficult to watch control and monitor the smart grid system. But LabVIEW is a graphical programming language and it is easy to design GUI screen and to manage many variables such as real-time output of electric power including solar cell, wind power system and fuel cell. This paper suggests LabVIEW and C-language TCP/IP communication for smart grid monitoring system i mplemented with C-language.

  • PDF

전력계통 제어시스템 구조에 따른 사이버 보안대책 수립 (Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems)

  • 우필성;김발호
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

Continuous Human Activity Detection Using Multiple Smart Wearable Devices in IoT Environments

  • Alshamrani, Adel
    • International Journal of Computer Science & Network Security
    • /
    • 제21권2호
    • /
    • pp.221-228
    • /
    • 2021
  • Recent improvements on the quality, fidelity and availability of biometric data have led to effective human physical activity detection (HPAD) in real time which adds significant value to applications such as human behavior identification, healthcare monitoring, and user authentication. Current approaches usually use machine-learning techniques for human physical activity recognition based on the data collected from wearable accelerometer sensor from a single wearable smart device on the user. However, collecting data from a single wearable smart device may not provide the complete user activity data as it is usually attached to only single part of the user's body. In addition, in case of the absence of the single sensor, then no data can be collected. Hence, in this paper, a continuous HPAD will be presented to effectively perform user activity detection with mobile service infrastructure using multiple wearable smart devices, namely smartphone and smartwatch placed in various locations on user's body for more accurate HPAD. A case study on a comprehensive dataset of classified human physical activities with our HAPD approach shows substantial improvement in HPAD accuracy.

Integrated GIS-Based Logistics Process Monitoring Framework with Convenient Work Processing Environment for Smart Logistics

  • Yu, Yeong-Woong;Jung, Hoon;Bae, Hyerim
    • ETRI Journal
    • /
    • 제37권2호
    • /
    • pp.306-316
    • /
    • 2015
  • In today's highly competitive business environment, most companies try to manage their logistics function strategically to satisfy their orders as cost-effectively as possible and maximize their present and future profits. In this environment, logistics process visibility is essential to companies wishing to competently track components, parts, or products in transit from the original suppliers to the final destinations. Thus, it is important to provide instantly and easily recognizable information about such visibility to all stakeholders, especially customers. To ensure a high-level geographical visibility of the logistics processes, in this paper, we propose a way of implementing a GIS-based logistics process monitoring environment and of integrating a performer's work processing environment on the monitoring system. Additionally, to provide more abundant monitoring information, we describe a procedure for creating and processing various monitoring information, which are represented as ECA rules in this work processing environment. Therefore, it is possible to provide intuitive and visible monitoring information regarding the logistics process and resource elements.

네트워크 보안 관제를 위한 로그 시각화 방법 (A log visualization method for network security monitoring)

  • 조우진;신효정;김형식
    • 스마트미디어저널
    • /
    • 제7권4호
    • /
    • pp.70-78
    • /
    • 2018
  • 정보시스템에서 정보 보안의 중요성이 강조됨에 따라 이에 대응하기 위해 많은 기업이 보안 솔루션을 도입하고 있다. 하지만 많은 예산을 들여도 이를 관리하는 보안 관제가 없으면 제대로 기능하지 못하게 된다. 보안 관제는 문제 발생 시 빠른 대처가 필수적이며, 관제 목적에 맞는 적절한 시각화 대시보드를 설계하여 필요한 정보를 빠르게 전달할 수 있도록 할 필요가 있다. 본 논문에서는 오픈소스 Elastic Stack을 이용하여 보안 로그를 시각화 하는 방법을 제시하고, 관제 목적에 적합한 대시보드로 구현함으로써 제시된 방법이 네트워크 보안 관제에 적합함을 보인다. 대시보드는 비정상적인 트래픽 증가와 공격 경로 분석 등의 목적으로 효과적으로 활용될 수 있음을 확인하였다.

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구 (A Study on the Power Loss Monitoring Methods with AMI systems)

  • 명노길
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

Innovative cable force monitoring of stay cables using piezoelectric dynamic strain responses

  • ;;이지용;신성우;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.830-834
    • /
    • 2013
  • This study presents a method to monitor cable force of a long-span cable-stayed bridge using a smart piezoelectric sensor system. The following approaches are implemented in order to achieve the objective. Firstly, the method to utilize piezoelectric materials for the health monitoring of stay cables is presented. For strain measurement of a stay cable, a PZT-embedded smart skin is designed to overcome the difficulties of bonding PZT sensors directly on stay cables. Secondly, a piezoelectric strain monitoring system for stay cables is designed. For the operation of the sensor board, the Imote2 sensor platform is used to provide the computation, wireless communication and power supply units. The feasibility of the proposed monitoring system is then evaluated on a full-scale cable of a cable-stayed bridge.

  • PDF