• Title/Summary/Keyword: Small cone

Search Result 225, Processing Time 0.027 seconds

Numerical Investigation of a Steady Non-Evaporating Hollow-Cone Spray Interacting with an Annular Air Jet (정상 할로우 콘 분무와 환형 공기 제트의 상호작용에 관한 수치적 연구)

  • Kim, Woo-Tae;Huh, Kang-Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.2
    • /
    • pp.43-52
    • /
    • 2000
  • Numerical simulation of steady, non-evaporating hollow-cone sprays interacting with concentric annular air jets is performed using the discrete stochastic particle method in KIVA. The spray characteristics such as SMD, mean droplet velocity, liquid volume flux, air/liquid mass ratio, and droplet number density arc obtained and compared with the measurements involving different air flow rates in large and small annuli. Overall satisfactory agreement is achieved between calculation and experiment except for the deviation in the downstream SMD arising from uncertainty in the size distribution function at injection, and inaccuracy in the averaged spray parameters due to the small volumes of axisymmetric 2-D sector meshes close to the axis.

  • PDF

The Ultrastructure of Photoreceptor Cells in Frog Retina (개구리 망막에 있는 광수용세포의 미세구조)

  • Kim, Jin-Suk;Jeon, Jin-Seok
    • Applied Microscopy
    • /
    • v.25 no.4
    • /
    • pp.115-123
    • /
    • 1995
  • This study was carried out to observe the functional ultrastructures of photoreceptor cells in frog(Rana catesbeiana) retina using transmission electron microscope. The photoreceptor cells are divided into two types-rod and cone cells-consist of outer and inner segment. The long outer segment of rod cell contains dense stacks of membrane and formed vertical and horizontal folds. The outer segment of cone cell is small, and vertical and horizontal folds are not exist. The electron dense cytoplasm of rod cell contains compact mitochondria, Golgi complexes, and endoplasmic reticula. The inner segment of cone cell shows low electron density and contains a large lipid droplet in the upper part of inner segment. In addition, cone cell contains many mitochondria, Golgi complexes. rough endoplasmic reticula, ribosomes and numerous glycogen particles. It is believed that these ultrastructural characteristics are closely associated with photoreceptive function of photoreceptor cells in frog retina.

  • PDF

Development and Application of Ultra Small Micro-Cone Penetrometer (초소형 마이크로콘 관입시험기의 개발 및 적용)

  • Lee, Jong-Sub;Shin, Dong-Hyun;Yoon, Hyung-Koo;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • The disturbance zone and measured values are affected by the size of the penetrometer. The local value may be measured by the smaller penetrometer. An ultra small Micro-Cone penetrometer (5mm in outer diameter) is designed and manufactured to characterize soil properties with minimum disturbance during penetration tests. The tip resistance is measured by using stain gauges attached near the Micro-Cone. In addition, the friction sleeve is adopted to effectively remove the skin friction from the tip resistance. Design concern includes the installation of stain gauges, circuits, penetration systems, penetration rate, sampling rate, operating temperature, and calibration. Application tests show that the clay interface, and the soil layers consisting of clay and sand are clearly detected by the Micro-Cone. Furthermore, the cone tip resistances measured by the Micro-Cone and the miniature cone (16mm in outer diameter) are similar. Note the resolution is much higher in the Micro-Cone. This study shows that the Micro-Cone may effectively detect the soil interface with high resolution, and with minimum disturbance.

Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator (ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰)

  • Moon, Un-Chull;Kim, Hyun-Jin;Kim, Young-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Development of Rotating Cone Type Garlic Clove Separator (II) - Effect by Clearance between Inner and Outer Frustum - (회전 원추형 마늘 쪽분리기 개발에 관한 연구 (II) - 원추 간극의 영향 -)

  • Lee, J.S.;Kim, K.B.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.77-83
    • /
    • 2007
  • The purpose of this study is to find optimal conditions for various outlet clearances of prototype garlic clove separator with a rotating cone in the constant inlet clearance and cone height. Optimal outlet clearance from medium to small size garlics was 25 mm at the $200{\sim}400rpm$. For large garlic, optimal outlet clearances of Namdo and Uiseong garlic were 34 mm and 37 mm, respectively, in the range of $300{\sim}400rpm$. The proportion of garlic separation was over 95% for all quality of garlics. The proportions of damaged garlics at 25 mm and 28 mm outlet clearances were below 5% and below 10%, respectively. Therefore, in order to maintain high performance of garlic separation for the various varieties and qualities, the rotating cone type separator should be designed with cone speed ranges of $200{\sim}400rpm$ and the outlet clearance ranges of $25{\sim}37 mm$. The outlet clearance of the separator should be easily controlled within those ranges.

