• 제목/요약/키워드: Slave module

검색결과 61건 처리시간 0.027초

모듈형 3상 무정전 전원장치의 병렬 운전을 위한 주종 제어 알고리즘 (A Master and Slave Control Algorithm for Parallel Operation of Modular 3-Phase UPS System)

  • 이태영;조영훈;임승범;안창헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.479-480
    • /
    • 2016
  • This paper introduces a master and slave control algorithm for parallel operation of UPS system. If each module of UPS system control the output voltage and filter inductor current in parallel operation, it occur unbalanced output power each module. To operate UPS system parallel, it need a algorithm that control output power of modules. A master and slave control algorithm is helpful to balance output power of modules by controlling output current. The effect of a master and slave control algorithm is proved by simulations.

  • PDF

Master-Slave 방식을 적용한 가정용 PV Charging Module 개발에 관한 연구 (A Study on Development of PV Charging Module for Home Using Master-Slave Method)

  • 정도영;차인수;정경환;김성민;김락준;강병복
    • 에너지공학
    • /
    • 제29권1호
    • /
    • pp.44-51
    • /
    • 2020
  • ESS의 중요성은 네트워크 신뢰성 저하 및 재생 가능 에너지원의 확장으로 인한 전력 수요의 안정화로 인해 강조되었다. ESS (Energy Storage System)는 남은 전력을 저장하고 전력 수요를 충족시키기 위해 필요할 때 이를 사용하며 주로 태양 광 및 풍력과 연계하여 ESS 시스템을 구축한다. 본 논문에서는 낮은 일사량에 효과적인 Master-Slave 방법을 이용한 가정용 PV 충전 모듈을 제안한다. 모듈을 설계 한 후 고속 MPPT 알고리즘이 적용되어 PV 모듈의 비선형 출력 특성에서 최대 출력을 생성한다. PV 충전 모듈의 입력에 대한 평균 전력 값은 296.90 W, 출력 전력은 289.60 W로 평균 97.54 %의 전력변환 효율을 보인다.

자기유지 시스템용 효율적인 에너지 사용을 위한 에너지 전력 관리 시스템 연구 (A Study on the Energy-Power Management System for Self-Sustaining Sensor Node System)

  • 황지훈;김종홍;김현웅;노형환;오하령;성영락;박준석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.349-352
    • /
    • 2009
  • WBAN/USN systems are applied from the various environment. Therefore, it is coming to be important efficient use power and communication method. The present paper materialize Slave node system which get power from light energy. Also, it materialize Wake-up module and self-power-off circuit which use S-R Flip Flop for efficient using power. This system can be efficient using power at Slave node system. Also, it can be possible application of Self sustaining system by performance verification Wake-up module which determine system "on" without power and Self-power-off circuit.

  • PDF

Mastey-Slave 개념을 이용한 PLC용 다대다 통신 모듈 개발 (A multiple PLC wireless communication module using master-slave control concept)

  • 박종석;현웅근;김이곤
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.48-48
    • /
    • 2000
  • We developed a wireless communication system for multiple instrumentation system. The developed system has a function of remote instrumentation and PLC(Programmable Logic Controller) control. The system consists of CC(Control and Communication) protocol, wireless media access and physical media system. For multiple wireless communication, we propose a hub polling protocol based on master-slave control concept. To show the validity of the developed system, several experiments are illustrated.

  • PDF

FX3 USB 3 브릿지 칩과 slave FIFO 인터페이스를 사용하는 FPGA 검증 시스템 구현 (Implementation of FPGA Verification System with Slave FIFO Interface and FX3 USB 3 Bridge Chip)

  • 최병윤
    • 한국정보통신학회논문지
    • /
    • 제25권2호
    • /
    • pp.259-266
    • /
    • 2021
  • USB 버스는 편리하게 사용할 수 있고 빠르게 데이터를 전송하는 장점이 있어서, FPGA 개발보드와 PC 사이의 표준적인 인터페이스이다. 본 논문에서는 Cypress FX3 USB 3 브릿지 칩에 대한 slave FIFO 인터페이스를 사용하여 FPGA 검증 시스템을 구현하였다. slave FIFO 인터페이스 모듈은 FIFO 구조의 호스트 인터페이스 모듈과 마스터 버스 제어기와 명령 해독기로 구성되며, FX3 브릿지 칩에 대한 스트리밍 데이터 통신과 사용자 설계 회로에 대한 메모리 맵 형태의 입출력 인터페이스를 지원한다. 설계 검증 시스템에는 Cypress FX3 칩과 Xilinx Artix FPGA (XC7A35T-1C5G3241) 칩으로 구성된 ZestSC3 보드가 사용되었다. C++ DLL 라이브러리와 비주얼 C# 언어를 사용하여 개발한 GUI 소프트웨어를 사용하여, 사용자 설계 회로에 대한 FPGA 검증 시스템이 다양한 클록 주파수 환경에서 올바로 동작함을 확인하였다. 설계한 FPGA 검증 시스템의 slave FIFO 인터페이스 회로는 모듈화 구조를 갖고 있어서 메모리맵 인터페이스를 갖는 다른 사용자 설계 회로에도 응용이 가능하다.

