• Title/Summary/Keyword: Sleep-wake state

Search Result 19, Processing Time 0.03 seconds

The Effect of Mandibular Protrusion on Dynamic Changes in Oropharyngeal Caliber (하악의 전방이동이 구인두 내경의 동적 변화에 미치는 영향)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.193-202
    • /
    • 2010
  • The purpose of this study was to determine the sites of narrowing/obstruction and to measure the regional severity of narrowing through the evaluation of dynamic changes in upper-airway of healthy subjects. The selected 9 subjects were proved not to have any sleep-related disorder such as snoring or obstructive sleep apnea through clinical examination, radiological examination, sleep study with a portable recording system. Afterward, the Electron Beam Tomography was performed during the waking and sleeping state of subjects, with their mandible in resting and protruded position. Intravenous injection of Dormicum$^{(R)}$ was used for the induction of sleep. The maximum and minimum cross-sectional areas at each airway level during tidal ventilation were measured and the Collapsibility Index for each level of cross-section was also computed. In a comparison with results under variable conditions, the result was showed that the significant difference between each airway level divided with upper, middle, lower region of upper airway is not observed in the average minimum cross-sectional areas and Collapsibility Index. The significant difference only between in wake and sleep state was observed in the average minimum cross-sectional area at the lower region. Also, in wake state, the significant difference between resting and protrusive position of mandible for the average minimum was also observed in cross-sectional area at middle region. In sleep state, no significant difference between resting and protrusive position of mandible was observed in cross-sectional area and the Collapsibility Index.

Analysis of Sleep Questionnaires of Patients who Performed Overnight Polysomnography at the University Hospital (한 대학병원에서 철야 수면다원검사를 시행한 환자들의 수면설문조사 결과 분석)

  • Kang, Ji Ho;Lee, Sang Haak;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyoung;Song, Jeong Sup;Park, Sung Hak;Moon, Hwa Sik;Park, Yong Moon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.1
    • /
    • pp.76-82
    • /
    • 2006
  • Background : The objective of this study was to understand sleep-related problems, and to determine whether the sleep questionnaires is a clinically useful method in patients who need polysomnography. Methods : Subjects were patients who performed polysomnography and who asked to answer a sleep questionnaires at the Sleep Disorders Clinic of St. Paul's Hospital, Catholic University of Korea. Baseline characteristics, past medical illness, behaviors during sleep-wake cycle, snoring, sleep-disordered breathing and symptoms of daytime sleepiness were analyzed to compare with data of polysomnography. Results : The study population included 1081 patients(849 men, 232 female), and their mean age was $44.2{\pm}12.8years$. Among these patients, 38.9% had an apnea-hypopnea index(AHI)<5, 27.9% had $5{\leq}AHI<20$, 13.2% had $20{\leq}AHI<40$, and 20.0% had $40{\leq}AHI$. The main problems for visiting our clinic were snoring(91.7%), sleep apnea(74.5%), excessive daytime sleepiness(8.0%), insomnia(4.3%), bruxism(1.1%) and attention deficit(0.5%). The mean value of frequency of interruptions of sleep was 1.6 and the most common reason was urination(46.3%). Epworth Sleepiness Scale(ESS) had a weak correlation with AHI(r=0.209, p<0.01). When we performed analysis of sleep questionnaires, there were significant differences in the mean values of AHI according to the severity of symptoms including snoring, daytime sleepiness, taking a nap and arousal state after wake(p<0.05). Conclusion : On the basis of statistical analysis of sleep questionnaires, the severity of subjective symptoms such as ESS, snoring, daytime sleepiness and arousal state after wake correlated with the AHI significantly. Therefore the sleep questionnaires can be useful instruments for prediction of the severity of sleep disorder, especially sleep-disordered breathing.

Smartphone-based Wavelength Control LED Lighting System according to the Sleep-Wake Cycle of Occupants (재실자의 수면-각성 주기에 따른 스마트폰 기반 파장제어 LED 조명시스템)

