• Title/Summary/Keyword: Slew-rate Ratio

Search Result 4, Processing Time 0.017 seconds

A Study on In-Process Performance Diagnosis of Hydraulic Servovalves - First Report : Position Control System - (유압서보밸브의 인-프로세스 성능 진단에 관한 연구 I - 유압실린더 위치제어계의 경우 -)

  • Kim S.D.;Kim K.H.;Song J.S.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an in-process diagnosis method for performance of position control servo system was studied, which was based upon null bias, slew-rate ratio and delay time measurement. Slew-rate ratio and delay time were analyzed by theoretical analysis, computer simulation and experiment. As a result of these analysis, when spool of servovalve was weared, slew-rate ratio was decreased and delay time was increased.

  • PDF

Suppression Control of the Drivetrain-Oscillations of an Electric Vehicle Using Taguchi Method (다구찌 방법을 이용한 전기자동차 구동계의 진동 억제 제어)

  • Kim, Ho-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.463-468
    • /
    • 2009
  • Torsional oscillations of the drivetrain in electric vehicles are generated under rapid driving conditions. These lead to an uncomfortable jerking of the vehicle and an increased stress of the mechanical components. To suppress torsional oscillations, the low pass and notch filters between the torque command from the acceleration pedal and electric motor input torque are suggested. The filter parameters are optimized based on Taguchi method with $L_{18}(3^5)$ orthogonal array. The signal to noise (S/N) ratio mainly depends on slew rate of motor input torque, damping ratio and natural frequency of notch filter. With the proposed suppression control scheme, the S/N ratio is shown to be increased by 4.7dB and the torque overshoot of the drive shaft is reduced to 30%.

Magnetoresistive Effect in Ferromagnetic Thin Films( II) (강자성체 박막(Co-Ni)의 자기-저항효과에 관한 연구(II))

  • Chang, C.J.;Yoo, J.Y.;Nam, S.W.;Son, D.R.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.68-77
    • /
    • 1994
  • Grid type 70Ni-30Co thin films on slide glass at $250^{\circ}C$ has been fabricated to develope. From fabricated sensors using above process, we investigated the relation of temperature, resistivity, line width to magnetoresistance and we obtained the following results after observation of coercive force, saturated magnetization, maxium usable sensitivity, delay time, slew rate, white noise, resolution of the sensors. We confirmed that the $600{\AA}$ thin film at $250^{\circ}C$ formed crystalized magnetic anisotropy spontaneously and the sensor using the thin film had capability of detecting magnetic field with sensitivity of 230 nT. In these devices, the magnetoresistance change was increased linearly in ${\pm}10$ Oe range, and the magnetoresistance effect was increased when the ratio between line width and length was increased. When the devices was soldered using indium, the temperature-resistivity coefficient showed $8{\times}10^{-3}/deg$ and increased during the specific properties as magnetic field sensor were weakened. In this studies, the coercive forces of the films were about 5.1 A/cm and saturated magnetizations were 0.64 T, and the delay time in these devises was $5{\mu}s$ and slew rate showed 0.39 $Oe/{\mu}s$ and white noise was -120 dB.

  • PDF

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF