• Title/Summary/Keyword: Skull image

Search Result 142, Processing Time 0.021 seconds

Top Design by Skull Image for Female Teenagers (해골 이미지를 응용한 여자 청소년 상의(Top)디자인)

  • Ryu, Kyoung-Ok
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.123-130
    • /
    • 2012
  • The purpose of this study is to understand Skull Images in fashion trends and Skull Image Top Design for Female Teenagers. The methods of this study are an academic literature review as well as practical study through actual case studies about. The subjects of the study were 53 Female Teenagers who lived in Chuncheon. Data were collected during March, 2009. Statistical analyses used in the study were frequency. An adolescent period, they are rebellious, sensual and syntonic inclination. These days, Lots of Female Teenagers want unique fashion for herself and select Skull Image clothing. But they want fit and pretty style not big-look. In this study, I designed seven pieces of Top blouse while applying Skull Image, an important image of Hip-hop and Punk fashion, and the concepts of the continuance theory to them. This study will make a contribution to the designing of Top for Female Teenagers through reinterpretation of the Hip-hop and Punk fashion. In addition, there are practicable and unique Top design for Female Teenagers.

  • PDF

Image Superimposition for the Individual Identification Using Computer Vision System (컴퓨터 시각 인식 기법을 이용한 영상 중첩법에 의한 개인식별)

  • Ha-Jin Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.37-54
    • /
    • 1996
  • In this thesis, a new superimposition scheme using a computer vision system was proposed with 7 pairs of skull and ante-mortem photographs, which were already identified through other tests and DNA fingerprints at the Korea National Institute of Scientific Investigation. At this computer vision system, an unidentified skull was caught by video-camcoder with the MPEG and a ante-mortem photograph was scanned by scanner. These two images were processed and superimposed using pixel processing. Recognition of the individual identification by anatomical references was performed on the two superimposed images. These results were as followings. 1. For the enhancement of skull and ante-mortem photographs, various image processing schemes, such as SMOOTH, SHARPEN, EMBOSS, MOSAIC, ENGRAVE, INVERT, NEON and COLOR TO MONO, were applied using 3*5 window processing. As an image processing result of these methods, the optimal techniques were NEON, INVERT and ENGRAVE for the edge detection of skull and ante-mortem photograph. 2. Using various superimposition image processing techniques (SRCOR, SRCAND, SRCINVERT, SRCERASE, DSTINVERT, MERGEPAINT) were compared for the enhancement of image recognition. 3. By means of the video camera, the skull image was inputed directly to a computer system : superimposing it on the ante-mortem photograph made the identification more precise and time-saving. As mentioned above, this image processing techniques for the superimposition of skull and ante-mortem photographs simply used the previous approach, In other wrods, taking skull photographs and developing it to the same size as the ante-mortem photographs. This system using various image processing techniques on computer screen, a more precise and time-saving superimposition technique could be able to be applied in the area of individual identification in forensic practice.

  • PDF

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.

A Study on the Image Quality and the Scattered Ray content in the Skull Radiography (두부(頭部) X선촬영시(線撮影時) 산란선(散亂線)과 화질(畵質)에 관(關)한 검토(檢討))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Lee, Sun-Sook;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.15-19
    • /
    • 1985
  • The seattered-ray have a bad effect to the image of x-ray film. Therefore, to obtain the better x-ray image, the most important point is to eliminate the scattered-ray, come from the patient, and the easiest method to eliminate the scattered-ray is to use a proper grid for tube voltages. Authors made an experiment on the scattered-ray contents and the image quality in skull radiography, and obtained the results as follows; 1. The scattered-ray content in skull radiography was 83%, but it could be reduced to 35%-50% by using grid. 2. The image contrast was most increased when the using grid ratio was 8:1. 3. The image quality was not influenced by the scattered-ray contents between 32% and 45%.

  • PDF

A COMPARATIVE STUDY OF ANATOMIC STRUCTURES ON THE PANORAMIC RADIOGRAPH AND SOME EXTRAORAL RADIOGRAPHS (파노라마방사선사진상과 구외방사선사진상에서의 해부학적 구조에 관한 비교연구)

  • Lee Dong Kyu;Kim Han Pyoung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.71-80
    • /
    • 1984
  • The author has studied each landmark for successful interpretation in the radiograph of the head that have the complex anatomic structures, using panoramic radiograph, postero-anterior cephalometric radiograph, lateral cephalometric radiograph, Waters' radiograph of the skull. The anatomic structures of the human dry skull attached by radiopaque materials were taken radiographs and analysed comparatively. The results were as follows: 1. The overall anatomic structures of the mandible showed sharp images in the panoramic radiograph than other radiographs with relatively less distortion, superimposition, blurring of the image. 2. The anatomic structures were situated on sagital plane of the skull showed blurred images in panoramic radiograph than other radiographs. 3. The anatomic structures which were situated on the basal portion of the skull showed blurred and secondary images in the panoramic radiograph than other radiographs. 4. In the panoramic radiograph, the lower 3rd portion of the orbit appeared to be superimposed with the superior portion of the maxillary sinus and the medial and lateral surface of the nasal cavity showed extensively superimposition of the orbit and the maxillary sinus, which images showed blurring. 5. The inferior surface and posterior surface of maxillary sinus showed to be good image in the panoramic radiograph than other radiographs. 6. In the panoramic radiograph, line of maxillary bone between lateral pterygoid plate, line of maxillary bone between zygomatic bone showed distinct image with another structures.

  • PDF

Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model (전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Lee Byeong-Do;Lee Wan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

Alveolar Soft Part Sarcoma Metastasized to Both the Skull and the Brain

  • Shin, Tae-Hee;Jung, Young-Jin;Kim, Oh-Lyong;Kim, Min-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.1
    • /
    • pp.55-57
    • /
    • 2012
  • Alveolar soft part sarcoma (ASPS) with skull and brain metastases is extremely rare. A 53-year-old patient diagnosed as skull metastasis of ASPS visited our clinic complaining of an outgrowing scalp mass in spite of radiation therapy. Past medical history revealed that the patient had been diagnosed and treated for ASPS of the thigh 4 years ago. Magnetic resonance imaging revealed a hyperintense ovoid mass on the T2-weighted image, an isointense on the T1-weighted image, and a homogeneous enhanced mass with gadolinium. Another small-sized enhanced mass with mild peritumoral swelling was found at the deep white matter of the left frontal lobe. A gross total resection of the skull lesion with cranioplasty was performed for the surgical defect. A histologic examination of the specimens revealed metastatic ASPS involving the skull. Surgery with a total removal of the lesions may be effective for improving a patient's symptoms especially from neurological dysfunction.