• 제목/요약/키워드: Slice Thickness

검색결과 177건 처리시간 0.026초

격강구(隔薑灸)의 연소(燃燒) 특성(特性)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on the Characteristics of Combustion in the Indirect Moxibustion with Ginger)

  • 이건목;이건휘;문성재;황병천;국우석;장지연;김양중;장재호;윤주영
    • Journal of Acupuncture Research
    • /
    • 제21권3호
    • /
    • pp.193-214
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with ginger objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with ginger. Methods : We have selected the indirect moxibustion with ginger among many indirect moxibustions. We produced a slice of ginger to a thickness of 3, 4, 5mm and the moxa cone having a diameter of 8mm, a height of 10mm for making a comparative study of characteristics of moxa cone according to change the density. We have made a comparative study of the thermodynamic characteristics of moxibustion with ginger with or without holes. We measured combustion times and calculated temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. We found out it was not significantly influenced by the existence of the punched holes in a slice of ginger because the punched holes grow smaller immediately. 2. The duration of the preheating period became longer according to thickness of a slice of ginger and was not directly proportional to the density of moxa cone. The duration of the preheating period was extremely short when it burned a 100mg moxa cone. That was influenced by the density of moxa cone. 3. The duration of the heating period became longer according to thickness of a slice of ginger likewise the preheating period bacause the density of moxa cone had effected on the combustion characteristics. The duration of the heating period was extremely long when it burned a 100mg moxa cone. On the other hand the maximum temperature in the heating period was appeared that the combustion with a thin slice of ginger was highest and measured that the large density of moxa cone was higher. But the maximum temperature in the heating period was about $37.8^{\circ}C{\sim}44.2^{\circ}C$respectively lower in others. 4. The duration of the retaining period was some doubling shorter than that of the heating period that is concerned the shape of moxa cone. The temperature measured the close of a retaining period was $36.6^{\circ}C{\sim}41.8^{\circ}C$, that was considerably lower temperature. 5. The mean ascending temperature velocity and the mean descending temperature velocity were $0.042{\sim}0.073^{\circ}C/sec$, $-0.027{\sim}-0.064^{\circ}C/sec$ respectively. Then, the ascending temperature velocity was some faster than the ascending temperature velocity. Conclusions : The quantitative standard for obtaining the effective heating stimulation is that if the slice of ginger made a hole in it, we had to use the needle above 1.5mm diameter. The recommended size of a slice ginger is the 14mm diameter and the 2~3mm thickness. The moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^2$.

  • PDF

MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가 (The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography))

  • 류귀복;김현수;유광열;동경래;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.127-132
    • /
    • 2010
  • 본 연구의 목적은 MDCT의 iso-center에서 detector의 Z-축 범위 이외에서 발생하는 산란선을 측정하고 산란선을 경감하기 위한 기준설정에 기초 자료를 제시하고자 하는 것이다. MDCT의 발전은 환자 Z-축으로의 빔의 확대를 가져오게 되었으며 이는 산란선의 증가로 이어져 피폭선량의 증가에 기여하게 되었다. 또한 MDCT는 SDCT에 비하여 빔 두께의 차이에 따라 최고 4배까지 산란선이 증가하고 있다. MDCT에서 빔 두께 변화에 따른 산란선을 평가하기 위하여 16-slice CT 1대, 64-slice CT 2대의 장비를 이용하여 다배열검출기(MDCT)의 Z-축의 넓이에 따른 산란선을 측정하였다. 측정 장비로는 이온챔버 60 ml 2026C를 사용하였다. 측정결과 장비 별 빔 두께에 따른 산란선의 변화는 동일한 kVp에서 빔 두께가 2배 증가함에 따라 평균 1.7~1.8배의 산란선의 증가가 있었다. 또한 관전압에 따른 산란선의 변화를 평가한 결과 관전압이 80 kVp에서 120 kVp로 40 kVp 증가함에 따라 64 slice 장비에서는 평균 3.47~3.79배의 산란선 증가가 있었고 16 slice 장비에서는 평균 2.47배의 산란선 증가가 있었다. 마지막으로 iso-center로부터의 거리변화에 따른 산란선을 측정한 결과 이온챔버의 거리가 2배 증가함에 따라 2.11~2.25배의 산란선 감소가 있었다. 본 연구는 의료영상 진단 장비인 CT 장비의 Z-축 빔 두께 증가와 관전압, 거리에 따른 산란선을 평가하는데 있다. 이에 따라 뇌 CT 검사 시 갑상선, 안구 등의 차폐문제와 복부 CT 검사 시 갑상선, 생식선 등의 차폐문제가 무시할 수 없음을 알 수 있었다. 현재 슬라이스 내의 선량에 대한 연구가 주로 이루어지고 있는 시점에서 본 연구를 통하여 detector의 Z-축빔 두께 증가에 따른 Z-축 범위 이외의 산란선의 증가를 이해하고, 검사목적 부위 이외의 산란선 연구에 대한 필요성과 MDCT를 이용한 CT 검사 시 차폐의 중요성을 인식하여야 한다.

