• Title/Summary/Keyword: Small-signal

Search Result 2,295, Processing Time 0.027 seconds

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

A Study on Analysis of Frequency Response with Hydraulic Circuit Analysis Module (유압 회로 해석 모듈을 이용한 주파수 응답 해석에 관한 연구)

  • 전봉근;송창섭;이용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.581-584
    • /
    • 1995
  • The frequency response of a electro-hydraulic servo(EHS) system is studied. The frequensy response characteristics of the EHS system obtained by linerization method, nonlinerar simulation method, and experimentation are compared ane another. It is found that the frequency response of the EHS is consistent when input signal applied is very small, but that is deviated as input signal becomes large.

  • PDF

A Study on Small-signal and Large-signal Equivalent Model for Diodes (다이오드의 소신호 및 대신호 등가모델에 관한 연구)

  • 최민수;양승인;전용구
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.267-271
    • /
    • 2001
  • 다이오드의 소신호 및 대신호 파라미터 추출은 DC 해석, 외부 기생 소자 추출, 마지막으로 5-파라미터에 의한 내부소자 추출로 이루어진다. DC IV-곡선과 S-파라미터의 curve-fitting으로 내부 파라미터를 구하였고 외부 기생소자는 바이어스에 따라 변하지 성질을 이용하였다. 사용된 소자는 Schottky diode는 SIEMENS사의 BAS125를, Varactor diode는 SONY사의 1t362를, PIN diode는 Hitachi사의 HVM14S를 모델로 사용하였다. 실측을 위해 사용된 소자는 각각 HP사의 HSMS-2822, SONY사의 1t362, HP사의 HSMP-3834을 이용하여 측정하였다.

  • PDF

Analysis of the error signals for infrared reticle seekers in multiple targets (다중 표적에 대한 적외선 레티클 탐색기의 오차 신호 분석)

  • 한성현;홍현기;최종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1438-1446
    • /
    • 1996
  • Infrared seekers using reticles with a single detector have been widely used due to small size and low cost. However, the analysis of the error signals and the performance in multiple targets are performed either simplistically or not at all. In this paper, we present detector signals and processing results using image and signal processing techniques, especially performance analysis in multiple targets. The simulation results are essential to make the advanced signal processing part of retical seekers which can deal with various engagement scenarios.

  • PDF

Improvement of acoustic feedback stability by bandwidth compression and expansion

  • 염동홍;안수길
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.16-21
    • /
    • 1985
  • Both shifiting the input signal's frequencies by a fixed frequency and compressing the input signal's bandwidth have been known to be effective in improving the stability margin of public adress systems operating in reverberant spaces. This paper describes the effect of an alternative approach of improving the acoustic-feedback stability and yet maintaining speech inteligibility by bandwidth compression and expansion. Conditions are derived for this technizue to be realized and an experimental system has been made - up. A series of experiments has been performed in small spaces and the results have shown that more than 5dB improvement can be obtained in the stability margin.

  • PDF

Investigation of Open-Loop Transmit Power Control Parameters for Homogeneous and Heterogeneous Small-Cell Uplinks

  • Haider, Amir;Sinha, Rashmi Sharan;Hwang, Seung-Hoon
    • ETRI Journal
    • /
    • v.40 no.1
    • /
    • pp.51-60
    • /
    • 2018
  • In Long Term Evolution (LTE) cellular networks, the transmit power control (TPC) mechanism consists of two parts: the open loop (OL) and closed loop. Most cellular networks consider OL/TPC because of its simple implementation and low operation cost. The analysis of OL/TPC parameters is essential for efficient resource management from the cellular operator's viewpoint. In this work, the impact of the OL/TPC parameters is investigated for homogeneous small cells and heterogeneous small-cell/macrocell network environments. A mathematical model is derived to compute the transmit power at the user equipment, the received power at the eNodeB, the interference in the network, and the received signal-to-interference ratio. Using the analytical platform, the effects of the OL/TPC parameters on the system performance in LTE networks are investigated. Numerical results show that, in order to achieve the best performance, it is appropriate to choose ${\alpha}_{small}=1$ and $P_{o-small}=-100dBm$ in a homogenous small-cell network. Further, the selections of ${\alpha}_{small}=1$ and $P_{o-small}=-100dBm$ in the small cells and ${\alpha}_{macro}=0.8$ and $P_{o-macro}=-100dBm$ in the macrocells seem to be suitable for heterogeneous network deployment.