Cone resistance and electrical resistivity with Depth at Dredged Sea Sand Region (준설해사로 다짐된 방조제 제체 성토부의 콘저항치와 전기비저항 관계)

  • Song, Sung-Ho;Kang, Mi-Kyung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.37-40
    • /
    • 2008
  • We have measured resistivities for undisturbed soil samples collected from dredged bank with sea sand, and analyzed with one-dimensional inversion results from small-loop electromagnetic survey data. From the relationship between the two resistivities, it appeared that calculated resistivities were remarkably consistent with measured resistivities. Correlation relationships between resistivity values and cone resistance were analyzed after comparing inversion results with cone resistance. It turns out that the region with below 1 ohm-m is correspondent to that of with less than $50\;kgf/cm^2$ in dredged bank with sea sand. From the study result, resistivity monitoring of small-loop EM periodically is proved to be more effective to maintain the stability of embankment dike.

  • PDF

Impact Damage on Brittle Materials with Small Spheres (I)

  • Woo, Su-Chang;Kim, Moon-Saeng;Shin, Hyung-Seop;Lee, Hyeon-Chul
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.1
    • /
    • pp.30-36
    • /
    • 2003
  • Brittle materials such as glasses and ceramics, which are very weak under impact loading, show fragile failure mode due to their low fracture toughness and crack sensitivity. When brittle materials are subjected to impact by small spheres, high contact pressure occurs at the impacted surface causing local damage on the specimen. This damage is a dangerous factor in causing the final fracture of structures. In this research, the crack propagation process of soda-lime glass by the impact of small spheres is explained and the effects of several constraint conditions for impact damage were studied by using soda-lime glass; that is, the effects for the materials and sizes of impact ball, thickness of specimen and residual strength were evaluated. Especially, this research has focused on the damage behavior of ring cracks, cone cracks and several other kinds of cracks.

A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement (해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구)

  • Hwiyoung Chae ;Soondal Kwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.5-11
    • /
    • 2023
  • Economic damage is occurring due to landslides and debris flows that occur when the ground artificially created for roads or photovoltaic power generation facilities is weakened by rainfall such as torrential rain. In order to understand the stability of the artificially created ground, it is very important to check the ground information such as the compositional state and mechanical characteristics of the stratum. However, since most of the investigation sites are steep slopes or there are no access roads, it is not easy to enter the drilling equipment commonly used to check ground information and perform standard penetration tests. In this study, a dynamic cone penetration test (DCP) device using a miniaturized auger drilling equipment and an automatic drop device was developed to check the cone resistance value and the dynamic cone penetration test value and analyze the correlation with the standard penetration test value to confirm its applicability at the mountain solar power generation site. As a result, the cone resistance value is qd = 0.46 N and the dynamic cone penetration test value is Nd = 1.58 N, confirming a value similar to the results of existing researchers to secure its reliability.

The Effects of Boundary Condition in Cone Crack Formation of Soda-lime Glass by Ball Impact (볼 충격을 받는 유리의 콘크랙형성에 대한 경계조건의 영향)

  • Kim, Moon-Saeng;Heo, Jin;Lee, Hyeon-Chul;Kim, Ho-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.981-986
    • /
    • 2003
  • In order to investigate the possibility of processing of brittle material by ball impact, the effects of boundary conditions about impact damage of soda-lime glass by small spheres were evaluated experimentally. It was investigated that crack appearance developed in soda-lime glass with boundary conditions of without sealing, single-sealing and double-sealing by impact velocity. The double-sealing was most effective in the development of perfect cone than other boundary condition. In case of double-sealing condition, PVC and Polyurethane sealing were more effective in producing a perfect cone formation than other sealing materials. The impact velocity range over which perfect cones were formed was influenced by both the contact area and diameter of impact particle.