• Title/Summary/Keyword: Slow strain rate test

Search Result 51, Processing Time 0.027 seconds

A Study on Stress Corrosion of Al-8ti-1B Alloys by Mechanical Alloying (기계적 합금화한 Al-8Ti-1B 합금의 응력부식에 관한 연구)

  • 김기주;강성군;백영남
    • Journal of the Korean institute of surface engineering
    • /
    • v.27 no.4
    • /
    • pp.215-222
    • /
    • 1994
  • The role dispersoids has been studied in a number of researches as a key point for the high strength application of dispersion strengthened aluminum alloy. The mechanical alloying(MA) process with high mechanical properties of dispersion strengthened MA Al-8Ti-1B alloys were invested in order to evaluate their stress corrosion cracking(SCC) application. SCC properties of the mechanically alloyed Al-8Ti-1B were studied using slow strain rate test(SSRT). In this study Al-8Ti-1B alloy were more susceptible to SCC in solutions of pH=2.01 and 13.2 than pH=6.81 solution. In this study Al-8Ti-1B alloys by MA had more SCC resistance than Al-8Ti alloys or Al 7075-T73 alloys. So Al-8Ti-1B alloys by MA had more resistance in SSRT SCC susceptinility test than any other above alloying metals.

  • PDF

The Study on the Freezing Methods and the Cryoprotectants for Rat Embryo Preservation (Rat 수정란의 동결보존에 있어 동결속도 및 동해방지제에 관한 연구)

  • 유준희;이재근
    • Korean Journal of Animal Reproduction
    • /
    • v.8 no.1
    • /
    • pp.22-28
    • /
    • 1984
  • This experiment was carried out to investigate effects of DMSO or ethylene glycol as a cryopotectant and of freezing methods on survival rate of forozen-thawed rat 2-cell embryos by morphological observation. 2-cell embryos were recovered from oviducts of Sprague Dawley females mated with males of same strain on day 2 of pregnancy after inducing superovulation by intrapertioneal injection of PMSG and HCG. In slow freezing and thawing groups, embryos were frozen to -79$^{\circ}C$ or -196$^{\circ}C$ in a glass test tube containing 0.2ml PBI with 1.5M DMSO or 1.2M ethylene glycol at a rate of 0.3-1.0C/min. and thawed slowly. When samples were frozen to -79$^{\circ}C$, higher survival rate was obtained in the medium containing DMSO (43.9%) than ethylene glycol (41%). And similar result was obtained (32.5% in DMSO vs. 31.4% in ethylene glycol) when samples were frozen. In rapid freezing and thawing groups, embryos were frozen to -79 or -196$^{\circ}C$ in a glass test tube containing 0.2ml of PBI with 1.5M DMSO or 1.2M ethylene glycol by rapid cooling, and thawed rapidly. When samples were frozen to -79$^{\circ}C$, 1.5M DMSO (13.2%) was more effective than 1.2M ethylene glycol (6.1%). When the storage temperature was -196$^{\circ}C$, survival rates were 9.8% in 1.5M and 5.4% in 1.2M ethylene glycol.

  • PDF

A Study on the Corrosion Rehavior and Mechanical Property by SSRTTest of Welding Part of RE36 Steel for Marine Structure (해양구조물 RE36강의 용접부 부식거동 및 SSRT법에 의한 기계적 특성에 관한 연구)

  • 김종성;김진경;김종호;이명훈;김영식;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.460-469
    • /
    • 2000
  • A study on the corrosion behavior of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential and corrosion current density measurement of weld metal(WM), base metal (BM) and heat affected zone(HAZ), Al anode generating current and Al anode weight loss quantity in case of cathodic protection. And we carried out slow strain rate test(SSRT) in order to research mechanical properties such as stress at maximum load, percent strain, time to fracture and strain to failure ratio etc and to find out limiting cathodic polarization potential for hydrogen embrittlement with applied cathodic polarization potential. Hardness of HAZ part was the highest among those three parts and also galvanic corrosion susceptibility was the highest in HAZ part among those three parts due to the lowest corrosion potential than other parts. However corrosion current density was the highest in WM part among those three parts. And the optimum cathodic polarization potential showing the best mechanical properties obtained by SSRT method with applied constant cathodic potential was from - 770mV to - 875mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement on the mechanical properties was under - 900mV(SCE).