Estelle로 기술된 프로토콜의 적합성 검증에 관한 연구 (A study on the Conformance Test for Protocols Written in Estelle)

  • 인소란;원유훈
    • 전자공학회논문지B
    • /
    • 제29B권11호
    • /
    • pp.1-7
    • /
    • 1992
  • The conformance test is a methodology which verifies whether the Implementation Under Test (IUT) conforms to its standard specification or not. In this paper, first, the Conformance Test System(CTS) is implemented in prototype including verification test type, black-box test strategy, conformance test class, remote test structure, and IUT which is described by the ISO Estelle among Formal Description Techniques. Second, through this prototype the proposed system is experimented. The prototype is composed of two modules. The first module is the Estelle-to-Pascal preprocessor which converts the Estelle program to the corresponding Pascal program because the experimental IUT was described using the unexecutable code form of Estelle before being tested by the TD(Test Driver). The TD, the second module, is based on the master-slave concept and plays important role is CTS. The TD acts as the master with the IUTd being the slave. The prototype system is implemented using Turbo-C, Turbo-Pascal and Turbo-Assembly.

  • PDF

근거리 원격 계측 및 제어를 위한 다중 PLC용 통신 모듈 개발 (A development of multiple PLC communication module for near field control and measurement)

  • 박종석;현웅근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.661-664
    • /
    • 2000
  • A winless communication module for multiple PLC was developed. The function of the developed system are dual communication, concurrent multiple communication PLC control ,d interpretation of RC command, and A/D D/A converting. The multiple communication approach is based on master-slave control concept To show validity of the developed module, severial experiments are illustrated.

  • PDF

다중 무선 제어용 PLC 통신 모듈 개발 (A multiple wireless communication module for PLC controller)

  • 박종석;현응근;유춘식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2423-2425
    • /
    • 2000
  • A wireless communication module for multiple PLC was developed. The function of the developed system are dual communication, concurrent multiple communication. PLC control, d interpretation of PLC command, and A/D D/A converting. The multiple communication approach is based on master-slave control concept. To show validity of the developed module, severial experiments are illustrated.

  • PDF

에너지 절감을 위한 무선 대기전력 제어 시스템 설계 및 구현 (Design and Implementation of Wireless standby Power Control System for Energy Saving)

  • 심갑식;장재혁
    • 한국콘텐츠학회논문지
    • /
    • 제13권5호
    • /
    • pp.19-27
    • /
    • 2013
  • 본 논문에서는 마스터 장치와 슬레이브 장치로 구성된 대기 전력 제어 시스템을 구현한다. 마스터 장치의 RFID 카드의 인증여부에 따라 슬레이브 장치의 릴레이를 제어한 후에 전원 공급을 차단함으로써 대기전력이 관리된다. 마스터 장치는 RFID 인터페이스 및 무선 통신 모듈을 내장하고 있고, 마스터 장치 1개에 대해 n개의 슬레이브 장치가 무선으로 연계되며 각각의 슬레이브 장치는 전력제어에 필요한 동작을 독립적으로 수행한다. 슬레이브 장치에 수동으로 전력을 on/off 할 수 있는 기능과 스위치 조작을 통해 마스터 장치에 사용자 ID를 등록하는 기능을 구현했다. 또한, 본 시스템은 무선으로 양방향 통신이 가능하고 TinyOS 상에서 실행된다. 실험 결과, 본 시스템은 마스터 장치에서 사용자 여부를 인식하고, 이에 대한 인식 정보를 무선 통신으로 슬레이브 장치에 전송함으로써, 릴레이를 제어하여 대기 전력이 차단된 것을 보여 주었다. 본 시스템을 건물이나 사무실에 설치할 경우 전력 절감을 기할 수 있다.

RF 모듈 방식의 선박용 냉동 컨테이너 원격 감시시스템 개발 (Development of Refer-container Remote Monitoring System for Ship using RF Module)

  • 양현숙;임현정;김건우;권영괄;김동묵;이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.425-432
    • /
    • 2007
  • This paper describes a development of ship's refer-container remote monitoring system(RRMS). This system consists of Master, repeater with a switched mode power supply(SMPS) and slave terminal. Slave terminal is composed of wireless MODEM and microprocessor part, checks its conditions like temperature. humidity & etc through the interrogate port(IP) of refer-container. and transmits their data to master. Repeater's role is that connect so that signal which is transmitted from Slave Terminal by Master may not receive electric wave interference by container boxes. We verify the effectiveness of proposed system through the experimental works in container yard and ship.