• 제목/요약/키워드: Slow Scan

검색결과 52건 처리시간 0.03초

Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA)

  • 손윤희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF

퍼지인식도와 세션패턴 기반의 비정상 탐지 메커니즘 (Anomaly Detection Mechanism based on the Session Patterns and Fuzzy Cognitive Maps)

  • 류대희;이세열;김혁진;송영덕
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권6호
    • /
    • pp.9-16
    • /
    • 2005
  • 최근 인터넷 이용자들이 급격하게 증가하고 있으며, 초보수준의 일반 네트워크 사용자들도 인터넷상의 공개된 해킹 도구들을 사용하여 고도의 기술을 요하는 침입이 가능하여 해킹 문제가 더욱 심각해지고 있다. 해커들이 침입하기 위하여 취약점을 알아내려고 의도하는 다양한 형태의 침입시도를 사전에 탐지하여 침입이 일어나는 것을 미리 방어할 수 있는 침입시도탐지가 적극적인 예방 차원에서 더욱 필요하다. 기존의 포트 스캔이나 네트워크 취약점 공격에 대응하기 위한 네트워크 기반의 비정상 침입시도 탐지 알고리즘은 침입시도함지에 있어 몇 가지 한계점을 갖고 있다. 기존 알고리즘은 Slow Scan, Coordinated Scan을 할 경우 탐지할 수 없다는 것이다. 따라서 침입시도 유형에 제한을 받지 않고 침입시도에 관한 다양한 형태의 비정상 접속을 효과적으로 탐지할 수 있는 새로운 개념의 알고리즘이 요구된다. 본 논문에서는 세션 패턴과 탐지 오류율을 규칙기반으로 하는 침입시도 탐지알고리즘(Session patterns & FCM Anomaly Detector : SFAD)을 제안한다.

  • PDF

세션 패턴을 이용한 네트워크기반의 비정상 탐지 모델 (Anomaly Detection Model based on Network using the Session Patterns)

  • 박수진;최용락
    • 정보처리학회논문지C
    • /
    • 제11C권6호
    • /
    • pp.719-724
    • /
    • 2004
  • 현재는 인터넷 이용자들이 급격하게 증가하고 있으며, 초보수준의 일반 네트워크 사용자들도 인터넷상의 공개된 해킹 도구들을 사용하여 고도의 기술을 요하는 침임이 가능해졌기 때문에 해킹 문제가 더욱 심각해지고 있다. 해커들이 침입하기 위하여 취약점을 알아내려고 의도하는 다양한 형태의 침입시도들을 탐지하여 침입이 일어나는 것을 사전에 방어할 수 있는 침입시도탐지가 적극적인 예방 차원에서 더욱 필요하다. 기존의 포트 스캔이나 네트워크 취약점 검색 공격에 대응하기 위한 네트워크 기반의 비정상 침입시도 탐지 알고리즘들은 침입시도탐지에 있어 몇 가지 한계점을 갖고 있다. 기존 알고리즘들의 취약성은 Slow Scan과 Coordinated Scan을 한 경우 탐지한 수 없다. 따라서, 침입시도 유형에 제한을 받지 않고 침입시도에 관한 다양한 형태의 비정상 접속을 효과적으로 탐지할 수 있는 새로운 개념의 알고리즘이 요구된다. 본 논문에서는 평상시 정상적인 서비스 패턴을 가지고 그 패턴과 다른 비정상 서비스 패턴이 보이면 이를 침입시도로 탐지하는 개념의 SPAD(Session Pattern Anomaly Detector) 기법을 제안한다.

