• 제목/요약/키워드: Slush

검색결과 30건 처리시간 0.031초

소형 슬러시 제조기 증발기에서 슬러시 형성시 전열 특성 (Heat Transfer Characteristics During Slush Formation in the Evaporator of a Small Slush Maker)

  • 최용민;김도영;김내현;이을종;김수환;변호원
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.643-648
    • /
    • 2009
  • Tests were conducted to obtain heat transfer coefficients during slush formation from 10% sucrose solution. The slush was made by scraping the ice formed on the cylinder. Cold brine was supplied inside of the evaporator cylinder to cool the outer surface. Below a certain brine temperature, which was $-5^{\circ}C$ in this study, the solution was supercooled, and suddenly turned into ice crystals. During slush formation, the heat transfer coefficient oscillated significantly, due to periodic removal of ice chunk form the surface. The average heat transfer coefficient during slush formation was 40~70% higher than that obtained during single phase cooling. The heat transfer coefficient was also affected by the brine temperature with increasing heat transfer coefficient at higher brine temperature.

장주기/대용량 수소저장을 위한 액체/고체기반 Slush 수소의 저장 비용 분석 (An Economic Analysis on Slush Hydrogen Containing Liquid and Solid Phase for Long-Term and Large-Scale Storage)

  • 박성호;이창형;류주열;황성현
    • 한국수소및신에너지학회논문집
    • /
    • 제33권3호
    • /
    • pp.247-254
    • /
    • 2022
  • Slush hydrogen containing liquid and solid hydrogen is expected to achieve zero boil-off by suppressing boil-off gas because heat of fusion for solid absorbe the heat ingress from atmosphere. In this paper, quantitative analysis on storage cost considering specific energy consumption between 1,000 m3 class liquid hydrogen storage system with re-liquefaction and slush hydrogen storage system during equivalent zero boil off period. Even though approximately 50% of total storage capacity should be converted into solid phase during the initial cargo bunkering, total energy consumption to convert into slush hydrogen is relatively 25% less than re-liquefaction energy for boil off hydrogen during zero boil off period. That's because energy consumption of slush phase change take up only 1.8% of liquefaction energy. moreover, annual revenue requirement including CAPEX, OPEX and electric cost for slush hydrogen storage could be more reduced approximately 32.5% than those of liquid hydrogen storage and specific energy storage cost ($/kg-H2) could also be lowered by about 41.7% compared with liquid hydrogen storage.

소형 슬러시 제조기의 전열현상에 관한 연구 (Heat Transfer Characteristics of Small Slush Maker)

  • 김도영;김내현;오왕규;최용민;변호원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.346-350
    • /
    • 2008
  • Tests were conducted to obtain heat transfer coefficients during slush formation from 10% sucrose solution. The slush was made by scraping the ice formed on the cylinder. Cold brine was supplied inside of the cylinder to cool the outer surface. Below a certain brine temperature, which was $5^{\circ}C$ in this study, the solution was supercooled, and suddenly turned into ice. The super-cooling increases as the brine temperature increased. During slush formation, the heat transfer coefficient oscillated significantly, due to periodic removal of ice chunk form the surface. The average heat transfer coefficient during slush formation was approximately twice of that obtained during single phase cooling. The heat transfer coefficient was also affected by the brine temperature with increasing heat transfer coefficient at lower brine temperature.

  • PDF

장주기/대용량 저장을 위한 액체/고체(Slush) 수소 생산 장치의 해외기술 동향분석 (Technical Review on Liquid/Solid (Slush) Hydrogen Production Unit for Long-Term and Bulk storage)

  • 이창형;류주열;손근;박성호
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.565-572
    • /
    • 2021
  • Hydrogen is currently produced from natural gas reforming or industrial process of by-product over than 90%. Additionally, there are green hydrogens based on renewable energy generation, but the import of green hydrogen from other countries is being considered due to the output variability depending on the weather and climate. Due to low density of hydrogen, it is difficult to storage and import hydrogen of large capacity. For improving low density issue of hydrogen, the gaseous hydrogen is liquefied and stored in cryogenic tank. Density of hydrogen increase from 0.081 kg/m3 to 71 kg/m3 when gaseous hydrogen transfer to liquid hydrogen. Density of liquid hydrogen is higher about 800 times than gaseous. However, since density and boiling point of liquid hydrogen is too lower than liquefied natural gas approximately 1/6 and 90 K, to store liquid hydrogen for long-term is very difficult too. To overcome this weakness, this paper introduces storage method of hydrogen based on liquid/solid (slush) and facilities for producing slush hydrogen to improve low density issue of hydrogen. Slush hydrogen is higher density and heat capacity than liquid hydrogen, can be expected to improve these issues.

