• Title/Summary/Keyword: Small-signal

Search Result 2,289, Processing Time 0.03 seconds

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

A Study on Design and Manufacturing Methods of Dual-Polarization Monopulse Feed Structure in Millimeter-wave(W band) (밀리미터파(W대역) 이중편파 모노펄스 급전 구조 설계 및 제작 방안 연구)

  • Jong-Gyun Baek;Hyeong-Ki Lee;Young-Wan Kim;Hee-Duck Chae;Ji-Han Joo;Jaesik Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.47-53
    • /
    • 2023
  • In this paper, We designed a waveguide-type feed structure that converts millimeter wave dual-polarized signals into monopulse signals and presented a manufacturing method. At millimeter-wave such as the W band, the size of the waveguide is very small, making it very difficult to manufacture complex structures. Therefore, because manufacturability is important for the waveguide-type feed structure in the millimeter-wave, electro forming and diffusion bonding were proposed and verified in this study. The designed monopulse feed structure consists of eight 180° hybrids that combine 90° hybrids and self-compensating phase shifters, and four OMTs to separate dual polarization. The designed feed structure was designed to facilitate electro forming and diffusion bonding, and the manufactured feed structure was verified through a network analyzer. It was confirmed that the two proposed production methods produce a monopulse signal well through the measured magnitude and phase of the port.

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

GaN-based Low Noise Amplifier MMIC for X-band Applications (X-대역 응용을 위한 GaN 기반 저잡음 증폭기 MMIC)

  • Byeong-Ok Lim;Joo-Seoc Go;Sung-Chan Kim
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.33-37
    • /
    • 2024
  • In this paper, we report the design and the measurement of a X-band low noise amplifier (LNA) monolithic microwave integrated circuit (MMIC) using a 0.25 ㎛ gate length microstrip GaN-on-SiC high electron mobility transistor (HEMT) technology. The developed X-band GaN-based LNA MMIC achieves small signal gain of 22.75 dB ~ 25.14 dB and noise figure of 1.84 dB ~ 1.94 dB in the desired band of 9 GHz to 10 GHz. Input and output return loss values are -11.36 dB ~ -24.49 dB and -11.11 dB ~ -17.68 dB, respectively. The LNA MMIC can withstand 40 dBm (10 W) input power without performance degradation. The chip dimensions are 3.67 mm × 1.15 mm. The developed GaN-based LNA MMIC is applicable to various X-band applications.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam (6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구)

  • Choi, Sang-Hyoun;Huh, Hyun-Do;Kim, Seong-Hoon;Ji, Young-Hoon;Kim, Kum-Bae;Kim, Woo-Chul;Kim, Hun-Jeong;Shin, Dong-Oh;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.216-223
    • /
    • 2011
  • Recently PTW developed a MicroLion liquid ionization chamber which is water_equivalent and has a small sensitive volume of $0.002cm^3$. The aim of this work is to investigate such dosimetric characteristics as dose linearity, dose rate dependency, spatial resolution, and output factors of the chamber for the external radiotherapy photon beam. The results were compared to those of Semiflex chamber, Pinpoint chamber and Diode chamber with the sensitive volumes of $0.125cm^3$, $0.03cm^3$ and $0.0025cm^3$, respectively and evaluated to be suitable for small fields. This study was performed in the 6MV photon energy from a Varian 2300 C/D linac accelerator and the MP3 water phantom (PTW, Freiburg) was used. Penumbras in the varios field sizes ranged from $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ were used to evaluate the spatial resolution. Output factors were measured in the field sizes of $0.5{\times}0.5$ to $40{\times}40cm^2$. Readings of the chamber was linearly proportional to dose. Dose rate dependency was measured from 100 MU/min to 600 MU/min, showed a maximum difference of 5.0%, and outputs decreased with dose rates. The spatial resolutions determined with comparing profiles for the field sizes of $0.5{\times}0.5cm^2$ to $10{\times}10cm^2$ agreed between every detector except the Semiflex chamber to within 2%. Outputs of detectors were compared to that of Semiflex chamber and showed good agreements within 2% for every chamber. This study shows that MicroLion chamber characterized by a high signal-to-noise ratio and water equivalence could be suitable for the small field dosimetry.

Analysis of Bone Marrow Micrometastasis Using RT-PCR in Patients with Small Cell Lung Carcinoma (소세포 폐암에서 역전사 중합효소 연쇄반응(RT-PCR)을 이용한 골수 미세전이(naicronaetastasis)의 분석)

  • Kim, Tae-You;Park, Jong-Kook;Ryoo, Baek-Ryeol;Im, Yung-Hyuck;Kang, Yoon-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.797-806
    • /
    • 1999
  • Background: About 20% of small cell lung cancer(SCLC) patients have bone marrow(EM) metastasis at the time of diagnosis and the remaining patients are also considered with micrometastasis. In an attempt to detect EM micrometastasis, we used cytokeratin(CK)-20 as a molecular marker, which is specific for epithelial cells. Method: A sensitive RT-PCR assay was used to compare CK-20 expression both in SCLC cell line H209 and normal leukocyte and to evaluate EM aspirates of 28 SCLC patients. Result: H209 cell line showed CK-20 expression but normal leukocyte did not, suggesting CK-20 expression is lung tissue-specific. Of 28 patients(11 limited disease, 17 extensive disease), only 2(1/11, 1/17) samples tested revealed positive signal for CK-20. Two patients with CK-20 expression had EM metastasis or multiple bone involvement during follow-up. Conclusion: Although circulating tumor cells were detected in EM of small portion of patients with bone metastasis, CK-20 doesn't seem to be a reliable marker for the detection of micrometastasis in SCLC. This study emphasizes that identification of more specific marker for micrometastsis is mandatory prior to clinical application.