늦은 용액증발법으로 제작한 유기단결정 para-toluene sulfonate의 비선형 광학상수 측정 (Measurement of nonlinear optical constant of organic single crystal para-toluene sulfonate prepared by slow solution evaporation method)

  • 황보창권
    • 한국광학회지
    • /
    • 제9권2호
    • /
    • pp.76-85
    • /
    • 1998
  • 서서히 용액을 증발시키는 늦은 용액증발법을 이용하여 유기단결정 p-toluene sulfonate(PTS) 덩어리와 박막을 제작하였다. 유기 단결정 PTS 덩어리는 Z-scan 방법을 이용하여 1600 nm, 95fs 레이저 광으로 3차와 5차 비선형 굴절률 $n_{2}$$n_{3}$를 측정하였으며, PTS 박막 도파관에서는 다중모드 출력을 관측하였다. 입력광의 세기가 2~5 GW/$cm^{2}$영역에서 PTS의 비선형 광학계수는 $n_{2}=6{\times}10^{-4}cm^{2}$/GW, $n_{3}=-7{\times}10^{-5}cm^{4}/GW^{2}$이고 2광자 흡수와 3광자 흡수는 없었다. 빛의 세기가 강한 5~16 GW/$cm^{2}$영역에서는 비선형 슈레딩거식과 빠른 푸리에변환 광전파방법을 이용하여 시료 내에서 전파광의 모양이 가우시안 광에서 왜곡되어 전파되는 것을 전산모의하였다.

  • PDF

Compressed sensing을 이용한 TOF MRA 검사에서 Flow rate와 CS factor의 변화에 따른 영향 (Effects of Flow Rates and CS Factors on TOF MRA using Compressed Sensing)

  • 김성호;정현근;유세종
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.281-291
    • /
    • 2021
  • 본 연구는 자기공명영상을 이용한 TOF MRA 검사에서 flow rate 2.0 ml 이하의 유속을 표현함에 있어 Compressed sensing의 사용에 따른 영상의 변화를 정량적으로 측정하고자 하였다. Auto-injector와 Flow phantom을 이용하여 각각의 혈류속도 구간을 설정하고 CS를 사용하지 않은 TOF without CS 기법과 CS를 이용한 TOF with CS 기법에서 CS factor의 변화에 따른 SNR, CNR, SSIM, RMSE 등을 측정하여 비교하였다. CS factor의 증가에 따라 나타나는 영상의 영향을 검증하고자 일원배치 분산분석(One-way ANOVA)을 시행하였다. 실험 결과 CS를 사용한 TOF MRA는 CS를 사용하지 않은 TOF MRA와 비교하여 SNR 및 CNR의 유의한 차이 없이 scan time이 현저하게 감소하였다. 반면 CS factor의 증가에 따라 SSIM 및 RMSE는 TOF without CS 영상과의 차이가 증가함을 나타내었다. 따라서 TOF MRA 검사 시 CS 기법을 통해 scan time을 효율적으로 감소시키되 적절한 CS factor의 범위를 충분히 고려해야 한다. 또한 CS factor와 영상의 유사도, 정밀성에 대한 지속적인 연구가 필요할 것으로 사료된다.

Electrochemical behavior of Calcium Titanate Coated Ti-6Al-4V Substrate in Artificial Saliva

  • Lee, Byoung-Cheon;Balakrishnan, A.;Ko, Myung-Won;Choi, Je-Woo;Park, Joong-Keun;Kim, Taik-Nam
    • 한국재료학회지
    • /
    • 제18권1호
    • /
    • pp.22-25
    • /
    • 2008
  • In this study, calcium titanate $(CaTiO_3)$ gel was prepared by mixing calcium nitrate and titanium isopropoxide in 2-methoxy-ethanol. $CaTiO_3$ gel was single-layer coated on Ti-6Al-4V using a sol-gel dip-coating technique. The coating was calcined at $750^{\circ}C$ in air by utilizing a very slow heating rate of $2^{\circ}C/min$. The crystalline phases of the coating were characterized by x-ray diffraction using a slow scan rate of $1^{\circ}/min$. The morphology of the coating was analyzed by scanning electron microscopy. The corrosion behavior of Ti-6Al-4V samples coated with $CaTiO_3$ films were tested in an artificial saliva solution by potentiodynamic polarization and were quantified by the Tafel extrapolation method. The electrochemical parameters showed a considerable increase in the corrosion resistance for the $CaTiO_3$-coated Ti-6Al-4V samples compared to bare substrates.