  • PDF

The Slow Strain Rate Dependence of Zircaloy-4 Cladding Tube in Iodine Atmosphere (I) (요드분위기에서 지르칼로이 피복재의 저변형율속도 의존성(I))

  • Choi, Y.;Kang, Y.H.;Ryu, W.S.;Rim, C.S.
    • Nuclear Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.211-215
    • /
    • 1985
  • The effects of temperature and strain rate on the I-SCC behaviors of Zircaloy-4 were investigated by constant load test at 30$0^{\circ}C$ and constant elongation rate test at 300, 350 and 40$0^{\circ}C$ in 3.34mg $I_2$/㎤. The results showed that I-SCC susceptibility increased as the strain rate decreased or the temperature increased. The empirical relation between the stress and the time to failure at 30$0^{\circ}C$ was given by 1/ $t_{f}$∝exp (0.3$\sigma$/$\sigma$$_{UTS}$-31.5) When the I-SCC susceptibility was expressed by the ratio of fracture energy in iodine atmosphere to that in the inert atmosphere, severe I-SCC susceptibility was found near 7.6$\times$10$^{-6}$ sec at 30$0^{\circ}C$ and the maximum point of I-SCC susceptibility tended to shift to the higher strain rate with increasing the temperature. The quasi-cleavage fracture was observed in I-SCC fracture surface. From these results, it was certain that the film repture step was involved as an important process in the I-SCC mechanism of Zircaloy-4.4.

  • PDF

Comparison of hydrogen embrittlement resistance between 2205 duplex stainless steels and type 316L austenitic stainless steels under the cathodic applied potential (음극 인가전위 하에서 type 2205과 type 316L의 수소취성 저항성)

  • Seo, Dong-Il;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.237-244
    • /
    • 2016
  • 2205 duplex stainless steels have been used for the construction of the marine environment, because of their excellent corrosion resistance and high strength. However, the resistance to hydrogen embrittlement (HE) may be less than that of 316L austenitic stainless steel. The reason why 316L stainless steels have better resistance to HE is associated with crystal structure (FCC, face centered cubic) and the higher stacking faults energy than 2205 duplex stainless steels. Furthermore 2205 stainless steels with or without tungsten were also examined in terms of HE. 2205 stainless steels containing tungsten is less resistible to HE. It is because dislocation tangle was formed in 2205 duplex stainless steels. Slow strain-rate tensile test (SSRT) was conducted to measure the resistance to HE under the cathodic applied potential. Hydrogen embrittlement index (HEI) was used to evaluate HE resistance through the quantitative calculation.

Stress Corrosion Cracking Behavior of Cold Worked 316L Stainless Steel in Chloride Environment

  • Pak, Sung Joon;Ju, Heongkyu
    • Journal of Korea Foundry Society
    • /
    • v.40 no.5
    • /
    • pp.129-133
    • /
    • 2020
  • The outcomes of solution annealing and stress corrosion cracking in cold-worked 316L austenitic stainless steel have been studied using x-ray diffraction (XRD) and the slow strain rate test (SSRT) technique. The good compatibility with a high-temperature water environment allows 316L austenitic stainless steel to be widely adopted as an internal structural material in light water reactors. However, stress corrosion cracking (SCC) has recently been highlighted in the stainless steels used in commercial pressurized water reactor (PWR) plants. In this paper, SCC and inter granular cracking (IGC) are discussed on the basis of solution annealing in a chloride environment. It was found that the martensitic contents of cold-worked 316L stainless steel decreased as the solution annealing time was increased at a high temperature. Moreover, mode of SCC was closely related to use of a chloride environment. The results here provide evidence of the vital role of a chloride environment during the SCC of cold-worked 316L.

Physiological and Ecological Characteristis of Hemolytic Vibrios and Development of Sanitary Countermeasure of Raw Fisheries Foods. 2. Physiological and Psychrotrophic Characteristics of Vibrio mimicus SM-9 Isolated from sea Water (용혈독소를 생산하는 기수성 비브리오균의 생리.생태적 특성과 수산식품의 위생대책 2. 해수에서 분리된 vibrio mimicus SM-9의 생리적 특성 및 저온내성)

  • 장동석;김신명;박욱연;박미연;김영만
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 1997
  • Vibrio mimicus is a closely related species with V. cholerae, and has been reported to be associated with gastrointestinal infections. Although extraintestinal infections of these vibrios have also been reported in Japan and Southeast Asia. But little research papers on V. mimicus was reported in Korea. Therefore, we tried to isolate V. mimicus from the environmental sea water from April to July in Pusan, Korea. Among the isolated strains, we selected the strongest hemolytic strain and then named V. mimicus SM-9. In this paper, we checked the antibiotic susceptibility and psychrotrophic characteristics of the isolated strain. Hemolytic activity of the hemolysin produced by the isolated strain was also measured. V. mimicus was not detected from the sea water samples in April and May, but its detection rate was relatively high in June and July in Pusan, Korea. The bacteriological characteristics of V. mimicus SM-9 were Gram-negative rods, motile, oxidase positive, Voges-Proskauer negative and sucrose negative. In 23 kinds of antibiotics susceptibility test, V. mimicus SM-9 showed susceptibility to the most of antibiotics submitted while it was resistive against lincomycin, oxacillin, rifampin and vancomycin. Hemolytic activity of the hemolysin produced by V. mimicus SM-9 was highest in stationary phase of the growth curve in BHI broth at 37$^{\circ}C$ and its activity was reached 18 HU per $m\ell$ of culture supernatant. For checking the psychrotrophic property of V. mimicus SM-9, the decreasing rate of the strain in phosphate buffer solution and yellowtail flesh homogenate was examined during the storage at 4, 0, -4 and -2$0^{\circ}C$. The decreasing rates of the selected strain stored in phosphate buffer solution were greater than those in fish homogenate. Decreasing rates of V. mimicus SM-9 stored in phosphate buffer solution were not significantly different by the storage temperatures. The viable cell counts of the strain were decreased as 5 log cycles after 120 hours at all the tested temperatures. While decreasing numbers of the strain in fish homogenates were 2*4 log cycles after 120 hours. The decreasing pattern of the strain numbers were very slow after 200 hours at all the stored temperatures.

