• Title/Summary/Keyword: Small Size Tube

Search Result 132, Processing Time 0.025 seconds

The effect of 8 French catheter and chest tube on the treatment of spontaneous pneumothorax (자연기흉에 있어서 8 French 도관과 흉관의 삽입 치료 효과)

  • Kang, Yoon-Jeong;Koh, Hyoung-Gee;Shin, Jong-Wook;Lim, Seong-Yong;Choi, Jae-Sun;Yu, Ji-Hoon;Park, In-Won;Choi, Byoung-Whui;Hue, Sung-Ho;Seo, Seung-Cheon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.410-419
    • /
    • 1996
  • Background : Spontaneous pneumothorax have been managed with a variety of methods. The technique most frequently used is chest tube drainage. Small caliber catheters were first used in the management of pneumothorax complicating the percutaneous needle aspiration lung biopsy, and the try to treat spontaneous pneumothorax also has been reported. However, the value of small caliber catheters in spontaneous pneumothorax has not been fully evaluated. So, we tried to elucidate the efficacy of 8 French catheter in the management of spontaneous pneumothorax. Method : From January, 1990, to April, 1994, 44 patients with spontaneous pneumothorax treated at Chung-Ang university hospital were reviewed. The patients were sub-divide into 8 French catheter insertion group (n=21) and chest tube insertion group (n=23). We compared the presence of underlying lung disease, the extent of the collapse, the duration of indwelling catheter and complication between two groups. Results : 1) The duration of indwelling showed no significant difference between 8 French catheter group and chest tube. But, complication after insertion as subcutaneous emphysema was developed in only chest tube group. (p<0.05) 2) In the primary spontaneous pneumothorax, all case of the pneumothorax of which size was less than 50% showed complete healing with 8 French catheter insertion. Whereas the success rate in patients with large pneumothorax (more than 50%) was tended to be dependent on the age. 3) In the patients with secondary spontaneous pneumothorax who were managed with 8 French catheter, the success rate was trended to be high if the underlying disease of pneumothorax was not COPD and if the patient was young. Conclusion : These results show that 8 French catheter insertion probably was effective in the pneumothorax less than 50%, the primary spontaneous pneumothorax, young age or secondary pneumothorax not associated with COPD.

  • PDF

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

A study about structural analysis of double structured non-pneumatic wheel (이중구조를 가진 비공기압바퀴의 구조해석에 관한 연구)

  • Song, Gi-Hwan;Lee, Sang-Hun;Son, Chang-Woo;Seo, Hyoung-Jin;Seo, Tae-Il;Yoo, Wha-Wul;Park, Sung-Hak;Park, Kyung-Hoon
    • Design & Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.19-23
    • /
    • 2015
  • Non-pneumatic wheels have been widely used instead of general tube type wheels beause of many reasons, for example, wheel size, price restriction, heavy-duty problem and so on. Almost small size wheels or casters were non-pneumatic type but structural stability was not certified. This paper presents a double structured non-pneumatic wheel, called "smart caster", which consisted with inner and outer wheels connected by chips, and finite element analysis processes were conducted in order to determine important dwsign factors before actual design for mass production. For structural analysis ABAQUS was used under various boundary conditions with incrementally varied loads until 2,000N. Then structural staility was evaluated according to varied loads below ultimate stress. Generally stresses were concentrated at the lower parts of the wheel, and especially contact parts between wheel and ground. In addition, maximum stress appeared at contact parts between the wheel lower part and chips.

  • PDF

Studies on the Morphology of Smoke Particles for Each Type of Fire by Using Steady State Tube Furnace (등속공급 튜브연소로를 이용한 각 연소조건에서의 연기입자 형상 분석)

  • Goo, Jaehark
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 2014
  • Smoke from fire is a mixture of combustion gases and particles which include micro-droplets formed from condensed organic vapors and carbonaceous agglomerates. The inhalation of smoke particles causes adverse health effects, and it is prerequisite for the hazard and risk analysis of the smoke particles to know how they behaviour in the respiratory tract. The characteristics of the absorption and adsorption of toxic gases and the amount and location of the particle deposition within the respiratory tract that determine the adverse health effects are related to the morphology and the size distribution of smoke particles. In the present work, as a preliminary study for the adverse health effects of smoke particles, the morphologies of the smoke particles from combustible materials were investigated for each fire stage: smouldering, well-ventilated flaming, small under-ventilated flaming, fully-developed under-ventilated fire. The steady-state tube furnace method given in ISO/TS 19700 was used for the generation of smoke particles. The fire stages were controlled by changing furnace temperature and equivalent ratio. The morphologies were analyzed by using Transmission Electron Microscope (Bio-TEM) by collecting the particles on TEM grids put on each stage of a cascade impactor.