공초점현미경과 원자현미경을 이용한 초정밀 가공된 시료 표면의 영상측정 (Analysis of a micro-processed sample surface using SCM and AFM)

  • 김종배;배한성;김경호;남기중;권남익
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.577-580
    • /
    • 2005
  • Surface quality of a micro-processed sample with laser has been investigated by using of scanning confocal microscope(SCM) and atomic force microscope(AFM). Samples are bump electrodes and ITO glass of LCD module used in a mobile phone and a wafer surface scribed by UV laser. A image of $140\times120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a x-axis and y-axis are 1kHz and 1Hz, respectively. AFM is able to measure correctly hight and width of ITO and scribing depth and width of a wafer with a resolution less than 300 . However, the scan speed is slow and it is difficult to distinguish a surface composed of different nm kinds of materials. Results show that SCM is preferable to obtain a image of a sample composed of different kinds of material than AFM because the intensity of a reflected light from surface is different from each material.

  • PDF

공초점현미경과 원자현미경을 이용한 가공된 시료 표면의 형상측정 (Analysis of a processed sample surface using SCM and AFM)

  • 배한성;김경호;문성욱;남기중;권남익;김종배
    • 한국정밀공학회지
    • /
    • 제23권4호
    • /
    • pp.52-59
    • /
    • 2006
  • Surface qualities of a micro-processed sample with a pulse laser have been investigated by making use of scanning confocal microscope(SCM) and atomic force microscope(AFM). Samples are bump electrodes and ITO glass of LCD module used in a mobile phone and a wafer surface scribed by UV laser. A image of $140{\times}120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a x-axis and y-axis are 1kHz and 1Hz, respectively. AFM is able to correctly measure the hight and width of ITO, and scribing depth and width of a wafer with a resolution less than 300nm. However, the scan speed is slow and it is difficult to distinguish a surface composed of different kinds of materials. Results show that SCM is preferable to obtain a image of a sample composed of different kinds of material than AFM because the intensity of a reflected light from the surface is different for each material.

하이브리드형 AFM/SCM을 이용한 레이저 미세 가공 표면 측정 (Precision measurement of a laser micro-processing surface using a hybrid type of AFM/SCM)

  • 김종배;김경호;배한성;남기중;이대철;서운학
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.123-127
    • /
    • 2006
  • Hybrid type microscope with a Scanning Confocal Microscope (SCM) and a shear-force Atomic Force Microscope (AFM) is suggested and preliminarily studied. A image of $120{\times}120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a X-axis and Y-axis are 1kHz and 1Hz, respectively. Shear-force AFM is able to correctly measure the hight and width of sample with a resolution 8nm. However, the scan speed is slow and it is difficult to distinguish a surface composed of different kinds of materials. We have carried out the measurement of total image of a sample by SCM and an exact analysis of each image by shear-force AFM.

  • PDF

Measurement of Sub-micrometer Features Based on The Topographic Contrast Using Reflection Confocal Microscopy

  • Lee SeungWoo;Kang DongKyun;Yoo HongKi;Kim TaeJoong;Gweon Dae-Gab;Lee Suk-Won;Kim Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제9권1호
    • /
    • pp.26-31
    • /
    • 2005
  • We describe the design and the implementation of video-rate reflection confocal scanning microscopy (CSM) using an acousto-optical deflector (AOD) for the fast horizontal scan and a galvanometer mirror (GM) for the slow vertical scan. Design parameters of the optical system are determined for optimal resolution and contrast. The OSLO simulations show that the performances of CSM are not changed with deflection angle and the wavefront errors of the system are less than 0.012λ. To evaluate the performances of designed CSM, we do a series of tests, measuring lateral and axial resolution, real time image acquisition. Due to a higher axial resolution compared with conventional microscopy, CSM can detect the surface of sub-micrometer features. We detect 138㎚ line shape pattern with a video-rate (30 frm/sec). And 10㎚ axial resolution is archived. The lateral resolution of the topographic images will be further enhanced by differential confocal microscopy (DCM) method and computational algorithms.