• Title/Summary/Keyword: Slice

Search Result 983, Processing Time 0.023 seconds

RIQUIER AND DIRICHLET BOUNDARY VALUE PROBLEMS FOR SLICE DIRAC OPERATORS

  • Yuan, Hongfen
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.1
    • /
    • pp.149-163
    • /
    • 2018
  • In recent years, the study of slice Dirac operators has attracted more and more attention in the literature. In this paper, Almansitype decompositions for null solutions to the iterated slice Dirac operator and the generalized slice Dirac operator are obtained without a star-like domain centered at the origin. As applications, we investigate Riquier type problems and Dirichlet type problems in the theory of slice monogenic functions.

Effects of Antibrowning agents on browning of apple slices during cold storage (냉장저장 중 사과 슬라이스의 갈변에 미치는 갈변저해제의 효과)

  • Ahn Sun-Choung;Lee Gui-Chu
    • Korean journal of food and cookery science
    • /
    • v.21 no.1 s.85
    • /
    • pp.24-32
    • /
    • 2005
  • Changes in apple slices during cold storage were investigated by evaluating the physical properties such as degree of browning and compression force. Chemical properties such as PPO activity and total phenol contents were also determined and sensory evaluation was carried out. The correlation analysis between browning parameters was conducted. Degree of browning was increased in the order of fresh apple slice, water-dipped apple slice, $0.5\%$ ascorbic acid solution-dipped apple slice and CP(caramelization product) from sucrose-dipped apple slice. PPO activity was increased in the order of fresh apple slice, water-dipped apple slice, $0.5\%$ ascorbic acid solution-dipped apple slice and CP(caramelization product) from sucrose-dipped apple slice. Amongst several treatments, CP from sucrose-dipped apple slice showed the lowest degree of browning and PPO activity. Total phenol contents were decreased from 60 to 56.2 mg and from 59.6 to 56.0 mg in fresh apple slice and water-dipped apple slice, respectively, but CP from sucrose-dipped apple slice and $0.5\%$ ascorbic acid solution-dipped apple slice were increased from 51.9 to 52.8 mg and from 54.1 to 54.4 mg, respectively, showing the smallest changes when compared with fresh apple slice and water-dipped apple slice. Compression forces of apple slices during cold storage were decreased in the order of fresh apple slice, water-dipped apple slice, $0.5\%$ ascorbic acid solution-dipped apple slice and CP from sucrose-dipped apple slice. In sensory evaluation of apple slices during cold storage, CP from sucrose-dipped apple slice had higher score than the other treatments. In addition, a significant correlation was observed among degree of browning, PPO activity and phenol content. Therefore, CP from sucrose-dipped apple slice seems to be effective in controlling of enzymatic browning during cold storage. In addition, CP from sucrose-dipped apple slice seems to be effective on other several factors. These results suggest that CP from sucrose should be a potential source for controlling enzymatic browning during storage of vegetables and fruits.

Effect of the slice thickness and the size of region of interest on CT number (상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향)

  • Lee Ji-Youn;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

ON THE TRANSFORMATION FORMULA OF THE SLICE BERGMAN KERNELS IN THE QUATERNION VARIABLES

  • Park, Jong-Do
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.5
    • /
    • pp.1401-1409
    • /
    • 2016
  • In complex analysis, the Bergman kernels for two biholomorphically equivalent complex domains satisfy the transformation formula. Recently new Bergman theory of slice regular functions of the quaternion variables has been investigated. In this paper we construct the transformation formula of the slice Bergman kernels under slice biregular functions in the setting of the quaternion variables.

S/W model of Plastic Slice for Semi-federated Slice Control of Future Internet Testbed (미래인터넷 테스트베드의 Semi-federated Slice Control을 위한 Plastic Slice의 S/W 모델)

  • Cha, Byung-Rae;Kim, Jong-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.817-830
    • /
    • 2012
  • In rapid changes in communications and computing environment, due to the increasing variety of user requirements, and an effort to solve the fundamental problems with the current Internet, Future Internet researches actively have been performed at domestic and abroad. In this paper, we proposed the idea and basic concept of Plastic slice software mode about federation job control in study topic of future internet.

