• Title/Summary/Keyword: Slit function

Search Result 61, Processing Time 0.023 seconds

Fourier Transformations (TEM 관련 이론해설 (2): Fourier 변환)

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.32 no.3
    • /
    • pp.195-204
    • /
    • 2002
  • In this review, the fundamental concepts of delta function, convolution integral and Fourier transformation are discussed. The applications of Fourier transformation to slit function, two very narrow slits, two slits of appreciable width, periodic array of narrow slits, arbitary periodic function, diffraction gratings and gaussian functions are also introduced.

Theoretical and Numerical Study of Cylindrical-vector-mode Radiation Characteristics in Periodic Metallic Annular Slits and Their Applications

  • Kim, Hyuntai;Jeong, Yoonchan
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.482-487
    • /
    • 2018
  • We investigate the radiation characteristics of radially polarized light and azimuthally polarized light through plasmonic subwavelength-scale annular slit (PSAS) structures, by means of both theoretical and numerical methods. Effective-medium theory was utilized to analyze the characteristics of PSAS structures, and the corresponding results showed that PSAS structures can function as a metallic medium for azimuthally polarized light, or as a low-loss dielectric medium for radially polarized light. Numerical calculations based on the finite-element method were also performed, to verify the theoretical analyses. It turned out that the numerical results supported the theoretical results. Moreover, we exploited the PSAS structures in novel nanophotonic elements with dual functionalities that could selectively focus or pass/block incident light, depending on its polarization state. For example, if PSAS structures were implemented in the dielectric region of a metallic Fresnel zone plate, the modified zone plate could function as a blocking element to azimuthally polarized light, yet as a focusing element to radially polarized light. On the contrary, if PSAS structures were implemented in the metallic region of a metallic Fresnel zone plate (i.e. the inverted form of the former), it could function as a focusing element to azimuthally polarized light, yet as a simple transparent element to radially polarized light.

Detection of Moving Position of AGV Using Rotating LSB(Laser Slit Beam) (회전 레이져 슬릿 빔을 이용한 AGV 이동위치 검출)

  • Kim, Seon-Ho;Park, Gyeong-Taek;Park, Geon-Guk;An, Jung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.137-144
    • /
    • 2001
  • The major movement blocks of the container are the range between the apron and the designation points on yard in container terminals. The yard tractor drived by operator takes charge of it's movement in conventional container terminals. In automated container terminal, AGV(automatic guided vehicle) takes charge of a yard tractor's role and information of navigation path are ordered from upper control system. The automated container terminal facilities must have the docking system that guides landing zinc to execute high speed travelling and precision positioning. This paper describes the new docking method with the rotating LSB(laser slit beam) generator and two pair of photo receiver. The LSB generator is installed on the fixed ground and the photo receiver is implemented on the moving vehicle such as AGV. The proposed docking system is implemented to confirm it's function and accuracy. The accuracy of measured moving position is represented in ±5mm at 1 data sampling.

  • PDF

Design Method of Steel Slit Shear Walls with Tapered Links for Structural Condition Assessment

  • He, Liusheng;Wu, Chen;Jiang, Huanjun
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.361-368
    • /
    • 2020
  • The authors developed a new type of steel slit shear wall (SSSW) having the function of structural condition assessment through visually inspecting the out-of-plane deformation of the designed tapered links subjected to lateral deformation. To facilitate its practical application, this paper studies how to design dimensions of the tapered links. Two parameters, the width-to-thickness ratio of the tapered links and steel yield stress, were studied. The performance of structural condition assessment was affected by both parameters with the width-to-thickness ratio being the controlling one. Through both numerical and experimental study, the designed width-to-thickness ratio of tapered links for different levels of structural condition assessment was established considering the effect of different steel grades used. In practice, the dimensions of tapered links can be determined following the design equation provided. Finally, a design procedure for the proposed SSSW system is provided.

