• Title/Summary/Keyword: Small Greenhouse

Search Result 228, Processing Time 0.037 seconds

Annual Greenhouse Gas Removal Estimates of Grassland Soil in Korea

  • Lee, Sang Hack;Park, Hyung Soo;Kim, Young-Jin;Kim, Won Ho;Sung, Jung Jong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.3
    • /
    • pp.251-256
    • /
    • 2015
  • The study was conducted to determine greenhouse gas (GHG) inventories in grasslands. After 'Low Carbon Green Growth' was declared a national vision on 2008, Medium-term greenhouse gas reduction was anticipated for 30% reduction compared to Business As Usual (BAU) by 2020. To achieve the reduction targets and prepare to enforce emissions trading (2015), national GHG inventories were measured based on the 1996 Intergovernmental Panel on Climate Change Guidelines (IPCC GL). The national Inventory Report (NIR) of Korea is published every year. Grassland sector measurement was officially added in 2014. GHG removal of grassland soil was measured from 1990 to 2012. Grassland area data of Korea was used for farmland area data in the "Cadastral Statistical Annual Report (1976~2012)". Annual grassland area corresponding to the soil classification was used "Soil classification and commentary in Korea (2011)". Grassland area was divided into 'Grassland remaining Grassland' and 'Land converted to Grassland'. The accumulated variation coefficient was assumed to be the same without time series changes in grassland remaining grassland. Therefore, GHG removal of soil carbon was calculated as zero (0) in grassland remaining grassland. Since the grassland area increases constantly, the grassland soil sinks constantly . However, the land converted to grassland area continued to decrease and GHG removal of soil carbon was reduced. In 2012 (127.35Gg $CO_2$), this removal decreased by 76% compared to 1990 (535.71 Gg $CO_2$). GHG sinks are only grasslands and woodlands. The GHG removaled in grasslands was very small, accounting for 0.2% of the total. However, the study provides value by identifying grasslands as GHG sinks along with forests.

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.

A Study on the Environmental Impact of Biological Production Facilities (대규모 생물생산 시설의 환경 영향 연구)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.5
    • /
    • pp.106-115
    • /
    • 1996
  • This study was carried out to provide fundamental data for reuse of resources and prevention of environmental pollution Actual states of environmental pollution by biological production facilities were investigated. Various pollution loads and quantity of wastes from greenhouse and animal housings estimated. In greenhouse contents of investigation were wastes of plastic cover, noise of heater and fan, air pollutant of heater, and wastes of soilless culture system, etc. In animal housings, those were actual state of livestock waste treatment and reuse, pollutant mass unit discharge, noise pollution, and malodorant, etc. The main pollutants discharged from greenhouses were wastes of plastic cover, rockwool, and waste fluid of nutrient solution. Developments of waste disposal methods for plastic cover and rockwool are required. And recycle technique of nutrient solution for soilless culture should be developed and propagated. With the buildup of legal control, pollutant mass discharged from livestock wastes are, on the decrease. The other side, reuse of livestock excreta increased. Most animal housings are located near the dwelling house. Malodorant and noise from animal housings have bad effects on the rural living conditions. So developments of integrated complex for small scale livestock farms are required.

  • PDF

Measurement of Energy Efficiency For the Reduction of Greenhouse Gases (온실가스 감축에 대비한 에너지 효율의 계측)

  • Kang, Sang-Mok
    • Journal of Environmental Policy
    • /
    • v.11 no.1
    • /
    • pp.75-97
    • /
    • 2012
  • The purpose of the paper is to estimate the functions of the energy input efficiency and the energy intensity efficiency, and measure their energy efficiencies for the reduction of greenhouse gases focusing on OECD countries. The efficiency of the traditional energy intensity was rarely connected with the energy efficiencies of the stochastic frontier function. It seems that the energy efficiency by the function of energy input efficiency sensitively responds to the order of GDP, capital stock, labor, and energy input quantity as explanatory variables. In the future, we need to reduce energy quantities by the optimal mix of inputs, and pursuit low-carbon economic growth through the production of the goods consuming small energy.

  • PDF

Conversion of $CO_2$ and $CH_4$ to Syngas by Making Use of Microwave Plasma Torch (전자파 플라즈마 토치를 이용한 이산화탄소와 메탄의 Syngas 합성)

  • Dong Hun, Shin;Yong Cheol, Hong;Han Sup, Uhm
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.11a
    • /
    • pp.195-200
    • /
    • 2004
  • Carbon dioxide ($CO_2$) and methane (CH$_4$) are two major greenhouse Bases. $CO_2$is a stack gas of many industrial processes and the main product of the hydrocarbon combustion. There is recent research interest on the synthesis gas (syngas) formation from $CO_2$ and CH$_4$, via the following reaction: CH$_4$+$CO_2$longrightarrow 2H$_2$+$CO_2$, in order to reduce the greenhouse effects and to synthesize various chemicals, Preliminary experiments were conducted on the conversion of $CO_2$ and CH$_4$ to syngas by making use of a microwave plasma torch at atmospheric pressure. Conversion rates of $CO_2$and CH$_4$ to hydrogen (H$_2$), carbon monoxide (CO) and higher hydrocarbons were investigated using Gas Chromatography (GC) and Fourier Transform Infrared (FTIR). The experimental data indicate that the main products were H$_2$, CO and small amount of higher hydrocarbons, such as ethylene (C$_2$H$_4$).