두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가 (Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.131-140
    • /
    • 2003
  • 3차원 영상의 해부학 구조에 대한 정확한 거리 측정은 중요한 역할을 하고 있으므로, 인체 두개골 팬텀을 사용하여 다검출기 CT에서의 슬라이스 두께별 획득 변수에 따른 3차원 영상의 정량적 특성에 관하여 거리 측정방법에 의한 정확도 평가를 실시하였다. 두개골 팬텀의 외부에 임상적으로 중요한 의미를 갖는 21 개의 위치를 표시하고 각 점간의 거리를 실측하였다. 실측한 데이터는 3차원 재구성 영상의 계측값과 비교평가 하기 위한 기준으로 삼았다. 다검출기 CT를 사용하여 200 mA, 120 kVp의 X-선 튜브 조건과 갠트리 회전 당 스캔(scan) 시간 1초로 단면영상을 획득하였다. 축형 모드와 나선형 모드(pitch 3:1, 6:1)에서 각각 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 슬라이스 두께로 획득하였고, 나선형 모드에서 획득된 단면영상을 다시 1.25 mm로 획득하였다. 영상분석 소프트웨어를 이용하여 3차원 영상 재구성 및 거리측정을 하고 통계분석을 실시하였다. 1.25 mm, 2.50 mm, 3.75 mm, 5.00 mm의 계측값의 정확도는 각각 48%, 33%, 23%, 14%로 나타났으며 1.25 mm로 재구성한 3차원 영상의 정확도는 각각 53%, 41%, 43%, 36%로 나타났다. 그러나, 1.25 mm로 재구성한 3차원영상들 간의 거리측정의 정확도 사이에서 통계적으로 유의할 만한 수준(P-value<0.05)의 차이는 보이지 않았다. 다검출기 CT의 영상획득 변수에 따른 3차원 재구성 영상에서의 각 점간의 거리측정 결과는 피치나 스캔 모드에서 보다 슬라이스 두께와 재구성 슬라이스 두께에 따른 영향이 더욱 크다는 것을 나타내었다.

  • PDF

영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구 (Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker)

  • 김종민;김대섭;백금문;강태영;홍동기;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 2010
  • 목 적: Fiducial marker를 이용하여 움직이는 장기인 간암의 영상유도 방사선 치료 시 fiducial marker에서 발생하는 artifact의 영향에 대하여 알아보고자 한다. 대상 및 방법: 영상 유도 시스템과 CT simulator를 사용하여 고정된 fiducial marker의 artifact 크기 측정, 움직이는 fiducial marker 궤적의 길이 측정과 2차원 정합과 3차원 정합을 각각 시행하였으며, 이때 couch의 좌표 이동 값을 분석하였다. 결 과: 고정된 3.00 mm 크기의 fiducial marker artifact 크기 측정 결과 기준 CT 슬라이스 두께 1.25, 2.50, 5.00, 10.00 mm에서 CT 4.90, 8.10, 12.90, 19.70 mm, 온 보드 영상장치 5.60, 10.60, 14.70, 29.40 mm로 측정되었고, 40.00 mm로 움직이는 fiducial marker 궤적의 길이를 측정한 결과 CT 42.00, 43.10, 46.50 mm, 온 보드 영상장치 43.40, 46.0, 49.30 mm로 측정되었다. 2차원 정합과 3차원 정합 사이에 1.00, 2.00, 8.00 mm의 좌표 이동이 발생하였다. 결 론: Fiducial marker를 이용하여 영상 유도 방사선 치료를 시행 할 때 fiducial marker에서 발생하는 artifact를 고려하여 slice thickness를 2.50 mm 이하로 설정하는 것이 치료 오차를 최소화 할 수 있는 방법이라 생각한다.