  • Kim, Yang-Soo;Kwon, Sook-Youn;Hwang, Jun;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Melatonin hormone involved in human's circadian rhythm adjustment sensitively responds to light's specific short wavelength ratio. A shift worker's circadian rhythm disturbance and sleep disorder are caused by the existing lighting conditions, whose short wavelength ratio is fixed. The life pattern of a shift worker changes irregularly because of irregular working hours and the same lighting environment; thus, his/her concentration is reduced. For such a reason, negative effects ensue to the detriment of healthy everyday life, including a high risk of accidents or having unsound sleep after leaving work. A smartphone-based wavelength control LED lighting system that targets shift workers and that can easily measure and control lighting suitable for wake-sleep cycle, according to working hours and closing hours, is proposed in this paper. First, after the light characteristics of LED lighting that changes depending on light control ratio are measured through the color sensor installed on the smartphone and the externally-linked Mini-Spectrometer, they are stored in the database. Based on the stored optical characteristics data, the measurement module and light control module are implemented. Lighting is offered using a control ratio having the maximum rate of short wavelength in consideration of the target illuminance, classified according to work type by identifying working hours as time when waking is required for shift workers. After a shift work leaves work, the amount of lighting is varied, using a control ratio having a minimum short wavelength rate so that a shift worker can enter the sleep state naturally.

Sleep/Wake Dynamic Classifier based on Wearable Accelerometer Device Measurement (웨어러블 가속도 기기 측정에 의한 수면/비수면 동적 분류)

  • Park, Jaihyun;Kim, Daehun;Ku, Bonhwa;Ko, Hanseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.126-134
    • /
    • 2015
  • A sleep disorder is being recognized as one of the major health issues related to high levels of stress. At the same time, interests about quality of sleep are rapidly increasing. However, diagnosing sleep disorder is not a simple task because patients should undergo polysomnography test, which requires a long time and high cost. To solve this problem, an accelerometer embedded wrist-worn device is being considered as a simple and low cost solution. However, conventional methods determine a state of user to "sleep" or "wake" according to whether values of individual section's accelerometer data exceed a certain threshold or not. As a result, a high miss-classification rate is observed due to user's intermittent movements while sleeping and tiny movements while awake. In this paper, we propose a novel method that resolves the above problems by employing a dynamic classifier which evaluates a similarity between the neighboring data scores obtained from SVM classifier. A performance of the proposed method is evaluated using 50 data sets and its superiority is verified by achieving 88.9% accuracy, 88.9% sensitivity, and 88.5% specificity.

A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change- (감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로-)

  • 이자형;하영수
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF

A Case of Childhood Obstructive Sleep Apnea Syndrome with Co-morbid Attention Deficit Hyperactivity Disorder Treated with Continuous Positive Airway Pressure Treatment (지속적(持續的) 상기도(上氣道) 양압술(陽壓術)을 시행(施行)하여 치료효과(治療效果)를 본 주의력(注意力) 결핍(缺乏).과잉(過剩) 운동장애(運動障碍)를 동반(同伴)한 소아기(小兒基) 폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症) 1례(例))

  • Sohn, Chang-Ho;Shin, Min-Sup;Hong, Kang-E;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Obstructive sleep apnea syndrome(OSAS) in childhood is unique and different n-om that in adulthood in several aspects, including pathophysiology, clinical features, diagnostic criteria, complications, management, and prognosis. Characteristic features of childhood OSAS in comparison with the adult form are the variety of severe complications such as developmental delay, more prominent behavioral and cognitive impairments, vivid cardiovascular symptoms, and increased death risk, warranting a special attention to the possible diagnosis of OSAS in children who snore. However, the childhood OSAS is often neglected and unrecognized. We, therefore, report a case of very severe OSAS in a 5-year-old boy who was sucessfully treated with continuous positive airway pressure(CPAP) treatment. Interestingly, the patient was comor-bid with the attention deficit hyperactivity disorder. Prior to the initial visit to us, adenotonsillectomy had been done at the age of 4 with no significant improvement of apneic symptoms and heavy snoring. On the initial diagnostic procedures, marked degree of snoring was audible even in the daytime wake state and the patient was observed to be very hyperactive. Increased pulmonary vascularity with borderline cardiomegaly was noted on chest X-ray. The baseline polysomnography revealed that the patient was very sleep-apneic and snored very heavily, with the respiratory disturbance index(RDI) of 46.9 per hour of sleep, the mean SaO2 of 78.8%, and the lowest SaO2 of 40.0%(the lowest detectable oxygen level by the applied oxymeter). The second night polysomnography was done for CPAP titration and the optimal pressure turned out to be $8.0\;cmH_2O$. The applied CPAP treatment was well tolerated by the patient and was found to be very effective in alleviating heavy snoring and severe repetitive sleep apneas. After 18 months of the CPAP treatment, the patient was followed up with nocturnal polysomnography(baseline and CPAP nights) and clinical examination. Sleep apneas were still present without CPAP on the baseline night. However, the severity of OSAS was significantly decreased(RDI of 15.7, mean SaO2 of 96.2%, and the lowest SaO2 of 83.0%), compared to the initial polysomnographic findings before initiation of long-term CPAP treatment. Wechsler intelligence tests done before and after the CPAP treatment were compared with each other and surprising improvement of intelligence(total 9 points, performance 16 points) was noted. Clinically he was found to be markedly improved in his attention deficit hyperactive behavior after CPAP treatment, but with minimal change of TOVA(test of variables of attention) scores except conversion of reaction time score into normal range. On the chest X-ray taken after 18 months of CPAP application, the initial cardiopulmonary abnormalities were not found at all. We found that the CPAP treatment in a young child is very effective, safe, and well-tolerated and also improves the co-morbid attention deficit hyperactive symptoms. Overall, the growth and development of the child has been facilitated with the long-term use of CPAP. Cardiovascular complications induced by OSAS have been also normalized with CPAP treatment. We suggest that early diagnosis and active treatment intervention of OSAS in children are crucial in preventing and ameliorating possible serious complications caused by repetitive sleep apneas and consequent hypoxic damage during sleep.

