• Title/Summary/Keyword: Slopping sites

Search Result 3, Processing Time 0.015 seconds

A Study on the Proper Definition of Ground Level under the Building Act - Difference of heights which is over 3 meters - (고저차 3m 이상 지표면의 가중평균지표면 산정방법에 관한 연구)

  • Min, Young-Gi;Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.9 no.1
    • /
    • pp.91-98
    • /
    • 2009
  • My questionaire survey revealed that even those experts that engage in architectural design did not precisely understand much of the regulations concerning ground-level. In terms of restricting the size of the building area, the generous policy of excluding balconies and basements from the calculation of building size actually causes problems. As far as the right to sunshine is concerned, the weighted average ground-level is determined to be the ground-level standard of the neighboring plot when the neighboring plot is a sloping bare ground. When the difference of heights is over 3 meters, it would be appropriate to assess the weighted ground-level standard every 3 meters.

  • PDF

A Study on the Height Limitation of a Building in Building Law - Focusing on the Standard of the Ground Level Calculation - (건축법(建築法)에서의 건축물(建築物) 높이제한규정(制限規定) - 지표면산정기준(地表面算定基準)을 중심(中心)으로 -)

  • Kim, Soo-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.29-38
    • /
    • 2003
  • The articles on building height limitation are very important to form buildings to be. The application of the articles is based on the surface of the building site ground, that is, the definite judgment of ground level should ensure the correctness of building height limitation. This study surveyed the recognition degree of practitioners about the building height limitation regulations by questionnaires, and analyzed its results and compared them to related building laws and letter of reply from the office to practitioners' inquiry on related regulation. The study summarized the results as follows; 1. It is not clear to judge the ground level. Especially in cases of pilotis structure, there would be various interpretations to define its ground level. 2. According to present building regulations, the site would be confused to define by practitioners whether it is stiff or plain. 3. In case of regulation of a right to enjoy sunshine, it is hard to calculate the average horizontal level(ground level) with neighboring sites. 4. If there were a manual with illustrations for judging and calculating the ground level of various cases, civil petitions would be reduced.

  • PDF

Development of Detachable IORT Table for Colorectal Cancer (장착-탈거 및 경사각 조절이 가능한 대장직장암의 수술 중 방사선 치료대의 개발)

  • Kim, Myung-Se;Lee, Joon-Ha
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.117-121
    • /
    • 1994
  • In spite of remarkable improvement of surgical skills and anesthesia, local failure still occurred in 36-45$ \% $ of locally advanced colorectal cancer after curative resection with or without pre-or post-operative irradiation. Intraoperative radiation therapy(IORT) is the ideal modality which resectable lesions are removed surgically 3nd the remaining cancer nests are sterilized by irradiation during a surgical procedure. Therefore, the excellent local control without the damage of the adjacent normal tissues can be achieved. In IORT, judicious set up of the treatment cone on the treatment surface of the patient is required for accurate and homogenous dose distribution within treatment field, especially on the slopping surface of sacrum and pelvic sidewall which are the common sites of the local recurrence in rectal cancer. For this purpose, adequate co-ordination of gantry rotation and table tilting are essential. Adjusting gantry rotation is not difficult but tilting of the table is impossible inconventional treatment couch. Department of Therapeutic Radiology in Yeungnam University Medical Center developed the IORT table for colorectal cancer which is easy to set up and detach on the Linac treatment couch within 5 minutes. The range of tilting with head-up and head-down is about 30 degree which is efficient and easy-to-use, not only for IORT but also for colorectal surgery. So far, authors performed IORT with newly developed treatment table in 2 patients with rectal cancer and we found that this newly developed table could contribute in improving the dose distribution of IORT and surgical procedure for colorectal cancer.

  • PDF