  • PDF

Quantitative Measurements of 3-D Imaging with Computed Tomography using Human Skull Phantom

  • Kim, Dong-Wook;Kim, Hee-Joung;Haijo Jung;Soonil Hong;Yoo, Young-Il;Kim, Dong-Hyeon;Kim, Kee-Deog
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.506-508
    • /
    • 2002
  • As an advancement of medical imaging modalities and analyzing software with multi-function, active researches to acquire high contrast and high resolution image being done. In recently, development of medical imaging modalities like as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) is aiming to display anatomical structure more accuracy and faster. Thus, one of the important areas in CT today is the use of CT scanner for the quantitative evaluation of 3-D reconstruction images from 2-D tomographic images. In CT system, the effective slice thickness and the quality of 3-D reconstructed image will be influenced by imaging acquisition parameters (e.g. pitch and scan mode). In diagnosis and surgical planning, the accurate distance measurements of 3-D anatomical structures play an important role and the accuracy of distance measurements will depend on the acquisition parameters such as slice thickness, pitch, and scan mode. The skull phantom was scanned with SDCT for various acquisition parameters and acquisition slice thicknesses were 3 and 5 mm, and reconstruction intervals were 1, 2, and 3 mm to each pitch. 3-D visualizations and distance measurements were performed with PC based 3-D rendering and analyzing software. Results showed that the image quality and the measurement accuracy of 3-D SDCT images are independent to the reconstruction intervals and pitches.

  • PDF

Wistar 쥐 조직을 이용한 L-Glutamine 바이오센서 (The Biosensor for L-Glutamine Using Tissue Slices of Wistar Rat)

  • 배진현;최성문;임동준;김위락
    • 대한화학회지
    • /
    • 제38권3호
    • /
    • pp.200-207
    • /
    • 1994
  • Wistar계 쥐의 신장 조직을 암모니아 기체 감응전극에 고정화하여 조직센서를 제작하고, L-glutamine을 정량하기 위한 최적 조건을 조사하였다. 그 결과, $30^{\circ}C$, pH 7.8의 0.05M 인산완충용액과 30 ${\mu}m$ 두께의 신장을 사용하였을 경우, 정량 가능한 직선범위는$ 8.0{\times}10^{-5}{\sim}1.0{\times}10^{-2} M$이었으며, 감응도는 53.8 mV/decade로 나타났고, 감응시간은 3~5분 소요되었다. 또한 같은 최적 조건하에서 조직을 파쇄하여 얻은 세포소기관을 전극에 고정화시킨 센서의 경우, 정량 가능한 직선범위는 $1.2{\times}10^{-4}{\sim}5.0{\times}10^{-3} M$이었으며, 감응도는 54.0 mV/decade, 감응시간은 6~7분이 소요되었다. 이와 같이 본 연구에서는 쥐의 신장 조직 및 세포 소기관을 이용하여 L-glutamine을 정량 분석할 수 있는 조직센서 개발에 관하여 연구하였다.