  • PDF

Optimized Design of Low-power Adiabatic Dynamic CMOS Logic Digital 3-bit PWM for SSL Dimming System

  • Cho, Seung-Il;Mizunuma, Mitsuru;Yokoyama, Michio
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.4
    • /
    • pp.248-254
    • /
    • 2013
  • The size and power consumption of digital circuits including the dimming circuit part will increase for high-performance solid state lighting (SSL) systems in the future. This study examined the low-power consumption of adiabatic dynamic CMOS logic (ADCL) due to the principles of adiabatic charging. Furthermore, the designed low-power ADCL digital pulse width modulation (PWM) was optimized for SSL dimming systems. For this purpose, an ADCL digital 3-bit PWM was optimized in two steps. In the first step, the architecture of the ADCL digital 3-bit PWM was miniaturized. In the second step, the clock cut-off circuit was designed and added to the ADCL PWM. As a result, compared to the original configuration, 60 transistors and 15 capacitors of ADCL digital 3-bit PWM were reduced for miniaturization. Moreover, the clock cut-off circuit, which controls wake-up and sleep mode of ADCL D-FFs, was designed. The power consumption of an optimized ADCL digital PWM for all bit patterns decreased by 54 %.

  • PDF

Drowsiness Driving Prevention System using Bone Conduction Device

  • Hahm, SangWoo;Park, Hyungwoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4518-4540
    • /
    • 2019
  • With the development of IT convergence technology, autonomous driving has gradually developed; however, the vehicle is still operated by the driver, who should always be in good health - but sometimes, this is not the case. It is especially dangerous to drive when drowsy, and unable to fully concentrate on driving, such as when taking certain medicines, or through fatigue. Drowsy driving is at least eight times more dangerous than normal driving, and as dangerous as drunk driving. Previous research has looked at technology to detect drowsiness, in order to wake up drivers when necessary, or to safely stop the vehicle. Furthermore, many studies have been conducted to find out when drowsiness occurs. However, it is more desirable for the driver to take sufficient rest during a break, in order to be able to continue to focus and drive. In other words, it is important to maintain a normal state before drowsiness. In this study, we introduce a sound source to increase driver concentration and prevent drowsiness, another that can improve the quality of sleep, and a system that produces these sound sources. The proposed system has a noise reduction effect of about 15 dB. We have confirmed that the proposed sound induces an EEG of the desired form.

An Energy-Efficient Asynchronous Sensor MAC Protocol Design for Wireless Sensor Networks (무선 센서 네트워크를 위한 에너지 효율적인 비동기 방식의 센서 MAC 프로토콜 설계)

  • Park, In-Hye;Lee, Hyung-Keun;Kang, Seok-Joong
    • Journal of IKEEE
    • /
    • v.16 no.2
    • /
    • pp.86-94
    • /
    • 2012
  • Synchronization MAC Protocol such as S-MAC and T-MAC utilize duty cycling technique which peroidically operate wake-up and sleep state for reducing energy consumption. But synchronization MAC showed low energy efficiency because of additional control packets. For better energy consumption, Asychronization MAC protocols are suggested. For example, B-MAC, and X-MAC protocol adopt Low Power Listening (LPL) technique with CSMA algorithm. All nodes in these protocols joining a network with independent duty cycle schedules without additional synchronization control packets. For this reason, asynchronous MAC protocol improve energy efficiency. In this study, a low-power MAC protocol which is based on X-MAC protocol for wireless sensor network is proposed for better energy efficiency. For this protocol, we suggest preamble numbering, and virtual-synchronization technique between sender and receive node. Using TelosB mote for evaluate energy efficiency.