• 제목/요약/키워드: Small cone

검색결과 225건 처리시간 0.024초

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

  • Tadinada, Aditya;Marczak, Alana;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.141-147
    • /
    • 2017
  • Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose $180^{\circ}$ acquisition protocol versus a conventional $360^{\circ}$ acquisition protocol. Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: $360^{\circ}$ and $180^{\circ}$ cone-beam computed tomography (CBCT) acquisition protocols. A small-volume $180^{\circ}$ CBCT scan and a $360^{\circ}$ CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up $360^{\circ}$ CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement. Conclusion: In this ex vivo study, we found that the $180^{\circ}$ rotational acquisition was as effective as the conventional $360^{\circ}$ rotational acquisition for the preoperative evaluation of potential mini-implant sites.

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;이강희;김봉구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.782-787
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change or the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural Integrity of the material capsule called 04M-l7U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19 6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's In-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

  • PDF

소금의 고결화 현상에서 모세관 효과 (Effects of Capillary Force on Salt Cementation Phenomenon)

  • 쭝꽝훙;변용훈;엄용훈;이종섭
    • 한국지반공학회논문집
    • /
    • 제26권4호
    • /
    • pp.37-45
    • /
    • 2010
  • 기후변화로 인해 물의 증발량이 많은 지역의 지반에서는 자연적인 소금의 고결화 현상이 발생한다. 이러한 소금의 고결화 분포는 모래지반에서 모세관력에 영향을 받는다. 이 연구의 목적은 콘 관입시험, 전기전도율 측정, 사진 이미지 촬영, 비파괴 이미지 분석 그리고 탄성파에 의한 프로세스 모니터링을 이용하여 소금의 고결화 현상에 대한 모세관력의 효과를 관찰하는 것이다. 실험은 입상재료를 모형화한 글라스비즈를 소금물에 포화시킨 후, 오븐에 넣어 시료를 건조시킴으로써 고결화를 발생시켰다. 실험결과, 고결된 소금의 농도는 시료입경이 작은 경우 최상부에서 높았고, 시료입경이 큰 경우 중간 또는 하부에서 높았다. 고결된 시료에서 높은 소금농도의 위치는 해석적 방법으로 산정된 모세관 높이와 유사하였다. 본 연구에서 수행한 5가지 실험은 모세관력이 소금이 고결된 흙과 같은 입상재료의 거동에 중요한 영향을 끼치는 것을 보여준다.

Comparison of changes in the nasal cavity, pharyngeal airway, and maxillary sinus volumes after expansion and maxillary protraction with two protocols: Rapid palatal expansion versus alternate rapid maxillary expansion and constriction

  • Weitao Liu;Shaonan Zhou;Edwin Yen;Bingshuang Zou
    • 대한치과교정학회지
    • /
    • 제53권3호
    • /
    • pp.175-184
    • /
    • 2023
  • Objective: To evaluate and compare a series of volume changes in the nasal cavity (NC), nasopharynx, oropharynx, and maxillary sinuses (MS) in growing Class III patients after either rapid palatal expansion (RPE) or alternate rapid maxillary expansion and constriction (Alt-RAMEC) followed by facemask (FM) therapy, by using cone-beam computed tomography (CBCT). Methods: Forty growing Class III patients were retrospectively selected and divided into two matched groups: RPE/FM (14 females, 6 males; mean age, 9.66 ± 1.23 years) and Alt-RAMEC/FM groups (14 females, 6 males; mean age, 10.28 ± 1.45 years). The anteroposterior and vertical displacements of Point A, the volumes of the NC, nasopharyngeal, oropharyngeal, and MS were measured at different time points: pretreatment (T1), postexpansion (T2), and postprotraction (T3). Results: Both groups demonstrated significant maxilla advancement (by 1.3 mm) during expansion, with a statistically significant intergroup difference during protraction (RPE/FM, 1.1 mm; Alt-RAMEC/FM, 2.4 mm; p < 0.05) and throughout the treatment (RPE/FM, 2.4 mm; Alt-RAMEC/FM, 3.7 mm; p < 0.05). NC and nasopharyngeal airway volumes increased significantly in both groups after expansion, protraction, and treatment. The oropharyngeal and MS volumes increased in both groups after protraction and post-treatment. However, no volumetric differences were observed between the two groups. Conclusions: There was no significant difference in airway volume changes, including NC, nasopharyngeal, oropharyngeal airway, and MS, between RPE/FM and Alt-RAMEC/FM groups at different time points. Although there was significantly more forward movement after protraction in the Alt-RAMEC/FM group, the difference was deemed too small to be clinically relevant.

