• 제목/요약/키워드: Sliding block

검색결과 128건 처리시간 0.028초

적층 강체블록의 수직축 회전을 고려한 Sliding운동 해석과 실험 (ANALYSIS OF SLIDING MOTION OF PILED MULTI-BLOCK SYSTEMS CONSIDERING HORIZONTAL ROTATION)

  • 황인섭;김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.193-199
    • /
    • 2003
  • The most cultural heritages are composed of piled multi-block systems which are vulnerable to earthquakes. The stone of low height tends to slide when the excitation such as earthquake is applied and this sliding motion has effects on the whole response of the structure. In this study, analytical method of sliding motion of the piled multi-block systems considering horizontal rotation is developed and compared with shaking table test results. It is shown that the nonlinear analysis of sliding motion of multi-block system leads to satisfactory results.

  • PDF

강체 블록의 비선형 로킹진동특성에 관한 연구 (미끄럼이 있는 경우) (A Study on Nonlinear Rocking Vibration Characteristics of Rigid Block (In the Case of Sliding Occurrence))

  • 정만용;김정호;김선규;나기대;양인영
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 2000
  • This paper deals with rocking response behavior of rigid block structure subjected to horizontal excitation. A strict consideration of impact and sliding between the block and base is essential to investigate the rocking vibration characteristics because the rocking behavior were greatly influenced by the impact and sliding motion. Therefore, not only restitution coefficient between the block and base but also the energy dissipation rate which is associated with sliding motion, and the static and kinetic friction coefficient between those should be included in the modeling of rocking system. The analytic program was developed to be able to simulate the experimental responses of the block subjected to horizontal sinusoidal excitations. By using this program, rocking responses were numerically calculated by the nonlinear equations for rocking system. From the response simulation and rocking vibration experiment, the following results were obtained. The rocking responses are affected by the impact motion due to energy dissipation and friction and provide very complex behavior. The toppling condition of the block is also influenced by the impact motion and sliding motion.

  • PDF

지진동을 받는 중력식 안벽에 작용하는 하중산정 및 Newmark 변위해석 (Evaluation of Force Components and Newmark Sliding Block Analysis of Quay Walls during Earthquake)

  • 김성렬;하익수;권오순;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.93-100
    • /
    • 2002
  • In this paper, new simple model is developed to evaluate the variation of the magnitude and the phase contrast of force components with the development of excess pore pressure in backfill soil. Also, Newmark sliding block analysis is performed inputting the calculated total force from new model. The applicability of new simple model and Newmark sliding block model is verified from the analyses of 1g shaking table test results.

  • PDF

Chaotic Rocking Vibration of a Rigid Block with Sliding Motion Under Two-Dimensional Harmonic Excitation

  • Jeong, Man-Yong;Kim, Jeong-Ho;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1040-1053
    • /
    • 2002
  • This research deals with the influence of nonlinearities associated with impact and sliding upon the rocking behavior of a rigid block, which is subjected to two-dimensional horizontal and vertical excitation. Nonlinearities in the vibration were found to depend strongly on the effect of the impact between the block and the base, which involves an abrupt reduction in the system's kinetic energy. In particular, when sliding occurs, the rocking behavior is substantially changed. Response analysis using a non-dimensional rocking equation was carried out for a variety of excitation levels and excitation frequencies. The chaos responses were observed over a wide response region, particularly, in the cases of high vertical displacement and violent sliding motion, and the chaos characteristics appear in the time histories, Poincare maps, power spectra and Lyapunov exponents of the rocking responses. The complex behavior of chaotic response, in phase space, is illustrated by the Poincare map. The distribution of the rocking response is described by bifurcation diagrams and the effects of sliding motion are examined through the several rocking response examples.

미끄럼운동을 동반하는 강체 블록 구조물의 로킹진동 - 수평방향과 수직방향의 여진진동수가 다른 경우에 대하여 - (Rocking Vibration of Rigid Block Structure Accompaning Sliding Motion - In the Case of Two Dimensional Harmonic Excitation with Different Frequencies -)

  • 정만용;김정호;양인영
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.879-889
    • /
    • 2003
  • This research deals with the nonlinearities of rocking vibration associated with impact and sliding on the rocking behavior of rigid block under two dimensional sinusoidal excitation which has different frequencies in two excitation direction. The varied excitation direction influences not only the rocking response but also the sliding motion and the rocking response shape. Chaotic responses are observed in wider excitation amplitude region, when the frequencies in each excitation direction are different. The complex behavior of chaotic response, in the phase space, is related with the trajectory of base excitation and sliding motion.