Three-Dimensional Volume Assessment Accuracy in Computed Tomography Using a Phantom (모형물을 이용한 전산화 단층 촬영에서 3차원적 부피측정의 정확성 평가)

  • Kim, Hyun-Su;Wang, Ji-Hwan;Lim, Il-Hyuk;Park, Ki-Tae;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.268-272
    • /
    • 2013
  • The purpose of this study was to assess the effects of reconstruction kernel, and slice thickness on the accuracy of spiral CT-based volume assessment over a range of object sizes typical of synthetic simulated tumor. Spiral CT scanning was performed at various reconstruction kernels (soft tissue, standard, bone), and slice thickness (1, 2, 3 mm) using a phantom made of gelatin and 10 synthetic simulated tumors of different sizes (diameter 3.0-12.0 mm). Three-dimensional volume assessments were obtained using an automated software tool. Results were compared with the reference volume by calculating the percentage error. Statistical analysis was performed using ANOVA and setting statistical significance at P < 0.05. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were larger than the actual volumes by a common factor depending on slice thickness; in 100HU simulated tumors that had statistically significant, 1 mm slice thickness produced on average 27.41%, 2 mm slice thickness produced 45.61%, 3 mm slice thickness produced 93.36% overestimates of volume. However, there was no statistically significant difference in volume error for spiral CT scans taken with techniques where only reconstruction kernel was changed. These results supported that synthetic simulated tumor size, slice thickness were significant parameters in determining volume measurement errors. For an accurate volumetric measurement of an object, it is critical to select an appropriate slice thickness and to consider the size of an object.

An Efficient Network Slice Configuration Method in 5G Mobile Networks

  • Kim, Jae-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.9
    • /
    • pp.101-112
    • /
    • 2022
  • In this paper, we analyze 5G network slicing and propose an efficient network slice configuration method in 5G mobile networks. Network slicing can be identified and performed based on the network slice instance information in 5G mobile networks. In case of discordance between the UE's network slice instance information and the network's one, the unnecessary signalling overhead occurs, when the UE's PDU Session Establishment request to the network fails. To solve this problem, this paper proposes two efficient network slice configuration methods, the UE-based ENSC(Efficient Network Slice Configuration) method and the Network-based ENSC method. The proposed schemes perform the prompt the configuration and provision of the updated network slice instance information between the UE and network and improve battery and resource efficiency and minimize unnecessary signalling overhead compared to existing methods in 5G mobile networks.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

The Use of VFG for Measuring the Slice Complexity (슬라이스 복잡도 측정을 위한 VFG의 사용)

  • 문유미;최완규;이성주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.183-191
    • /
    • 2001
  • We develop the new data s]ice representation, called the data value flow graph(VFG), for modeling the information flow oil data slices. Then we define a slice complexity measure by using the existing flow complexity measure in order to measure the complexity of the information flow on VFG. We show relation of the slice complexity on a slice with the slice complexity on a procedure. We also demonstrate the measurement scale factors through a set of atomic modifications and a concatenation operator on VFG.

  • PDF

Performance Comparison of S-MMA Adaptive Equalization Algorithm by Slice Weighting Value in 16-QAM Signal (16-QAM 신호에서 Slice 가중치에 의한 S-MMA 적응 등화 알고리즘의 성능 비교)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.55-61
    • /
    • 2013
  • This paper compare the performance of S-MMA(Sliced-MultiModulus Algorithm) adaptive equalization algorithm by effect of slice weighting value for the minimization of the distortion and noise in the communication channel.. In the traditional MMA algorithm, the output signal of equalizer and the dispersion constant of transmitting signal is used for calculating the equalizer coefficient, but in S-MMA, the output of equalizer and dispersion constant and the considering the output of decision device by the power of slice constant are used in order to simultaneously compensate the distortion of amplitude and phase distortion. It is confirmed by computer simulation that the slice weighting value affects the performance of adaptive equalization algorithm. The performance index includes the output signal constellation, the residual isi and maximum distortion and MSE that is for the convergence characteristics, the SER according to the signal and noise power ratio at the channel is used. As a result of simulation, the residual isi, maximum distortion and MSE performances are better in the small weighting values. But in SER performance is better in the large weighting values.