• Title/Summary/Keyword: Small diameter tube

Search Result 188, Processing Time 0.025 seconds

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

Effect of the catalyst deposition rates on the growth of carbon nanotubes

  • Ko, Jae-Sung;Choi, In-Sung;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.264-264
    • /
    • 2010
  • Single-walled carbon nanotubes (SWCNTs) were grown on a Si wafer by using thermal chemical vapor deposition (t-CVD). We investigated the effect of the catalyst deposition rate on the types of CNTs grown on the substrate. In general, smaller islands of catalyst occur by agglomeration of a catalyst layer upon annealing as the catalyst layer becomes thinner, which results in the growth of CNTs with smaller diameters. For the same thickness of catalyst, a slower deposition rate will cause a more uniformly thin catalyst layer, which will be agglomerated during annealing, producing smaller catalyst islands. Thus, we can expect that the smaller-diameter CNTs will grow on the catalyst deposited with a lower rate even for the same thickness of catalyst. The 0.5-nm-thick Fe served as a catalyst, underneath which Al was coated as a catalyst support as well as a diffusion barrier on the Si substrate. The catalyst layers were. coated by using thermal evaporation. The deposition rates of the Al and Fe layers varied to be 90, 180 sec/nm and 70, 140 sec/nm, respectively. We prepared the four different combinations of the deposition rates of the AI and Fe layers. CNTs were synthesized for 10 min by flowing 60 sccm of Ar and 60 sccm of $H_2$ as a carrier gas and 20 sccm of $C_2H_2$ as a feedstock at 95 torr and $810^{\circ}C$. The substrates were subject to annealing for 20 sec for every case to form small catalyst islands prior to CNT growth. As-grown CNTs were characterized by using field emission scanning electron microscopy, high resolution transmission electron microscopy, Raman spectroscopy, UV-Vis NIR spectroscopy, and atomic force microscopy. The fast deposition of both the Al and Fe layers gave rise to the growth of thin multiwalled CNTs with the height of ${\sim}680\;{\mu}m$ for 10 min while the slow deposition caused the growth of ${\sim}800\;{\mu}m$ high SWCNTs. Several radial breathing mode (RBM) peaks in the Raman spectra were observed at the Raman shifts of $113.3{\sim}281.3\;cm^{-1}$, implying the presence of SWCNTs (or double-walled CNTs) with the tube diameters 2.07~0.83 nm. The Raman spectra of the as-grown SWCNTs showed very low G/D peak intensity ratios, indicating their low defect concentrations.

  • PDF

Detection of Irradiated Chicken, Pork and Beef by ESR Spectroscopy (닭고기, 돼지고기 및 쇠고기의 방사선 조사 유무 판별을 위한 ESR Spectroscopy의 활용)

  • Yang, Jae-Seung;Kim, Choong-Ki;Lee, Hae-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.606-611
    • /
    • 1999
  • To identify irradiated foods, studies have been carried out with electron spin resonance (ESR) spectroscopy on bone containing foods, such as chicken, pork, and beef. Bones cleaned, pieced and dried were irradiated with doses of 0, 1, 3, 5 kGys using a $Co^{60}$ irradiator. The bones were placed in a resonant quartz tube with an internal diameter of about 4.0 mm within the Bruker Win-ESR spectrometer, and the intensity of the ESR signal could be quantified by double integration of the first derivative spectrum. The irradiated bone presented an asymmetric absorption in shape, different from that of an unirradiated one. It could be possible to detect at doses lower than 1 kGy below the dose employed commercially (3 kGy) in the case of irradiated chicken bone. The signal intensity was greatest in the beef bone, intermediate in the pork bone and lowest in the chicken bone; it was normally lower for smaller animals than for larger species, and small variations were observed between samples of the same species. The intensity of the signal induced in bones increased linearly with irradiation doses in the range of 1.0 kGy to 5.0 kGy, and it was possible to distinguish between samples given low and high doses of irradiation. The signal stability for 6 weeks made them ideal for the quick and easy identification of irradiated meats.

  • PDF

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

External Morphology of the American Leafminer, Liriomyza trifolii (Diptera: Agromyzidae), on Tomato with Scanning Electron Microscope (주사전자현미경을 이용한 토마토에 발생하는 아메리카잎굴파리(Liriomyza trifolii)의 외부형태적 특징)

  • Youn, Young-Nam;Kim, Ki-Duck;Park, Su-Jin;Kim, Nam-Sung;Seo, Mi-Ja;Chae, Soon-Yong
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • The external morphology of male and female of Liriomyza trifolii (Burgess) was studied using the scanning electron microscopy (SEM). Three types of sensilla were identified on the funicle of antennae. The trichoid sensilla were most conspicious and distributed with a characteristic sharp structure at the apical end. Basiconic sensilla were showed distal curvature about $13{\mu}m$ long and $1.2{\mu}m$ to $1.4{\mu}m$ in diameter. Grooved sensilla were showed a finger-like projections at the peg apex. The function of these sensilla likely to be olfactory. The mouthparts were adapted for sucking food, and formed a elongate rostrum which was incorporated with labrum. The labrum was a small and flap-like shape. The slender and paired maxillary palp seemed to combine with each other lengthwise to long tube. The tarsus typically consisted of 5 segments, which might be variously modified, principally by thickening or flattening. The segment beared a pair of claws. Beneath the claws, there was a pair of pad-like pulvillia and a bristle-like median empodium. L. trifolii might secreted on the pulvillus and empodium an adhesive substance that enable them to cling to smooth surfaces. Male terminalia was complicated. The name 'aedeagus' seemed the best available general term for the copulatory organ, otherwise, female terminalia was usually relatively simple. This structure was reduced and formed a telescopic, eversible, and tubular ovipositor.