  • PDF

Expression of EGFR in Non-small Cell Lung Cancer and its Effects on Survival (비소세포 폐암에서 EGFR의 발현률과 생존률에 미치는 영향)

  • Kim, Hak-Ryul;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1285-1295
    • /
    • 1997
  • Background : EGFR is one of the initial step in signal transduction pathway about multistep carcinogenesis. It is homologous to oncogene erbB-2 and is the receptor for EGF and TGF alpha. EGFR has important role in the growth and differentiation of tumor cells. So, EGFR in non-small cell lung cancer was examined to search for possible evidence as clinical prognostic factor. Methods : To investigate the role of EGFR in lung cancer, the author performed immunohistochemical stain of EGFR on 57 resected primary non-small cell lung cancer specimens. And the author analyzed the correlation between EGFR expression, clinical parameters, Sand $G_1$ phase fraction and survival. Results : 1) EGFR were detected in 56% of total 57 patients (according to histologic type, squamous cancer 50%, adenocarcinoma 63%, large cell cancer 75%) (according to TNM stage, stage I 64%, stage II 38%, stage III 55%) (according to cellular differentiation, well 50%, moderately 52%, poorly 65%). All differences were insignificant 2) Using the flow cytometric analysis, mean S-phase fraction of EGFR (+) and (-) group were 22.3(${\pm}10.5$)%. 18.0(${\pm}10.9$)% (p>0.05), mean $G_1$-phase fraction of EGFR (+) and (-) group were 68.4(${\pm}11.6$)%, 71.1(${\pm}12.8$)%, (p>0.05) 3) Two-year survival rate of EGFR (+) and (-) group were 53%, 84%, median survival time of EGFR (+) and (-) group were 26, 53 months. (p<0.05, Kaplan-Meier, generalized Wilcox) Conclusion : EGFR immunostaining may be a simple and useful method for survival prediction in non-small cell lung cancer.

  • PDF

The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition (PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화)

  • Hong, Gun-Chul;Park, Sun-Myung;Kwak, In-Suk;Lee, Hyuk;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Purpose: Partial volume effect (PVE) is the phenomenon to lower the accuracy of image due to low estimate, which is to occur from PET/CT 3D image acquisition. The more resolution is declined and the lesion is small, the more it causes a big error. So that it can influence the test result. Studied the optimum image reconstruction method by using variation of parameter, which can influence the PVE. Materials and Methods: It acquires the image in each size spheres which is injected $^{18}F$-FDG to hot site and background in the ratio 4:1 for 10 minutes by using NEMA 2001 IEC phantom in GE Discovey STE 16. The iterative reconstruction is used and gives variety to iteration 2-50 times, subset number 1-56. The analysis's fixed region of interest in detail part of image and compute % difference and signal to noise ratio (SNR) using $SUV_{max}$. Results: It's measured that $SUV_{max}$ of 10 mm spheres, which is changed subset number to 2, 5, 8, 20, 56 in fixed iteration to times, SNR is indicated 0.19, 0.30, 0.40, 0.48, 0.45. As well as each sphere's of total SNR is measured 2.73, 3.38, 3.64, 3.63, 3.38. Conclusion: In iteration 6th to 20th, it indicates similar value in % difference and SNR ($3.47{\pm}0.09$). Over 20th, it increases the phenomenon, which is placed low value on $SUV_{max}$ through the influence of noise. In addition, the identical iteration, it indicates that SNR is high value in 8th to 20th in variation of subset number. Therefore, to reduce partial volume effect of small lesion, it can be declined the partial volume effect in iteration 6 times, subset number 8~20 times, considering reconstruction time.

  • PDF

Association Analysis between Chromogranin B Genetic Variations and Smooth Pursuit Eye Movement Abnormality in Korean Patients with Schizophrenia (한국인 조현병 환자에서 Chromogranin B 유전자와 안구운동 이상의 연합에 대한 연구)

  • Park, Jin Wan;Pak, Doo Hyun;Hwang, Min Gyu;Lee, Min Ji;Shin, Hyoung Doo;Shin, Tae-Min;Hahn, Sang Woo;Hwang, Jaeuk;Lee, Yeon Jung;Woo, Sung-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.4
    • /
    • pp.101-109
    • /
    • 2018
  • Objectives According to previous studies, the Chromogranin B (CHGB) gene could be an important candidate gene for schizophrenia which is located on chromosome 20p12.3. Some studies have linked the polymorphism in CHGB gene with the risk of schizophrenia. Meanwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. Methods We measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. Results The natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). Conclusions Despite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.nwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. MethodsZZWe measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. ResultsZZThe natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). ConclusionsZZDespite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.

  • PDF