A study on the practical measures of the corporate crime investigation -Focusing on white color crime-

  • Nam, SeonMo
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.96-100
    • /
    • 2020
  • In this paper, I try to help the business operation so that they could continue the desirable operation despite the unfavorable conditions. It is important to reinforce for corporate growth various support measures to generate profits. However, if they are involved in criminal activities such as slush fund creation, they will have to deal with them separately. As a result, To raise awareness helps to keep the company running. Recently, the companies are in a poor condition due to overseas migration. If a company does not create profits by doing business, it is a burden to continue operating and it will eventually be hard to support and destroy. The corporate crime and white-collar crime are mostly similar types, mainly because they occur in the industry. The corporate crime proceeds throughout the company and ultimately translates into corporate profits. The white-collar crime, on the other hand, is a profitable part of the individual. In the process of generating profits, the purpose and management method of slush funds is an important issue in judging whether illegal immorality of business is intended or not. In addition, in the case of the corporate crime, it seems necessary to identify the types of slush fund raising activities in addition to the investigations of the accomplices and clinical investigations, and to apply efficient investigation methods on a case-by-case basis. At present, many companies frequently migrate overseas due to the influence of domestic regulations. In this process, if it is involved in crime such as a borrowing accounts or the purpose of slush fund creation should be treated separately.

개심술후 합병되는 횡격신경마비에 관한 임상적 고찰 (A Clinical Review of Phrenic Nerve Paralysis associated with the Use of Iced Slush for Topical Hypothermia during Cardiac Surgery)

  • 이재성
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.483-488
    • /
    • 1987
  • Phrenic nerve injury has been reported with the use of iced slush for topical cardiac hypothermia. A review of the preoperative and the postoperative chest roentgenograms was performed to detect phrenic nerve injury in patients undergoing cardiac operation with the use of iced slush for topical hypothermia from January, 1985 to June, 1987. The reviewed series included 45 patients who had undergone valve replacement. In this review, the injured site of phrenic nerve was left in 13 cases, right in 1 case and the overall incidence of phrenic nerve paralysis following open heart surgery was 31%. Compared to the incidence of phrenic nerve paralysis in the control group [without pericardial insulation] [406, 12 cases/30 cases], that in the group of patients receiving pericardial insulation [13.3%, 2 cases/15 cases] was lower, but there was no statistical significance. The initial time that diaphragmatic paralysis developed was mean 3.5 days [range 1-8 days] postoperatively and the recovery time of the paralysis was mean 4.7 months [range 0.5-10.5 months] postoperatively.

  • PDF

Spherocarb와 Sucrose Char에 대한 비표면적과 세공부피의 측정 (Surface Area and Micropore Volume Measurements of Spherocarb and Sucrose Char)

  • 김학희;박상진
    • 공업화학
    • /
    • 제5권1호
    • /
    • pp.105-113
    • /
    • 1994
  • Spherocarb와 Sucrose Char에 의해 흡착된 질소가스의 양은 온도를 77K에서 184K가지 일정하게 유지시키면서, 상대적 압력의 함수로서 측정되었다. 다른 온도에서의 Isotherm은 흡착제를 일정한 온도에서 유지시키면서, 액화질소, iso-펜탄, n-펜탄, 에틸알코올과 iso-프로필 알코올의 Slush bath를 사용하여 얻어졌다. 이 연구의 목적은 BET와 D-R 같은 흡착모델을 사용하여, 실험적 데이타를 분석함으로써, 비표면적과 세공부피에 대한 정보를 얻는데 있다.

  • PDF

흰쥐의 적출된 작업성 심장에서 허혈성 심정지시 국소냉각법이 심근보호에 미치는 영향 (Effect of Topical Hypothermia on Myocardial Protection from Ischemia - Experimental study using isolated rat heart perfusion technique-)

  • 최종범
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.231-239
    • /
    • 1988
  • Currently numerous methods are in use for myocardial hypothermia as a myocardial preservation modality for cardiac operation. During cardiac ischemia after crystalloid cardioplegia[4C GIK solution], topical cold saline[Group I, a=9], topical ice slush[Group II, n=9] and topical ice chip[Group III, a=10] have been compared for myocardial surface cooling in the isolated rat heart model of cardiopulmonary bypass. During postischemic period, hemodynamic functions[aortic flow, coronary flow, peak aortic pressure and heart rate], biochemical enzymatic activities and cellular injuries with electron microscope were evaluated in this isolated rat heart perfusion model. Postischemic aortic flow, cardiac output and peak aortic pressure in Group I and Group II recovered better than Group III.[p< 0.05] Postischemic creatine kinase and lactate dehydrogenase leakages in Group II and Group III increased more than Group l and postischemic mitochondrial swelling in Group III was more severe than Group I, and Group II.[p< 0.05] These results suggest that topical cold saline was the better method than topical ice slush or topical ice chip as a myocardial preservation modality in the isolated rat heart model of cardiopulmonary bypass.

  • PDF