  • PDF

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

A Study on Labor Saving in Paddy Rice Cultivation (논벼재배에 있어서의 노동력 절감에 관한 연구)

  • Young-Chul Chang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.11
    • /
    • pp.81-97
    • /
    • 1972
  • Experiments and investigations were done basically and practically for the purpose of labor saving in paddy rice cultivation especially on Homizil i.e. hoeing and herbicide, 1969. 8 concrete tanks were established on the open base of Keon Kuk University for comparison of percolation, dissolved oxygen and yield test of rice in the paddy plot of tank. The dimension of the bottom of each tank is square meter. Each of the 4 of the 8 tanks is 21cm in height and each of the remaining 4 tanks is 36cm. Each tank has a system that comprises 2 sets of tubes, each of which has 20 holes of 5mm in diameter scattered every side and is covered with nylon cloth taking water in the tank. One set consists of 4 P.V.C tubes. The first set is situated 8cm below the top of the tank and the second set is located at bottom layer inside the tank. The 4 tubes of each set are combined together and led to the glass tube which protects from inside to outside. And this inside-outside glass tube is connected to the small rubber tube. Also a glass tube is set 4cm below the top of the tank. Paddy loam was filled on sand in each of the tanks in the soil depth of either 15cm or 30cm. The depth of sand was 5cm in the soil depth of 15cm and 10cm in the soil depth of 30cm. (Fig. 1, 2 and 3). The paddy rice was grown in the tank. The percolation of water, the dissolved oxygen and the yield of rice were observed in the tank. And the dissolved oxygen was detected by Winkler method. A sandy paddy field of heavy percolation was selected at the field of the National Agricultural Material Inspection Center in Seoul. It was divided into 9 plots. These plots were given 3 treatments: (A) not hoeing, (B) hoeing one time and (C) hoeing two times. These treatments were replicated 3 times along the latin square design. The paddy rice was grown and sprayed with Stam F-34 in the all plots for the purpose of killing weeds before hoeing. The two types of paddy of field i.e. one for normal percolation and the other for ill drainage were selected at Iri Crop Experiment Station, Jeonla-Bukdo. Each field was divided into 24 plots for 8 treatments. They are: (A) not hoeing; (B) hoeing one time; (C) hoeing two times; (D) not hoeing but treating with herbicide, Pamcon; (E) hoeing one time and weeding two times also treating with herbicide, Pamcon; (F) hoeing two times and weeding one time a], o treating with herbicide, Pamcon; (G) hoeing two times and weeding two times also treating with herbicide, Pamcon, ; (H) usual manner. The labor hours and expenses needed for weeding in the paddy by hoeing were investigated in a farmer at Suwon and the price of herbicide and the yield of rice were taken out at Iri, Jeonla-Bukdo. The results obtained from the above experiments and investigations are as follows: 1. The relationship between percolation and dissolved oxygen shows that a very small amount of oxygen is detected in the soil water under 2cm below surface of earth in the paddy even when percolation is over 4.0cm per 24 hours (Tab. 1). 2. The relationship between percolation and yield of rice shows that the yield of rice increases in the percolation of 0cm and 1.5cm per 24 hours and decreases in the percolation of 2.5cm and 3.4cm in the plot of the 15cm ploughing depth and increases in the percolation of 1.4cm and 3.0cm and decreases in the percolation of 0cm and 4.0cm in the plot of 30cm ploughing depth (Tab. 1 and Fig. 5). 3. The yield of paddy weeded with Stam F-34 in the sandy field of heavy percolation in Seoul was 3.02 tons in the plot of not hoeing, 2.99 tons in hoeing one time and 3.05 tons in hoeing two times per hectare (Tab. 5). 4.1). 4. 1) The yield of rice per 10 ares in the field of normal percolation at Iri was 338kg in not hoeing, 379kg in hoeing one time, 383kg in hoeing two times, 413kg in spraying herbicide, Pamcon, and not hoeing, 433kg in spraying herbicide, Pamcon, and hoeing one time and weeding two times, 399kg in spraying herbicide, Pamcon, and hoeing two times and weeding one time, 420kg in spraying herbicide, Pamcon, and hoeing two times and weeding two times and 418kg in usual manner (Tab. 6-1). 2) The yield of rice per 10 ares in the field of ill drainage at Iri was 323kg in not hoeing, 363kg in hoeing one time, 342kg in hoeing two times, 388kg in spraying herbicide, Pamcon, and not hoeing, 425kg in spraying herbicide, Pamcon, and hoeing one time and weeding two times, 427kg in spraying herbicide, Pamcon, and hoeing two times and weeding one time, 449kg in spraying herbicide, Pamcon, and hoeing two times and weeding two times and 412kg in usual manner (Tab. 6-2). 5. 1) The labor hours for weeding by hoeing was 37.1 hours but 53.5 hours if hours for meal, smoking and so on are included, and the expenses including labor cost needed for weeding by hoeing in the paddy rice was 2, 346 Won per 10 ares at Suwon (Tab. 7). 2) The labor hours for weeding by spraying herbicide with hand sprayer in the paddy rice was about 5 hours per 10 ares at Suwon and the expenses for weeding by spraying herbicide in the paddy rice was 750 Won but 1130 Won if the loss by decrement of rice in the paddy field of ill drainage per 10 ares is calculated in estimation at Iri (Tab. 8). From these observations and investigations it is known that using of some kinds of herbicides Saves labor and expenses of weeding, almost without giving damages to the rice itself, in the field of normal or heavy percolation comparing usual manner of hoeing.

  • PDF