  • PDF

Occurrence of Black Mold on Sweet Pepper Fruits Caused by Alternaria alternata in Korea

  • Wan-Gyu Kim;Gyo-Bin Lee;Sun-Im Yun;Jae-Taek Ryu
    • Research in Plant Disease
    • /
    • v.30 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • In July 2022 and 2023, black mold symptoms were observed sporadically on fruits of sweet pepper (Capsicum annuum) plants grown in a greenhouse located in Suwon, Korea. The incidence of black mold on the fruits was 5-24% (average 14.8%) in variety SP-504 (yellow and elongate type) and 1-8% (average 5%) in variety SP-505 (red and round type) investigated. Four single-conidium isolates of Alternaria sp. obtained from the diseased fruits were identified as Alternaria alternata based on the morphological characteristics and molecular phyogenetic analyses. The isolates were tested for pathogenicity to sweet pepper fruits of varieties SP-504 and SP-505 through artificial inoculation. The isolates mostly induced large lesions on fruits of the two varieties in the wound inoculation, but only two isolates small lesions on fruits of the variety SP-504 in the non-wound inoculation. No lesions formed on fruits of the variety SP-505 in the non-wound inoculation. The pathogenicity tests revealed that susceptibility of sweet pepper fruits to the disease differs between the varieties. The symptoms induced by pathogenicity tests with the isolates were similar to those observed on fruits from the greenhouse investigated. This is the first report of A. alternata causing black mold on sweet pepper fruits in Korea.

Determining the Maximum Capacity of a Small Wind Turbine System Considering Live Loads of Buildings (건물의 활하중을 고려한 소형풍력발전시스템의 최대 설비용량 선정기법)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Due to environmental issues such as global warming, the reduction of greenhouse gas emissions has become an inevitable measure to be taken. Among others, the building sector accounts for 50% of total carbon dioxide emissions, which is significantly high. Therefore, in order to reduce carbon dioxide emissions of the buildings, improving the energy efficiency by utilizing wind power among renewable energy sources is recommended. In case of buildings in the planning stage, it is possible to take the load of wind power generation systems into consideration when determining installed capacity. Already completed buildings, however, should be connected to small wind electric systems according to the live loads of the buildings based on the architectural design criteria. In order to connect to a building that has already been completed, it is necessary to consider the load of the small wind electric system as well as the live load of building. In addition, we need to generate the maximum electricity possible by determining the maximum installed capacity in a small area. In this paper, we propose the method for determining maximum capacity for building integrated small wind electric systems, which takes into account the considerations associated with connecting small wind electric systems to completed buildings. This can be developed into a system linked to solar power, which makes it possible to improve the energy independence of the building. In addition, carbon dioxide reduction by improving energy efficiency is expected.

Evaluation and Comparison Study of Carbon Footprint of High School Students: Focused on Commute to School in Big, Middle, Small Size City (국내 고등학생들의 탄소발자국 산정과 비교에 관한 연구: 대.중.소도시 통학패턴을 중심으로)

  • Yeo, In-Ho;Kim, Jun-Beum;Kang, Suk-Kyo;Kim, Jin-Beum
    • Hwankyungkyoyuk
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • The goal of this study, as an effort to reduce national greenhouse gas (GHG) emissions, is to calculate the carbon footprint of students based on the commute pattern of high school students in big (Seoul), middle (Suwon) and small (Icheon) size city. By conducting a survey, the commute pattern and method of students as well as students' carbon footprint were evaluated. As a result, the carbon footprint of the high school student in Icheon ($1.698kgCO_2$) had 2~3 times higher than student's carbon footprint in Seoul ($0.623kgCO_2$) and Suwon ($0.699kgCO_2$). One of the reasons for the different carbon footprint result between big and small city was whether the public pedestrian facilities and a bicycle path or not. Based on our research results, we pointed out the problems and suggested some ways to reduce carbon footprint of students.

  • PDF

Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production (능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상)

  • Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Dong-Soo;Yang, Hee-Jung;An, Yeong-Seop;Kim, Won-Kyoung;Kim, Jeong-Hyeon;Park, Dong-Eul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

A Study on Greenhouse Gas Removals Estimation of a Small Scale Afforestation/reforestation CDM Pilot Project in Goseong, Gangwon Province (강원도 고성군 소규모 신규조림/재조림 CDM 시범사업의 온실가스 감축량 산정 연구)

  • Kim, Jiyeon;Lee, Sue Kyoung;Noh, Nam Jin;Yoon, Tae Kyung;Han, Saerom;Cui, Guishan;Lee, Woo-Kyun;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.3
    • /
    • pp.398-406
    • /
    • 2013
  • Afforestation/reforestation (A/R) clean development mechanism (CDM) is the only forestry-based activities allowed under the Kyoto protocol. This study was conducted to develop a methodology to estimate greenhouse gas (GHG) removals of a small scale A/R CDM pilot project in Goseong, Gangwon Province, Korea. AR-AMS0001 was applied as a methodology and selected tree species were Pinus koraiensis, Larix kaempferi, and Betula platyphylla for total area of 75.0 ha. To improve the accuracy on the GHG removals estimation, selection of the baseline scenario and carbon pools and stratification of the project site were conducted. Based on the developed methodology, net anthropogenic GHG removals were estimated as actual net GHG removals, subtracted by baseline net greenhouse gas removals and leakage. As a result, anthropogenic GHG removals of the project were 12,415 ton $CO_2-e$ and 165.5 ton $CO_2-e/ha$. This project is the first A/R CDM in domestic site and could enhance the technical accuracy of the GHG removals estimation by using countryspecific data reflecting the site condition.