개폐식 대공간 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구 (Watertightness Property Evaluation of Rain-Block System)

  • 김윤호;백기열;김종수;이선규;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.13-16
    • /
    • 2010
  • This study is an Investigation on the Watertightness Properties of Rain-Block System on the Sliding-Roof Joint of Large-Span Membrane Structures. In this experimental, we test the watertightness performance of joint part of sliding door in roof of large span membrane structure(for pilot project) under environment of rain and wind. A shape of rain water blocking systems of joint part in sliding door verifies the defects and effects of water leakage prevention in precipitation with the wind conditions. For obtaining watertightness of large span membrane structures, it is necessary quality of joints and performance, and quality of membrane material of a retractable roof as well as a closed roof. Also, for obtaining quality in joints, it is essential to make a watertightness guideline for design of large-span membrane.

  • PDF

기존 방조제의 내진성능평가 방법 검증 (Verification of the Seismic Performance Evaluation Methods for Enclosure Dam)

  • 김광준;김현국;김성렬;이진선
    • 한국지반공학회논문집
    • /
    • 제38권5호
    • /
    • pp.19-33
    • /
    • 2022
  • 지진시 성토사면의 잔류변위 예측에 가장 많이 사용되는 방법은 Newmark변위법이다. Newmark변위법은 지진시 강체원호의 관성력에 의한 미끌어짐량을 산정하는 방법으로 한계상태평형이론에 근거하여 산정된다. 따라서, 원호의 미끌어짐이 발생하지 않는 항복가속도 이하의 지진이 발생하는 경우 잔류변위가 발생하지 않는다고 가정한다. Newmark 변위법은 최초 제안 이후 지진응답해석기법의 결과를 도입하는 방향으로 개선되었다. 본 논문에서는 방조제 예제 단면에 대해서 Newmark변위법의 적용방법과 비선형응답이력 해석을 통한 내진성능평가 결과의 차이를 살펴보았다. 검토 결과, 설계안전율이 큰 방조제 제체에서는 Newmark변위법에 의한 잔류변위는 거의 발생하지 않았다. 반면, 비선형 응답이력해석의 결과는 비교적 유의미한 잔류변위를 나타냄을 알 수 있었다.

Roof Truss Sliding 공법 적용사례 연구 인천국제공항 교통센터 - Great Hall (A Study on the application of Roof Truss Sliding Method in the Incheon International Amort Transportation Center - Great Hall)

  • 이동렬
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2001년도 학술대회지
    • /
    • pp.214-221
    • /
    • 2001
  • 인천국제공항 교통센터의 Great Hall은 3차원의 입체적 곡면 Truss로 구성되어 있고, Great Hall Roof Truss는 최대 경간162m, 480Ton인 Truss을 포함한 13개의 Main Steel Truss로 구성되어 있다. Great Hall Roof Truss는 총 중량 6,300Ton, 9,600 Pieces로 1개의 절점당 최대 13개의 다른 부재가 접합하게 되어 있고, 12개의 Fabric 기초에 의해 지지된다. 경제적인 효과와 공기적 측면을 고려하여 기존 재래식(가설 Bent) 공법보다 Block화 공법 및 Sliding공법을 채택하였다. Roof 구조물은 3,550Ton과 2,700Ton 중량인 두 Block으로 나누고 구조물 외부에 설치 된 Giant Sleigh에 선 조립 후 Tandem Pulling Jack과 Strand를 이용하여 181m를 Sliding하여 본 구조물의 위치에 설치되었다.

  • PDF

개폐식 대공간 막 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구 (A Study on the Evaluation of Watertightness Properties for Rain-Block System in the Sliding-Roof Joint of Large-Span Membrane Structures)

  • 오상근;백기열;이선규
    • 한국건축시공학회지
    • /
    • 제10권3호
    • /
    • pp.129-136
    • /
    • 2010
  • 지붕 개폐형태의 대공간 막 구조물은 멀티미디어적인 요소 및 전천후 공간을 활용할 수 있지만, 다수의 연결 조인트에 의해 구조물이 형성되므로 누수에 취약한 문제점이 있다. 특히 개폐식 지붕 맞댐부위의 우수차단 시스템은 우수의 직접적인 유입을 차단하는 역할을 하고 있으므로 바람을 동반한 강우환경에서도 수밀성능이 요구된다. 따라서 상기의 환경 조건을 부여한 수밀성 실험을 통하여 우수차단 시스템의 디테일에 대한 수밀성능을 평가하고자 한다. 실험 결과, 모든 실험체에서 누수가 발생하였으며, 우수의 유입경로는 동일한 것으로 확인되었다. 특히, 바람에 의하여 물입자들이 구조물 내부로 들이치는 현상이 주원인이므로 이를 보완한 새로운 우수차단 시스템의 디테일이 요구된다. 이 연구를 통해 강우 환경과 바람 환경을 동시에 부여하였을 때 발생될 수 있는 우수 침입 경로를 확인하였으며, 수밀 성능 확보 유무가 사전에 검토되어 져야함을 알 수 있었다. 또한, 디테일을 사전에 작성하여 모형 수밀성 시험을 반드시 시행한 후 그 결과에 따라 설계 디테일의 변경, 개선, 보완시공을 하여야 할 것이다.