• Title/Summary/Keyword: Small building

Search Result 1,692, Processing Time 0.03 seconds

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

Development of an Unit Cost Modification Model for Proper Actual Cost Data in Small Building Construction Projects (소규모 건축공사의 적정 실적공사비 단가보정 모델 개발)

  • Kim, Kang-Shik;Hyun, Chang-Taek;Hong, Tae-Hoon;Jo, Seong-Min;Mun, Hyun-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.81-89
    • /
    • 2010
  • Since 2004, the government has changedthe cost estimate system to one of an actual cost basis in order to calculate the optimum construction cost by reflecting changes in circumstance on the construction site in a timely manner. Currently, this is being applied to public construction work forover a billion won of actual cost data in estimation by contract unit cost. However, directly reflecting actual cost, which for large-sized construction work was originally an average unit cost, to a small building, entails the application of a low discount rate for the cost of materials, labor, etc. and therefore can frequently give rise to cases in which the actual cost of work performed exceeds the contract sum, which in turn causes problems such as decreased revenues, bad effectson business operation, productivity, etc. Therefore, to apply actual cost to small-sized construction work (less than a billion won), there should be a plan to modify unit cost in a manner that can reflect project scale, etc. in order to resolve the problem of unit cost application of actual cost to small-building construction projects. The unit cost modification model for proper actual construction cost in small-scale construction projects developed by this study will help to increase the relevant productivity and proper gain, preventing the aggravation of business operations. Organizations placing orders are also expected to be able to secure a more realistic construction cost in arranging the budget.

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

The Management Method for Preventing Frequent Defect about Each Inspection Part from The Data Analysis of Pre-qualification of Residential Building Reconstruction (주택 재건축 예비평가 자료분석을 통한 분야별 주요결함 발생현황 및 유지관리방안 고찰)

  • Bae, Cheol-Hak;Lee, Sung-Ok;Ji, Myoung-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2010
  • The purpose of this study is to classify defects of the residential building by analyzing the defect specified by prequalification of residential building reconstruction and to suggest the solution of the problem which can be arisen during each stage of plan, construction and maintenance. By sorting the main defects which is specified by pre-qualification of residential building reconstruction for three years from August 2006 to August 2009 into 4 catagories and analyzing the cause of the defects, we draw the way of maintenance to prevent the defects and make pleasant residential environment. The reason for the frequent defects from residential building is mainly deterioration. It occured on the finishing more than on the structure, which means that residents can find defects easier on the finishing than the structure and clear the demand for repair. The result of analyzing of pre-qualification of residential building reconstruction is that the defects mostly caused small, masonry constructed and lower apartment. The apartment which is not into legal right for maintenance naturally have more defects than the others. In conclusion, it is necessary to establish a law of obligation duty of the maintenance of small apartment.

The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity (온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성)

  • Seo, Byeong-Ryang;Kim, Shin-Do;Park, Seong-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.

The Consciousness Research for Han-Ok Construction of Community Facilities in an Apartment Housing

  • Baek, Seung-Kwan;Kim, Young-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.29-38
    • /
    • 2014
  • The Purpose of this study is to analyze the investigation of consumer's consciousness for Han-Ok construction of community facilities in an apartment housing. The contents of this study were largely composed of two parts; First was about concept and type of 'New Han-Ok type' public building. Second was about consciousness for Han-Ok construction of community facilities in an apartment housing. The result to this study is as following: 1) the concept of 'New Han-Ok type' public building should not only be defined in terms of cultural property or Han-Ok experience facilities but daily life and practical community. 2) the consciousness for Han-Ok construction of community facilities in an apartment housing was recognized affirmatively more than 75.9%. 3) the strengths of 'New Han-Ok type' public building was as following: daycare centers & small libraries & management office-use of eco materials, senior centers-traditional maintenance, community center-ease of daylight and ventilation. 4) Weaknesses of 'New Han-Ok type' public building was as following: daycare centers-security problem, senior centers-inconvenience of space, community facilities-inconvenience of facilities, small libraries-lack of storage space, management office-inconvenience of moving line. The conscious research for 'New Han-Ok type' public building should succeed for vitalizing for Han-Ok.

