• Title/Summary/Keyword: Skin implants

Search Result 48, Processing Time 0.022 seconds

Absorbed and effective dose from spiral and computed tomography for the dental implant planning (치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가)

  • Hong Beong-Hee;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

Reconstruction of Combined Oral Mucosa-Mandibular Defects Using the Vascularized Myoosseous Iliac Crest Free Flap

  • Jung, Hwi-Dong;Nam, Woong;Cha, In-Ho;Kim, Hyung Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4137-4140
    • /
    • 2012
  • The authors present five cases of combined oral mucosa-mandible defects reconstructed with the vascularized internal oblique-iliac crest myoosseous free flap. This technique has many advantages compared to other conventional methods such as the radial flap, scapula flap, and fibula flap. Vascularized iliac crest flaps provide sufficient high-quality bone suitable for reconstructing segmental madibular defects. Although fibular flaps allow longer donor bone tissue to be harvested, the iliac crest can provide an esthetic shape for mandibular body reconstruction and also provides sufficient bone height for dental implants. Conventional vascularized iliac crest myoosseous flaps have excessive soft tissue bulk for reconstruction of intraoral soft tissue defects. The modification discussed in the present article can reduce soft tissue volume, resulting in better functional reconstruction of the oral mucosa. Another advantage is that complete replacement of the oral mucosa is observed in as early as one month post-operation. The final mucosal texture is much better than that obtained with other skin paddle flaps, which is especially beneficial for the placement of dental implant prostheses. Donor site morbidity looks to be similar to, if not less than that observed for other modalities in terms of function and esthetics. For combined oral mucosa-mandible defects, the vascularized internal oblique-iliac crest myoosseous free flap shows good results with respect to hard and soft tissue reconstruction.

Case Report : Latissimus Dorsi Flap for Secondary Breast Reconstruction after Partial TRAM Flap Loss (유경 횡복직근피판술 후 발생한 부분 피판괴사 및 지방괴사의 넓은등근피판을 이용한 재건 치험례)

  • Song, Jae Min;Yang, Jung Duk;Lee, Sang Yun;Jung, Ki Ho;Jung, Ho Yun;Cho, Byung Chae
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: The transverse rectus abdominis musculocutaneous(TRAM) flap is the most commonly used autogenous tissue flap for breast reconstruction. Postoperatively, partial flap loss or fat necrosis are relatively common and it may result in a smaller breast volume with marked contour irregularities. These defects are not easy to reconstruct with local tissue rearrangement or with breast implants. The current authors present the results of 2 patients who underwent Latissimus dorsi(LD) flap reconstruction to correct partial flap or fat necrosis that developed after TRAM flap breast reconstruction. Method: Case1: A 50 - year - old woman with left breast cancer visited for breast reconstruction after radical mastectomy. Initially, breast reconstruction with pedicled TRAM was performed. Postoperatively partial flap necrosis was developed. Secondary breast reconstruction using LD flap was done. Case2: A 51 - year - old woman with left breast cancer visited for breast reconstruction after radical mastectomy. Initially, breast reconstruction with pedicled TRAM was performed. Postoperatively fat necrosis was developed. Secondary breast reconstruction using LD flap was done. Results: Secondary breast reconstruction using LD flap survived completely and produce successful reconstruction. There was no significant complication in both patients. Conclusion: LD flap provides sufficient, vascularized skin and soft tissue. The flap can be molded easily to replace deficient tissue in all areas of the breast. These attributes make it an ideal candidate for salvage of the partially failed TRAM flap breast reconstructio.

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Artificial Trachea Covered by Ipithelium (상피세포 피복 인공기관의 개발)

  • 김광택;이윤신
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.739-746
    • /
    • 1997
  • A variety of experiments concerning the development of ideal prosthetic grafts for correcting circumferential tracheal defects have been performed. The requirements for an ideal tracheal prosthesis are impermeability to air, consistency to prevent collapse, and acceptance by the host tissue causing a minimum inflammatory reaction, allowing fibroblastic infiltration and epithelialization. The synthetic material, polyurethane(PU), is known as a biocompatible polymer with an inert component. In this study, the tracheal prosthesis was made from microporous PU(30 micrometer in diameter) coated with gelatin and reinforced with isoplastic rings. This procedure provides the prosthesis with a compression strength. The out side diame er of the prosthesis was 20 mm with a length of 30 mm. The gelatin used in the study was obtained from pig skin and immobilized and cross-linked by irradiation(60 Co gamma ray) to promote host tissue incorporation and render the prosthesis epithelization after implantation. Animal experiments using 10 mongrel dogs were performed to compare three kinds of prosthesis; gelatin coated polyurethane graft, uncoated polyurethane graft, and prosthesisf pericadium complex graft. After 6 weeks of implantation, the epithelialization of implants was seen on the gelatin-coated and prosthesisfpericadium complex grafts. Implanted prosthesis were complicated by airway obstruction due to anastomosis granuloma. Early tracheal stenosis was found in the uncoated graft group. Two kind of anastomosis techniques were tested on the gelatin-coated prosthesis. Everted anastomosis resulted severe granuloma than the inverted anastomosis. In the prosthesislpericadium complex graft, bacteria and inflammation at a anastomotic site was found. Based on these results, gelatin coated porous polyurethane trachea prosthesis is biocompatible and may be useful in clinical application with further investigation.