  • PDF

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Drying Ginseng Slices Using a Combination of Microwave and Far-Infrared Drying Techniques

  • Gong, Yuan Juan;Sui, Ying;Han, Chung Su;Ning, Xiao Feng
    • Journal of Biosystems Engineering
    • /
    • 제41권1호
    • /
    • pp.34-42
    • /
    • 2016
  • Purpose: This study was performed to improve the drying quality and drying rate of ginseng slices by combining microwave and far-infrared drying techniques. Methods: Based on single-factor experiments and analyses, a quadratic regression orthogonal rotation combination design was adopted to study the effects of the moisture content at the conversion point between the microwave and far-infrared techniques, the ginseng slice thickness and the far-infrared drying temperature on the chip drying time, the surface color difference value, the nutritional composition and the surface shrinkage rate index. Results: Compared to the far-infrared drying alone, the combined microwave and far-infrared drying resulted in an increase in the saponin content of the ginseng slices and reductions in the drying time, surface color difference, and shrinkage rate. Conclusions: We established a mathematical model of the relationships between the surface shrinkage rate index and the experimental factors using the multi-objective nonlinear optimization method to determine the optimal parameter combination, which was confirmed to be the following: microwave and far-infrared moisture contents of 65%, a ginseng slice thickness of 1 mm, and a far-infrared drying temperature of $54^{\circ}C$.

라멜라균열의 생성온도와 비금속개재물의 영향 (Determination of Lamellar Tearing Initiation Temperatures and the Effect of Non-metallic Inclusions on Tear)

  • 고진현
    • Journal of Welding and Joining
    • /
    • 제10권2호
    • /
    • pp.43-50
    • /
    • 1992
  • This study was aimed at resolving uncertainties about lamellar tearing initiation temperatures and studying the effect of nonmetallic inclusions on the tear initiation. In order to measure the lamellar tearing initiation temperature, the slice bend test was conducted in the temperature range of 20.deg.C to 425.deg.C on A572 Grade 50 and A588 Grade A steels. In addition, the weld restrain test was carried out to measure directly the tear initiation temperature with A572 steel. In slice bend tests, A572 steel showed the most susceptible region to lamellar tearing to be in the range of 100 to 300.deg.C, where the steel showed the minimum ductility. The observed tear initiation by the weld restraint test was to be in the range of 200to 300.deg.C. The tears became narrower and less rounded at the susceptible temperatures. It was confirmed in this study that lamellar teraring initiated during cooling from welding in the range of 200 to 300.deg.C and they were initiated by strain aging embrittlement.

  • PDF

토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교 (Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy)

  • 이병구;강수만
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.145-149
    • /
    • 2013
  • 의료용 선형가속기 (linear accelerator)와 나선형 컴퓨터 단층 촬영 장치 (helical computed tomography scanner)의 결합 장치인 토모테라피는 세기 변조 방사선 치료 (intensity modulated radiation therapy(IMRT))의 큰 혁신을 이끌었다. 토모테라피 치료 과정에서, Megavoltage computed tomography (MVCT) 영상획득은 치료 환자의 정확한 자세 정렬을 위해 치료 전 또는 후에 이용된다. 그러나 이는 환자의 총 선량을 증가시키는 결과를 만들며, 본 연구는 이처럼 MVCT 영상 획득 시 증가되는 선량을 Cylindrical "Cheese" Phantom을 이용하여 측정, 비교하였다. 각각의 pitch 별로 (1, 2, 3 mm) 동일한 개수의 slice (10 slice), 그리고 동일한 length (약 9 cm)를 scanning하여, 이때의 선량 (MVCT Scanning Dose)을 A1SL ion chamber를 이용하여 측정하였다. 측정 결과 동일한 Slice 개수 (각각의 pitch 당 10개)일 때, MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.24 cGy, 1.02 cGy, 0.81 cGy가 측정되었다. 동일한 length에서 MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.47 cGy, 1.28 cGy, 0.88 cGy가 측정되었다. 이는 할당된 pitch와 scanning length가 MVCT scanning dose에 큰 영향을 미치는 가장 중요한 매개 변수임을 말하며, pitch는 MVCT scanning dose와 역비례 관계를 나타냈다. 때문에 적절한 pitch와 scanning length의 선택으로 치료 선량 외의 추가 선량을 최소로 줄여야 하겠다.