A Case Study on the Application of Digital-Twin to Small-size Building Remodeling Processes (디지털 트윈을 적용한 소규모 건축물 대수선 프로세스 적용 사례 연구)

  • Park, Sung-Man;Kim, Yang-Gil;Ham, Nam-Hyuk;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • The number of old buildings in Korea is increasing. According to a report from the Ministry of Land, Infrastructure and Transport, the proportion of old buildings increased from 29.0% in 2005 to 37.8% in 2009. However, the ratio of repairs to improve usability and improve the environment through problem improvement The proportion of old buildings was 72% in 2010, but decreased to 38% in 2020 and does not exceed 40%. The reason is that the difficulty of remodeling old buildings is more difficult than repairing new ones, and business estimates are difficult to predict. Accurately reflecting the current condition of a building in a repair project has a huge impact on time and budget. Accurate and detailed measurements are essential. Current repair methodologies require a lot of manpower, time and money to remodel an old building. Therefore, it is necessary to improve the remodeling methodology applied in the field. In this study proposed a Digital-Twin-based remodeling process that introduced various digital technologies such as 3D Scanning, BIM, Reverse Engineering, and Digital Fabrictation in consideration of the latest technologies used in recent construction projects. In addition, the process proposed in this study was applied to an actual small-scale building remodeling project and the results were analyzed. In addition, useful basic data were provided for the establishment of plans related to the repair process of buildings in the future.

Development of Quality Management in Small and Medium Construction Company (중 · 소규모 건설회사의 품질관리 방법 개선)

  • Lee, Geu-Sun;Yun, Yer-Wan;Yang, Keek-young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.117-124
    • /
    • 2005
  • Quality management in construction industry becomes more significant under the existing conditions such as, increasing higher demand caused by the high value of real estate and extension of the warranty period. Therefore, this study presents the alternative idea related to the current quality management conditions of small and medium construction companies, including the difficulties and problems in qualify management, in order to develop the systematical method for the quality management in small and medium construction company.

A Study on the Availability Evaluation with Failure Density Function of Equipment of Small-scale Plant (소규모 플랜트 기자재의 고장밀도함수가 가용도에 미치는 영향 평가)

  • Lee, Hongcheol;Hwang, Inju
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.33-36
    • /
    • 2016
  • The investigation on the verification of availability simulation for small-scale plant has been carried out. This study focuses on the availability variation induced by number of equipment and iteration with failure density function. The equipment classification of small-scale plant and failure type and the methodologies on Monte-Carlo simulation are established. The availability deviation with programs showed under Max. 1.7% for the case of normal function. This method could be used to availability evaluation of small-scale plant, but calibration of the failure density function is necessary for general application.

A Study on Characteristic of Apartment Houses and Understanding of Landscape Located at Small town - Centering of Jeollanamdo - (지방 소도시 아파트의 특성 및 경관 인식에 관한 연구 - 전라남도 지역을 중심으로 -)

  • Kim, Yun-Hag;Jeong, Young-Deok;Yoo, Chang-Geun;Cho, Yong-Joon;Jeong, Jin-Hwan
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2007
  • This study examines and analyzes view hindrance factors of high-storied apartment houses at small town like 'Eup' where county office locates and it is found that hindrance factors include designation of residential area and height, length and form of main building. On recognition of view, most subjects of research considered high-storied apartment houses hindered urban view and its regulation is needed. Apartment houses at small cities become main factors of hindering urban view because they were located randomly regardless of scale of city and surrounding situation, but there is no measure to control it. Accordingly, view control through enaction of regulations is urgently needed with establishment of guidelines such as height of large buildings including high-storied apartment houses, length of main building, location and regulation of exterior design.