  • PDF

Transareolar-Perinipple Dual Pockets Breast Augmentation (횡유륜 유두주위절개를 통한 이중포켓 유방확대술)

  • Lee, Paik Kwon;Kim, Jee Hoon;Seo, Byung Chul;Oh, Deuk Young;Rhie, Jong Won;Ahn, Snag Tae
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.93-98
    • /
    • 2007
  • Purpose: Many options are available for the incision and pocket selection in breast augmentation. Each method has its advantages and disadvantages. To leave an invisible operation scar and to achieve easier pocket dissection by the central location of the incision on the breast, we made a transareolar-perinipple incision. To overcome the disadvantages of the transareolar incision, originally advocated by Pitanguy in 1973, we modified the direction of incision line and dissection plane. Methods: To avoid the injury of 4th intercostal nerve responsible for nipple sensation, we made perinipple incision on the medial side of the nipple instead of trans-nipple incision and made the transareolar incision as 11-5 o'clock on the left side and 1-7 o'clock on the right side instead of 3-9 o'clock on both sides. To avoid the possible infection and breast feeding problem caused by the injury to the lactiferous duct, and the possible implant hernia caused by the incisions lying on a same plane of pocket dissection, we made a subcutaneous dissection just above the breast tissue medially down to the bottom of breast tissue and made a subglandular or subfascial pocket, which may avoid the injury of lactiferous duct and create different planes for skin incision and pocket dissection. Other advantages of the transareolar-perinipple incision include easier pocket dissection, less chance of hematoma, and as a result less postoperative pain because of the central location of the approach which allow finger dissection and meticulous bleeding control with direct vision, without any specialized instrument such as an endoscope or long mammary dissectors. As for pocket selection, we made dual pockets. We prefer subglandular or subfascial pocket. Also, we made a subpectoral pocket in the upper 1/4 of the pocket to add more volume on the upper part of the augmented breast, which can make aesthetically more desirable breasts in thin Asian women with small breasts. Possible disadvantages of our method are subclinical infection and scar widening, which could be overcome by meticulous operation techniques, antibiotic therapy, and intradermal tattooing. Results: From September, 2003 to August, 2005, 12 patients underwent breast augmentation using round smooth surface saline implants by our method. During the mean follow-up period of 13 months, there were no complications such as infection, hematoma, capsular contracture, and sensory change of nipple, and results were satisfactory. Conclusion: We suggest breast augmentation via transareolar-perinipple incision and dual pockets(subpectoral-subglandular or subfascial) as a valuable method in thin oriental women with small breasts.

Immediate breast reconstruction following nipple-sparing mastectomy in an Asian population: Aesthetic outcomes and mitigating nipple-areolar complex necrosis

  • Pek, Wan-Sze;Tan, Bien-Keem;Ng, Yvonne Ying Ru;Tan, Veronique Kiak Mien;Rasheed, Mohamed Zulfikar;Tan, Benita Kiat Tee;Ong, Kong Wee;Ong, Yee Siang
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.229-238
    • /
    • 2018
  • Background Nipple-sparing mastectomies (NSMs) are increasingly performed to obtain the best aesthetic and psychological outcomes in breast cancer treatment. However, merely preserving the nipple-areolar complex (NAC) does not guarantee a good outcome. Darkly pigmented NACs and a tendency for poor scarring outcomes are particular challenges when treating Asian patients. Herein, we review the reconstructive outcomes following NSM at Singapore General Hospital. Methods All breasts reconstructed following NSM over an 11-year period from 2005 to 2015 were reviewed. Information was collected from the patients' records on mastectomy indications, operative details, and complications. Patient satisfaction, breast sensation, and aesthetic outcomes were evaluated in 15 patients. Sensation was quantified using the Semmes-Weinstein monofilament test. Results A total of 142 NSMs were performed in 133 patients for breast cancer (n=122, 85.9%) or risk reduction (n=20, 14.1%). Of the procedures, 114 (80.2%) were autologous reconstructions, while 27 (19.0%) were reconstructions with implants. Complications occurred in 28 breasts (19.7%), with the most common complication being NAC necrosis, which occurred in 17 breasts (12.0%). Four breasts (2.8%) had total NAC necrosis. The overall mean patient satisfaction score was 3.0 (good). The sensation scores were significantly diminished in the skin envelope, areola, and nipple of breasts that had undergone NSM compared to non-operated breasts (P<0.05). Half of the subset of 15 patients in whom aesthetic outcomes were evaluated had reduced nipple projection. Conclusions Immediate reconstruction after NSM was performed with a low complication rate in this series, predominantly through autologous reconstruction. Patients should be informed of potential drawbacks, including NAC necrosis, reduced nipple projection, and diminished sensation.