  • PDF

Effects of Zn-Flash Coating on Hydrogen Evolution, Infusion, and Embrittlement of Advanced-High-Strength Steel During Electro-Galvanizing (Zn-Flash 코팅 처리가 전기아연도금 시 초고강도 강재의 수소 발생, 유입 및 취화 거동에 미치는 영향)

  • Hye Rin Bang;Sang Heon Kim;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.341-350
    • /
    • 2023
  • In the present study, effects of a thin Zn-flash coating on hydrogen evolution, infusion, and embrittlement of advanced high strength steel during electro-galvanizing were examined. The electrochemical permeation technique in conjunction with impedance spectroscopy was employed under applied cathodic polarization. Moreover, a slow-strain rate test was conducted to evaluate loss of elongation (i.e., indicative of hydrogen embrittlement (HE)) and examine fracture surfaces. Results showed that the presence of a thin Zn-flash coating, even when it was not distributed uniformly, reduced hydrogen evolution rate and substantially impeded infusion of hydrogen into the steel substrate. This was primarily due to a hydrogen overvoltage on Zn coating and trapping of hydrogen at the interface of Zn coating/flash coating/steel substrate. Consequently, the sample with flash coating had a smaller HE index than the sample without flash coating. These results suggest that a thin Zn-flash coating could be an effective technical strategy for mitigating HE in advanced high-strength steels.

ACOUSTIC EMISSION CHARACTERISTICS OF STRESS CORROSION CRACKS IN A TYPE 304 STAINLESS STEEL TUBE

  • HWANG, WOONGGI;BAE, SEUNGGI;KIM, JAESEONG;KANG, SUNGSIK;KWAG, NOGWON;LEE, BOYOUNG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.454-460
    • /
    • 2015
  • Acoustic emission (AE) is one of the promising methods for detecting the formation of stress corrosion cracks (SCCs) in laboratory tests. This method has the advantage of online inspection. Some studies have been conducted to investigate the characteristics of AE parameters during SCC propagation. However, it is difficult to classify the distinct features of SCC behavior. Because the previous studies were performed on slow strain rate test or compact tension specimens, it is difficult to make certain correlations between AE signals and actual SCC behavior in real tube-type specimens. In this study, the specimen was a AISI 304 stainless steel tube widely applied in the nuclear industry, and an accelerated test was conducted at high temperature and pressure with a corrosive environmental condition. The study result indicated that intense AE signals were mainly detected in the elastic deformation region, and a good correlation was observed between AE activity and crack growth. By contrast, the behavior of accumulated counts was divided into four regions. According to the waveform analysis, a specific waveform pattern was observed during SCC development. It is suggested that AE can be used to detect and monitor SCC initiation and propagation in actual tubes.

A Study on the Post-Weld Heat Treatment Effect Affecting Corrosion Behavior and Mechanical Property of Welding Part of RE36 Steel for Marine Structure (해양구조물용 RE36강 용접부의 부식거동 및 기계적 특성에 미치는 용접후 열처리 효과에 관한 연구)

  • 김성종;문경만
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.65-74
    • /
    • 2001
  • A study on the corrosion behavior in case of As-welded and PWHT temperature 55$0^{\circ}C$ of welding part of RE36 steel for marine structure was investigated with parameters such as micro-Vickers hardness, corrosion potential measurement of weld metal(WM), base metal(BM) and heat affected zone(HAZ), both Al anode generating current and Al anode weight loss quantity under sacrificial anode cathodic protection conditions. And also we carried out slow strain rate test(SSRT) in order to research both limiting cathodic polarization potential for hydrogen embrittlement and optimum cathodic protection potential as well as mechanical properties by post-weld heat treatment(PWHT) effect. Hardness of HAZ was the highest among three parts(WM, BM and HAZ) and the highest galvanic corrosion susceptibility was HAZ. And the optimum cathodic polarization potential showing the best mechanical properties by SSRT method was from -770mV to -875mV(SCE). In analysis of SEM fractography, applied cathodic potential from -770mV to -875mV(SCE) it appeared dimple pattern with ductile fracture while it showed transgranular pattern (Q. C : quasicleavage) under -900mV(SCE). However it is suggested that limiting cathodic polarization potential indicating hydrogen embrittlement was under -900mV(SCE).

  • PDF