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Outcomes of Pulmonary Resection and Mediastinal Node Dissection by Video-Assisted Thoracoscopic Surgery Following Neoadjuvant Chemoradiation Therapy for Stage IIIA N2 Non-Small Cell Lung Cancer

  • Jeon, Yeong Jeong;Choi, Yong Soo;Lee, Kyung Jong;Lee, Se Hoon;Pyo, Hongryull;Choi, Joon Young
    • Journal of Chest Surgery
    • /
    • v.51 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • Background: We evaluated the feasibility and outcomes of pulmonary resection and mediastinal node dissection (MND) by video-assisted thoracoscopic surgery (VATS) following neoadjuvant therapy for stage IIIA N2 non-small cell lung cancer (NSCLC). Methods: From November 2009 to December 2013, a total of 35 consecutive patients with pathologically or radiologically confirmed stage IIIA N2 lung cancer underwent pulmonary resection and MND, performed by a single surgeon, following neoadjuvant chemoradiation. Preoperative patient characteristics, surgical outcomes, postoperative drainage, postoperative complications, and mortality were retrospectively analyzed. Results: VATS was completed in 17 patients. Thoracotomy was performed in 18 patients, with 13 planned thoracotomies and 5 conversions from the VATS approach. The median age was $62.7{\pm}7.9years$ in the VATS group and $60{\pm}8.7years$ in the thoracotomy group. The patients in the VATS group tended to have a lower diffusing capacity for carbon monoxide (p=0.077). There were no differences between the 2 groups in the method of diagnosing the N stage, tumor response and size after induction, tumor location, or histologic type. Complete resection was achieved in all patients. More total and mediastinal nodes were dissected in the VATS group than in the thoracotomy group (p<0.05). The median chest tube duration was 5.3 days (range, 1 to 33 days) for the VATS group and 7.2 days (range, 2 to 28 days) for the thoracotomy group. The median follow-up duration was 36.3 months. The 5-year survival rates were 76% in the VATS group and 57.8% in the thoracotomy group (p=0.39). The 5-year disease-free survival rates were 40.3% and 38.9% in the VATS and thoracotomy groups, respectively (p=0.8). Conclusion: The VATS approach following neoadjuvant treatment was safe and feasible in selected patients for the treatment of stage IIIA N2 NSCLC, with no compromise of oncologic efficacy.

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Development of Chestnut Harvesters for Small Farms (소농을 위한 밤 수확기의 개발)

  • Kang, Whoa-Seug;Guyer, Daniel
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.384-389
    • /
    • 2008
  • Three prototype chestnut harvesters were constructed and evaluated their chestnut collection ability and field efficiency. Air-lock paddle system successfully picked up all loose material, and pick up efficiency was about 56 kg/h. Power required to operate this system was evaluated to be 8.7 kW with an air flow rate of $32.6\;m^3/min$. A radial blade type blower with 0.41 m impeller diameter was considered to be a minimum size for this system. For the auger system, air was sucked into the cylinder as the hinged flat cover began to be opened by the material pushed by the auger, and the empty burrs flew back to the container through the space between auger flights and collected in the bottom of the container. It was considered to add a device to prevent air from flowing back or to use the back flowing air for separation of burrs and nuts inside the container. The venturi system could not pick up chestnuts, as they only carried part way up to the suction hose. Consideration was given to an idea that the venturi could be used as a cleaning and separation mechanism for containers filled with both empty burrs and good nuts. A minimum vacuum of 129 mm wg was required to pick up chestnuts, and the corresponding inlet air velocity was 19.3 m/s. 104 mm of vacuum, which was about 81 % of that required for nuts, was enough to pick up burrs with nuts inside. Also, empty burrs with higher moisture content recorded the same pressure as for the burrs with nuts.

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.