Radiographic patterns of periosteal bone reactions associated with endodontic lesions

  • Poorya Jalali;Jessica Riccobono;Robert A. Augsburger;Mehrnaz Tahmasbi-Arashlow
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.23.1-23.8
    • /
    • 2023
  • Objectives: The formation of new bone by periosteum due to an insult is called periosteal bone reaction (PBR). This study assessed the cone beam computed tomography (CBCT) patterns of periosteal bone reactions associated with periapical inflammatory lesion (apical periodontitis/periapical rarefying osteitis). Materials and Methods: Twenty-two small field of view CBCT images of patients with PBR were selected from a database of a private practice limited to endodontics. The volume of the periapical inflammatory lesion, the presence of cortical fenestration, the distance of the root apices to the affected cortex, and the location, pattern, and longest diameter of the periosteal reaction were recorded. Statistical analysis was performed using Wilcoxon Ranksum, Fischer's exact, Spearman Correlation Coefficient, and paired t-test. Results: In all cases, periosteal bone reaction manifested as either parallel (90.9%) or irregular (9.1%). No correlation was found between periapical inflammatory lesion volume and the periosteal reaction's longest diameter (p > 0.05). Cortical fenestration was noted in 72.7% of the cases. In addition, the findings showed that periosteal reactions were located mostly on the buccal and were present 53.8% and 100% of the time in the mandible and maxilla, respectively. Conclusions: The periosteal reactions of endodontic origin had a nonaggressive form (i.e., parallel or irregular), and none of the lesions resulted in a periosteal reaction with an ominous Codman's triangle or spicule pattern.

Factors affecting the reduction rate of odontogenic cysts after decompression based on 3-dimensional volumetric analysis

  • Sarawut Wongrattanakarn;Vorapat Trachoo;Boosana Kaboosaya;Pornkawee Charoenlarp;Net-nada Chongruangsri;Patcharapit Promoppatum
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.313-323
    • /
    • 2023
  • Purpose: This study aimed to investigate the potential factors that could affect the reduction rate of odontogenic cysts following decompression using cone-beam computed tomography (CBCT) for 3-dimensional volumetric analysis. Materials and Methods: The study sample consisted of CBCT images of 41 individuals who underwent decompression of odontogenic cysts at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, between 2010 and 2022. Preoperative and postoperative CBCT results were collected, and a volumetric analysis was conducted to evaluate the differences in the reduction rate and the percentage of volume reduction of cystic lesions based on different parameters. Correlations between these parameters were analyzed to determine associations. Results: In this study, the average time of decompression for odontogenic cysts was 316 days. Males demonstrated a higher reduction rate than females (P<0.05). The reduction rate was directly proportional to initial cyst volume, with higher reduction rates for cysts with large initial volume than those with small initial volume (P<0.05). Spearman's rank correlation coefficient indicated a weak positive correlation between the initial cyst volume and the duration of decompression. Additionally, a strong positive correlation was observed between the initial volume and the reduction rate. Conclusion: Knowledge of the reduction rate of odontogenic cysts is vital for surgeons to evaluate the duration of decompression before enucleation and to determine a definitive treatment plan. Sex and initial lesion volume had significant effects on the reduction rate.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

실대화재시험의 연소성능 예측을 위한 시뮬레이션 적용 (Applying to simulation analysis for predicting the combustion performance of Large scale fire tests)

  • 김운형;박계원;정재군;임홍순
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.86-92
    • /
    • 2008
  • On this study, modeling works using Cone tools simulation method were made for the prediction of real fire test results such as small to large scale fire tests including ISO 5660-1, EN 13823 and ISO 13784-1. For those simulation prediction, three real fire tests were performed in advance. In addition, Real data from ISO 5660-1 test were applied to this simulation modeling. Finally, the comparative analysis between Real fire tests and Simulation results were made out. Also, the Classifying evaluation by EURO Class using EN 13501-1 were taken off.

  • PDF

20대 비만여성의 유방형태 분석 (A Study on The Obese Breast Shape of 20′s Women)

  • 손희순;고태희
    • 복식문화연구
    • /
    • 제8권2호
    • /
    • pp.282-292
    • /
    • 2000
  • The purpose of this study is to provide for some basic data useful to the development of the brassieres comfortable and more suitable for obese women. The results of this study can be summarized as follows ; 1. Obese women were categorized using Rohrer index into three groups, and thereupon, their breast forms were analyzed. As a result, it was found that group 1 and 2 had similar small breasts, while group 3 had the largest size of breasts. 2. The forms of obese women's breast split, protrusion and volume, factors related with breast area and drooping, factor affecting the breast protrusion and factor defining the lower form of breast. 3. The actual breast types of obese women could be classified into cone type, protrusion type, drooping type Ⅰ and Ⅱ. The more obese a woman was, her breast tended more to droop.

  • PDF

Analysis of Fatty Acyl Groups of Diacyl Galactolipid Molecular Species by HPLC/ESI-MS with In-source Fragmentation

  • Gil, Ji-Hye;Hong, Jong-Ki;Choe, Joong-Chul;Kim, Young-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1163-1168
    • /
    • 2003
  • The structures of molecular species of galactolipids, such as monogalactosyl diacylglycerol (MGDG) and digalactosyl diacylglycerol (DGDG), isolated from wheat flour have been investigated using negative-ion electrospray ionization (ESI) mass spectrometry interfaced with high performance liquid chromatography (HPLC). According to the result of HPLC analysis, MGDG and DGDG were found to consist of mixtures of five and four molecular species, respectively. The galactolipids have been also analyzed to determine their fatty acid compositions, using HPLC/ESI-MS combined with in-source (or cone voltage) fragmentation. HPLC/ ESI-MS is very useful for one-step analysis of mixtures of galactolipids with a small sample quantity. Especially, the carboxylate anions produced in in-source fragmentations of the negative-ion of each component separated by HPLC provide valuable information on the composition of its fatty acyl chains.