Hemorheology and clinical application : association of impairment of red blood cell deformability with diabetic nephropathy

  • Shin, Se-Hyun;Ku, Yun-Hee
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.3
    • /
    • pp.117-123
    • /
    • 2005
  • Background: Reduced deformability of red blood cells (RBCs) may play an important role on the pathogenesis of chronic vascular complications of diabetes mellitus. However, available techniques for measuring RBC deformability often require washing process after each measurement, which is not optimal for day­to-day clinical use at point of care. The objectives of the present study are to develop a device and to delineate the correlation of impaired RBC deformability with diabetic nephropathy. Methods: We developed a disposable ektacytometry to measure RBC deformability, which adopted a laser diffraction technique and slit rheometry. The essential features of this design are its simplicity (ease of operation and no moving parts) and a disposable element which is in contact with the blood sample. We studied adult diabetic patients divided into three groups according to diabetic complications. Group I comprised 57 diabetic patients with normal renal function. Group II comprised 26 diabetic patients with chronic renal failure (CRF). Group III consisted of 30 diabetic subjects with end-stage renal disease (ESRD) on hemo-dialysis. According to the renal function for the diabetic groups, matched non-diabetic groups were served as control. Results: We found substantially impaired red blood cell deformability in those with normal renal function (group I) compared to non-diabetic control (P = 0.0005). As renal function decreases, an increased impairment in RBC deformability was found. Diabetic patients with chronic renal failure (group II) when compared to non-diabetic controls (CRF) had an apparently greater impairment in RBC deformability (P = 0.07). The non-diabetic cohort (CRF), on the other hand, manifested significant impairment in red blood cell deformability compared to healthy: control (P = 0.0001). Conclusions: The newly developed slit ektacytometer can measure the RBC deformability with ease and accuracy. In addition, progressive impairment in cell deformability is associated with renal function loss in all patients regardless of the presence or absence of diabetes. In diabetic patients, early impairment in RBC deformability appears in patients with normal renal function.

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF

슬릿 코터 노즐의 최적 설계 및 고속도포 공정의 적용 가능성에 대한 연구

  • Kim, Tae-Min;Kim, Gwang-Seon;Kim, Gi-Un;Im, Tae-Hyeon;Jeong, Eun-Mi
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.169-173
    • /
    • 2007
  • Slit-coater nozzle is one of core equipments of coating process in LCD panel manufactory. As a glass substrate size become bigger, a nozzle performance and a high-speed coating process are considered important issues. To design the optimal nozzle, the characteristics of fluid inside nozzle are studied using CFD (Computational Fluid Dynamics) method. Through research on design factors, we can know the coating uniformity influenced by lip length, cavity angle and gap size. The future work for this study is to find the factors in high-speed coating process and function between factors of design.

  • PDF

A Breaching of Electromagnetic Shielding by Narrow Aperture in Metal Film

  • Park, Doo Jae;Chu, Hong;Kyoung, Jisoo;Choi, Soo Bong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.563-566
    • /
    • 2016
  • We report a theoretical research for the condition of electromagnetic shield breaching when a narrow aperture is punctured in thin metal film. To calculate electromagnetic field transmission through a narrow slit, a Rayleigh wave expansion has been applied for free standing, thin metal film. We found that the DC electric field allows perfect transmission when the length of the slit is infinite, regardless of the other geometrical factors such as slitwidth and thickness. Slitwidth dependent transmission spectra as a function of frequency shows a cutoff frequency that decreases almost linearly to the slitwidth, giving that almost successful shielding is only possible when the slitwidth is smaller than 1 micron.

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System (비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.163-171
    • /
    • 2003
  • To evaluate the performance of the digital radiography(DR) system developed in our group, the modulation transfer function(MTF) was measured and compared with that of an analog X- ray detector, film/screen system. The DR system has an amorphous selenium(a-Se) layer vacuum-evaporated on a TFT flat panel detector. The speed class 400 film/screen (Fuji) system has been being used in the clinical field as analog X-ray detectors. Both the square wave and slit method were used to evaluate their MTF. The square method was applied to both film/screen and the DR system. The slit method, however, was applied to only DR system. The full-width half maximum resolution of film/screen was 357${\mu}{\textrm}{m}$(1.4 lp/mm at 50% spatial frequency), and the resolution of DR was limited to 200${\mu}{\textrm}{m}$(2.5 lp/mm at 30%). These results indicate the measured resolution limitations approximate to the pixel pitch, 139 ${\mu}{\textrm}{m}$ of TFT. The MTF of DR is higher than that of film/screen by the factor of 1.785. It is proved that our a-Se based DR system has potential usefulness in the clinical field.