A New Adaptive Echo Canceller with an Improved Convergence Speed and NET Detection Performance (향상된 수렴속도와 근달화자신호 검출능력을 갖는 적응반향제기기)

  • 김남선;박상택;차용훈;윤일화;윤대희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.12
    • /
    • pp.12-20
    • /
    • 1993
  • In a conventional adaptive echo canceller, an ADF(Adaptive Digital Filter) with TDL(Tapped-Delay Line) structure modelling the echo path uses the LMS(Least Mean Square) algorithm to compute the coefficients, and NET detector using energy comparison method prevents the ADF to update the coefficients during the periods of the NET signal presence. The convergence speed of the LMS algorithm depends on the eigenvalue spread ratio of the reference signal and NET detector using the energy comparison method yields poor detection performance if the magnitude of the NET signal is small. This paper presents a new adaptive echo canceller which uses the pre-whitening filter to improve the convergence speed of the LMS algorithm. The pre-whitening filter is realized by using a low-order lattice predictor. Also, a new NET signal detection algorithm is presented, where the start point of the NET signal is detected by computing the cross-correlation coefficient between the primary input and the ADF output while the end point is detected by using the energy comparison method. The simulation results show that the convergence speed of the proposed adaptive echo canceller is faster than that of the conventional echo canceller and the cross-correlation coefficient yields more accurate detection of the start point of the NET signal.

  • PDF

On Improving Convergence Speed and NET Detection Performance for Adaptive Echo Canceller (향상된 수렴 속도와 근단 화자 신호 검출능력을 갖는 적응 반향 제거기)

  • 김남선
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.23-28
    • /
    • 1992
  • The purpose of this paper is to develop a new adaptive echo canceller improving convergence speed and near-end-talker detection performance of the conventional echo canceller. In a conventional adaptive echo canceller, an adaptive digital filter with TDL(Tapped-Delay Line) structure modelling the echo path uses the LMS(Least Mean Square) algorithm to cote the coefficients, and NET detector using energy comparison method prevents the adaptive digital filter to update the coefficients during the periods of the NET signal presence. The convergence speed of the LMS algorithm depends on the eigenvalue spread ratio of the reference signal and NET detector using the energy comparison method yields poor detection performance if the magnitude of the NET signal is small. This paper presents a new adaptive echo canceller which uses the pre-whitening filter to improve the convergence speed of the LMS algorithm. The pre-whitening filter is realized by using a low-order lattice predictor. Also, a new NET signal detection algorithm is presented, where the start point of the NET signal is detected by computing the cross-correlation coefficient between the primary input and the ADF(Adaptive Digital Filter) output while the end point is detected by using the energy comparison method. The simulation results show that the convergence speed of the proposed adaptive echo canceller is faster than that of the conventional echo canceller and the cross-correlation coefficient yield more accurate detection of the start point of the NET signal.

  • PDF

Ultrasonic Inspection of Cracks in Stud Bolts of Reactor Vessels in Nuclear Power Plants by Signal Processing of Differential Operation

  • Choi, Sang-Woo;Lee, Joon-Hyun;Oh, Won-Deok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.439-445
    • /
    • 2005
  • The stud bolt is one of crucial parts for safe operation of reactor vessels in nuclear power plants, Crack initiation and propagation were reported in stud bolts that arc used for closure of reactor vessel and head, Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure which could induce radioactive leakage from nuclear reactor, In conventional ultrasonic testing for inspection of stud bolts, cracks are detected by using shadow effect It takes too much time to inspect stud bolts by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread, In this study, the signal processing technique for enhancing conventional ultrasonic technique was introduced for inspecting stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. Detectability for small crack was enhanced by using this signal processing in ultrasonic inspection of stud bolts in Nuclear Power Plants.

Heartbeat Detection based on Signal Reflected from Antenna in Mobile Device (휴대기기에서의 안테나 반사 신호를 이용한 심박 신호 검출)

  • An, Yong-Jun;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.643-649
    • /
    • 2013
  • In this paper, human heartbeat detection using signal reflected from the antenna which is varied reflection coefficient by near field variation of the antenna. For detection reflected signal from antenna, 20 dB directional coupler is used because of not affecting transmitting signal. Variance of reflection coefficient of dipole antenna is about 0.07 dB which is too small the distinction between heartbeat and noise. Sensitivity increasing method is applied and heartbeat is clearly detected. Due to phase and magnitude errors come from discrete value components, antenna is located some points in experiments ro find optimum sensitivity position. And providing verification of using communication signal, heartbeat detection when frequency modulated signal which have 4 MHz bandwidth is applied.